Permit Review Detail
Review Status: Completed
Review Details: SITE and/or GRADING
Permit Number - DP13-0108
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/24/2013 | RBROWN1 | ADA | REVIEW | Passed | |
| 06/25/2013 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
| 06/28/2013 | JASON GREEN | ENGINEERING | REVIEW | Reqs Change | DATE: July 3, 2013 SUBJECT: Commercial Parking Lot Development Plan Package- Engineering Review TO: David Chen LOCATION: 2318 & 2320 S Campbell Ave; T14S R14E Sec19 REVIEWERS: Jason Green, CFM ACTIVITY: DP13-0108 SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the proposed Development Plan Package. Engineering Division does not recommend approval of the Development Plan Package at this time. This review falls under the Unified Development Code (UDC), Administration Manual (AM) and Technical Standards Manual (TSM). Refer to the links for further clarification: http://cms3.tucsonaz.gov/files/planning/UDC_ADOPTED_100912.pdf; http://cms3.tucsonaz.gov/files/planning/Technical_Manual_ADOPTED_100912.pdf; http://cms3.tucsonaz.gov/files/planning/Admin_Manual_ADOPTED_100912.pdf The following items need to be addressed: SITE PLAN: 1) AM Sec.2-06.3.12: Revise the development plan document and Sheet count to read Sheet 1 of 4, currently the plan set has multiply sheets labeled as CS-1 and the landscape sheets only go to Sheet 3. 2) AM Sec.2-06.4.9.H.5.a: Revise the development plan documents to label the height of the proposed extruded curbing. Minimum curbing is to be 6-inches, provide a PC/COT Standard Detail reference or a separate detail for construction purposes. 3) AM Sec.2-06.4.9.H.5.a: Revise the development plan documents to provide the minimum dimensions and radii for the required back-up spur at the end of the PAAL per UDC Sec.7.4.6.F.4. Specifically the required 3-foot radii, 3-foot space from curb to parking stall and verify the 3-foot clear space if there is any barrier over 6-inches in height. 4) AM Sec.2-06.4.9.H.5.a: Revise the development plan documents to provide the minimum 24-foot PAAL width the entire length of the parking area that accesses a parking stall. 5) AM Sec.2-06.4.9.R: Revise the development plan document and associated proposed sidewalk to reference the PC/COT Standard Detail #200 for Public or provide a separate detail for construction purposes. 6) AM Sec.2-06.4.9.R: Refer to comments from Ron Brown, RA Structural Plans Examiner for all handicap accessibility comments that may be associated with this project. GENERAL COMMENTS: Please provide a revised Development Plan Package that addresses the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. For any questions or to schedule meetings call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Planning & Development Services Department |
| 07/02/2013 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Revise the site drawing to include the following information: a. The location, invert and rim elevations of the upstream and downstream sanitary sewer manholes; along with the Pima County Wastewater Management Department (PCWMD) reference number. b. The first floor elevation for the building Reference: City of Tucson Administrative Manual No. 2-06.0.0, Section 4.8 and Section 107.2.13, IBC 2012. |
| 07/09/2013 | RONALD BROWN | H/C SITE | REVIEW | Passed | No accessibility requirements - Exsiting Residental |
| 07/15/2013 | JOE LINVILLE | LANDSCAPE | REVIEW | Passed | |
| 07/18/2013 | TERRY STEVENS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Terry Stevens Lead Planner PROJECT: DP13-0108 2318 S. Campbell Ave Developmet Package TRANSMITTAL DATE: 07/18/2013 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. AM Sec.2-06.3.12: Revise the development plan document and Sheet count to read Sheet 1 of 4, currently the plan set has multiply sheets labeled as CS-1 and the landscape sheets only go to Sheet 3. 2. AM Sec.2-06.4.9.H.5.a: Revise the development plan documents to provide the minimum dimensions and radii for the required back-up spur at the end of the PAAL per UDC Sec.7.4.6.F.4. Specifically the required 3-foot radii, 3-foot space from curb to parking stall and verify the 3-foot clear space if there is any barrier over 6-inches in height. 3. AM Sec.2-06.4.9.H.5.a: Revise the development plan documents to provide the minimum 24-foot PAAL width the entire length of the parking area that accesses a parking stall. 4. AM Sec.2-06.4.9.R Clearly indicate that the pedestrian circulation path (sidewalk) from the right of way to each unit's entrance is a minimum of 4' in width and constructed of concrete. 5. The above comments are minor and can be reviewed over the counter by setting an appointment with me or other reviewers. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 |
| 07/23/2013 | JOE LINVILLE | NPPO | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/25/2013 | CPIERCE1 | REJECT SHELF | Completed |