Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUB - SITE and/or GRADING
Permit Number - DP13-0115
Review Name: RESUB - SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/16/2014 | RONALD BROWN | HC SITE | REVIEW | Reqs Change | 1. Provide a large scale detail of the new entrance stair and ramp area showing all accessibility requirements such as dimensions, handrails for both stairs and ramp, grade elevations, slope percentages, riser and tread sizes, handrail elevations, landings and door locations and swing positions. 2. Please add an accessible passenger loading zone as per ICC A117.1, Section 403 which requires an 8'x20' vehicle pull space outside the 24' wide PAAL and a 5'x20' aisle connected to an accessible route. Slope side walk down to be flush with asphalt for a distance of 20' and then slope back up to curb height. 3. As per the 2012 IBC, Section 1104.1, the new pedestrian route to Camilia must be accessible. Provide detectable warning strips at both ends of all the marked crossings from Camilia as per 2009 ICC A117.1, Sections 3406.12, 13 and 14 as applicable. 4. Reference suggested changes to accessible routes and marked crossings for a simpler and efficient route as shown on sketch overlay on drawing, suggested only. END OF REVIEW |
| 01/17/2014 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | Ensure that all Zoning comments and concerns are addressed prior to Landscape approval of entire DP |
| 12/24/2013 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Planning and Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Loft Cinema Development Package (2nd Review) DP13-0115 TRANSMITTAL DATE: December 24, 2013 DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Unified Development Code (UDC), Administrative Manual (AM) & Technical Standards Manual (TSM) were addressed. 1. This site was reviewed for full code compliance for the entire site. The following comments are based on the requirements of Administrative Manual (AM) 2-06.0. Development package review comments; 1. This comment has not been addressed. A.M. 2-06.4.9.E As this project is comprised of four (4) parcels, 122-17-276E, 122-17-278B, 122-17-283C & 122-17-2820 a lot combination is required. Provide a copy of the approved Pima County Combo Request form with the next submittal. 2. A.M. 2-06.4.9.H.d Keynote 20 shows "DETAIL G, SHEET 3" there is no detail G on sheet 3. 3. A.M. 2-06.4.9.H.d Provide the 4 foot clear dimension between racks on detail G sheet 4, see UDC Figure 7.4.9-C. 4. A.M. 2-06.4.9.R Per TSM 7-01.4.1.A Provide a dimension between bicycle parking spaces, see redline detail G sheet 4, as this is a required sidewalk connection from the eastern most building to Camilla Blvd. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov Sshield1 on DS1/planning/New Development Package/ DP13-0115 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/21/2014 | CPIERCE1 | REJECT SHELF | Completed |