Permit Number: DP13-0053
Parcel: 133341210

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP13-0053
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/16/2013 SPOWELL1 START PLANS SUBMITTED Completed
09/10/2013 RONALD BROWN ZONING HC REVIEW Approved
09/11/2013 STEVE SHIELDS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: A-Family Discount Self Storage - 8950 E. Speedway Blvd
Development Package (3rd Review)
DP13-0053


TRANSMITTAL DATE: September 11, 2013

DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Unified Development Code (UDC), Administrative Manual (AM) & Technical Standards Manual (TSM) were addressed.

1. The Zoning Review Section conditionally approves the development package for this project subject to the following documentation being supplied to the CDRC office.

2. Provide copies of the recorded documents to PDSD CDRC so that they can be placed in SIRE. A.M. 2-06.4.9.I Provide the recordation information for the proposed abandonment of the alley on the plan. The abandonment must be completed prior to approval of this development package.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov
09/16/2013 LAITH ALSHAMI ENGINEERING REVIEW Approv-Cond Laith Alshami, Engineering and Floodplain Review, 09/16/2013,

SUBJECT: A-Family Discount Self Storage
DP13-0053, T14S, R15E, SECTION 10

RECEIVED: Development Package on August 16, 2013

The subject submittal has been reviewed. Engineering and Floodplain Review Section conditionally approves the development package subject to providing copies of the recorded alley right of way abandonment documents to PDSD CDRC in order to scan them into SIRE. A.M. 2-06.4.9.I. Additionally, provide the recordation information for the proposed abandonment of the alley on the plan. The abandonment must be completed prior to approval of this development package.

If you have any questions, I can be reached at 837-4933 or Laith.Alshami@tucsonaz.gov

RESUBMITTAL REQUIRED: Alley abandonment documents and Revised Development Plan Package
09/16/2013 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change Include with the development package submittal the landscape screening plans approved with Case # T13SA00157.

Revise or remove CMU wall detail on sheet 4 of 16 of the development package.
09/17/2013 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond

Final Status

Task End Date Reviewer's Name Type of Review Description
09/18/2013 FERNE RODRIGUEZ OUT TO CUSTOMER Completed