Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP13-0055
Parcel: 13101002H

Address:
5000 E 29TH ST

Review Status: Completed

Review Details: SITE and/or GRADING

Permit Number - DP13-0055
Review Name: SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/09/2013 ANDREW CONNOR LANDSCAPE REVIEW Approved
04/10/2013 ANDREW CONNOR NPPO REVIEW Approved
04/17/2013 RBROWN1 ADA REVIEW Denied GENERAL
1. Please note that all new accessible route slopes are to comply with the 2010 ADASAD, Section 403.3, 5% maximum running and 2% cross.
SHEET P2
2. Please call out Loading Dock at the swimming pool building.
SHEETS P-1 THROUGH P-5
3. Please provide marked crossings from the North portion of the site to the South portion of the site connecting all new accessible routes.
SHEET P-6
4. At detail 14:
a. Delete the ramp reference to COT STD Detail 207. Please reference 2010 ADASAD, Sections 405 and 406 as applicapable.
b. Delete the detectable warning strips. They are not required.
5. At detail 12:
a. Call out 2% maximum grade slopes in all directions.
b. Provide "Van Accessible" accessible parking space dimensions.
6. Delete detail 16, it is not required.
END OF REVIEW

Final Status

Task End Date Reviewer's Name Type of Review Description
04/24/2013 FERNE RODRIGUEZ OUT TO CUSTOMER Completed