Permit Review Detail
Review Status: Active
Review Details: GRADING
Permit Number - DP13-0090
Review Name: GRADING
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/13/2013 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | Since special conditions exist at this site, all grading must conform to engineered grading. (TSM 2-01.4.1.B) Provide a complete site and grading plan as part of the development package. The contents must include all of the required elements of the TSM. Clearly define the site for purposes of this permit. If this grading was performed to support the use of an adjacent or nearby parcel, the whole use area must be included in the Provide correct addressing information including correct parcel identification. Provide a complete grading plan including all of the elements listed in the Technical Standard. (TSM 2-01.4.1.C) Provide the required soils engineering report and engineering geology report and incorporate the recommendations in the grading plan. (TSM 2-01.4.1.D and E and C.6) A stormwater pollution prevention plan is required and the erosion and sediment controls must be maintained until full stabilization of the site is achieved. Note that a new general permit has been issued by ADEQ and the SWPPP must conform to this new permit. |
| 06/13/2013 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | June 13, 2013 Development Services Department Zoning Review Section Michael St.Paul Planning Technician DP13-0090 Grading Plans for ? Address: 4555 South Mission Road (incorrect address parcel 119-42-006F) Comments: 1. Provide a correct address for parcel 119-42-006F. The address provided is for parcel 119-42-006J. If the grading is for the addressed site, combine the two parcels into one parcel and develop this as one site. 2. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 3. In addition, we could not verify that the grading plan was in compliance with the approved development plan for Zoning Review. Such a plan is required. Also, aerial photos are not plans. Please submit one copy of the approved and stamped Development Plan, Landscape, and NPPO plans with the next grading plan submittal. 4. Provide the Development Package numbers for this grading plan and the related Development Package. 5. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved development plan. Additional comments may be forthcoming. |
| 06/21/2013 | ANDREW CONNOR | NPPO | REVIEW | Denied | 1. Provide the correct address of site. 2. No person shall do any grubbing on any site or portion thereof without first having obtained a grading permit from PDSD. No grubbing shall occur on any land except where grading has been approved UDC 2-102.1.A. 3. No grubbing, grading, construction, or salvaging of any plants on the site may take place prior to the submittal and approval of the required Native Plant Preservation Plan. 4. No grubbing, grading, construction, or salvaging of any plants on the site may take place prior to the submittal and approval of the required Native Plant Preservation Plan. 5. Submit a Native Plant Preservation Plan consisting of information itemized below according to the preservation and mitigation methodology chosen by the applicant. Additional information may be required by the PDSD Director in order to ensure that the General Provisions and Requirements of the Native Plant Preservation ordinance, Section 7.7.4 of the UDC, are fulfilled. 6. Ensure that all Engineering and Zoning comments and concerns are addressed. 7. Additional comments will apply |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/24/2013 | CPIERCE1 | REJECT SHELF | RECEIVED |