Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP13-0041
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/12/2013 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 06/24/2013 | TERRY STEVENS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: DP13-0041 718 E. Graybill Dr. Development Package TRANSMITTAL: 07/05/2013 DUE DATE: 07/11/2013 COMMENTS: 1. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is 03/11/2014. 2. AM 2-06.4.2 The title block shall include the following information and be provided on each sheet: B. A brief legal description 3. AM 2-06.4.4 The project-location map to be located on the first sheet of the development package in the upper right corner, shall cover approximately one (1) square mile, be drawn at a minimum scale of 3" = 1 mile, and provide the following information. C. section corners will be labeled. 4. AM 2-06.4.7.A.3 Provide elevation drawings of the north wall clearly indicating compliance with rezoning condition #13. Letter from Mr. Duarte not included in submittal. Provide on the plans showing compliance with rezoning conditions #12. Clearly indicate on the plans the width of the existing and proposed masonry walls. Provide on the plans showing compliance with rezoning conditions #18. Provide the recording sequence number 20131500800 on the plan for the one foot NAE. Bk and page are incorrect. 5. AM 2-06.4.9.H.5.a Provide a dimensioned detail of a proposed vehicle parking space. See UDC Sec. 7.4.6.D Provide a cross reference from the site plan to the detail. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 |
| 07/08/2013 | LAITH ALSHAMI | ENGINEERING | REVIEW | Denied | Laith Alshami, Engineering and Floodplain Review, 07/09/2013, SUBJECT: Environmental Control of Tucson Storage Yard DP13-0041, T13S, R14E, SECTION 30 RECEIVED: Development Package on June 12, 2013 The subject submittal has been reviewed. The project shall be recommended for approval once the following comments have been satisfactorily addressed. Prepare a detailed response that explains the revisions that were made and references the exact location on the Development Package where the revisions were made: Development Package: 1. Indicate existing site ground elevations based on COT Datum (A.M. 2-06.4.8.E). Provide few spot elevation at the parcel corners and in the middle to satisfy this requirement 2. If grading is not proposed, what is the purpose of the 'Paving and Grading Notes"? Additionally, grading work shall conform to Technical Standard 2-01.0 (Excavation and Grading); not Development Standard 11-01. as stated in the first "Paving and Grading Note" provided on Sheet 1 of 5. If you have any questions, I can be reached at 837-4933 or Laith.Alshami@tucsonaz.gov |
| 07/11/2013 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | Revise the plan set as requested by other agencies. |
| 07/12/2013 | MICHAEL WYNEKEN | ZONING-DECISION LETTER | REVIEW | Denied | This review is complete and re-submittal is required. Submit two (2) sets of rolled plans with changes requested by reviewers, any additional items required by reviewers and any items required to approve the plans. |
| 07/12/2013 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 WR#264860 July 12, 2013 The Planning Center 110 S Church Suite 6320 Tucson, Arizona 85701 Dear Mr. Weier : SUBJECT: Environmental Control of Tucson DP13-0041 Tucson Electric Power Company has reviewed and approved the development plan submitted June 11, 2013. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Tucson Electric Power Company Attn: Mr. Richard Harrington New Business Project Manager P. O. Box 711 (DB-101) Tucson, AZ 85702 520-917-8726 Should you have any technical questions, please call the area Designer Jennifer Crawford at (520) 917-8708. Sincerely, Elizabeth Miranda Office Support Specialist Design/Build lm Enclosures cc: DSD_CDRC@tucsonaz.gov, City of Tucson (email) J. Crawford, Tucson Electric Power |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/06/2013 | CPIERCE1 | OUT TO CUSTOMER | Completed |