Permit Number: DP13-0053
Parcel: 133341210

Review Status: Completed

Review Details: DEV PKG - REVISION

Permit Number - DP13-0053
Review Name: DEV PKG - REVISION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/10/2014 SPOWELL1 START PLANS SUBMITTED Completed
04/10/2014 RONALD BROWN ADA REVIEW Passed
04/11/2014 STEVE SHIELDS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: A-Family Discount Self Storage - 8950 E. Speedway Blvd
Development Package (Revision)
DP13-0053


TRANSMITTAL DATE: April 11, 2014

DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Unified Development Code (UDC), Administrative Manual (AM) & Technical Standards Manual (TSM) were addressed.

1. The Zoning Review Section conditionally approves the development package for this project subject to the following documentation being supplied to the CDRC office.

2. As this site is comprised of two (2) parcels a lot combination is required. Provide a copy of the approved Pima County Combo Request form. Zoning will not approve any building plans for building that cross over the existing alley and/or existing property lines until this combo is complete.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov
04/28/2014 ANDREW CONNOR LANDSCAPE REVIEW Approved
04/28/2014 LAITH ALSHAMI ENGINEERING REVIEW Approved Laith Alshami, Engineering and Floodplain Review, 04/28/2014,

SUBJECT: A-Family Discount Self Storage
DP13-0053, T14S, R15E, SECTION 10

RECEIVED: Development Package on April 09, 2014

The subject project has been reviewed. The revised Development Package is acceptable and hereby approved pertaining to Engineering and Floodplain Review.

If you have any questions, I can be reached at 837-4933 or Laith.Alshami@tucsonaz.gov
04/30/2014 RONALD BROWN HC SITE REVIEW Reqs Change The reason the accessible parking space was placed at Building 21 was to reduce the requirements of having an accessible route to a far away location requiring marked crossings at every PAAL crossing and (as per zoinng requirements) 4' concrete walkways in lieu of 2' pedestrian refuge areas.
a. Please provide an accessible route from the accessible space located East of Building 18 along with marked crossings at each PAAL crossing location to the accessible route located at the Main Office. Confirm with Zoning their rquirements for a 4' wide concrete pedestrian walkway.
END OF REVIEW
04/30/2014 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702

WR#272122 April 29, 2014

Sierra Land Surveying
Attn: Russell Shaw
PO Box 1569
Oakhurst, CA 93644

Dear Mr. Shaw :

SUBJECT: A-Family Discount Self Storage
DB13-0053

Tucson Electric Power Company has reviewed and approved the development plan submitted April 22, 2014. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans.

If easements are required, they will be secured by separate instrument. Your final plans should be sent to:
Tucson Electric Power Company
Attn: Mr. Richard Harrington
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8726

Should you have any technical questions, please call the area Designer Chuck Leon at (520) 917-8707.

Sincerely,


Jeffery Shea
Admin Support Specialist
Design/Build
lm
Enclosures
cc: DSD_CDRC@tucsonaz.gov, City of Tucson (email)
C. Leon, Tucson Electric Power
05/07/2014 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal/walk-thru is required to deal with the remaining comments.

Items needed include:

1) Two rolled sets of the plans
2) All items requested by review staff
3) All itmes needed to approve this plan/revision

Final Status

Task End Date Reviewer's Name Type of Review Description
05/07/2014 CPIERCE1 REJECT SHELF Completed