Permit Number: DP12-0227
Parcel: 12217001A

Review Status: Completed

Review Details: SITE and/or GRADING

Permit Number - DP12-0227
Review Name: SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/15/2013 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change 1. On sites where the gross floor area of the existing building(s) is ten thousand (10,000) square feet or less, expansions in square footage of land area, floor area, lot coverage, or vehicular use area the requirements of this Division apply only to the proposed expansion (Parking lot). LUC 3.7.1.2.B.2

2. A street landscape border, per Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress. Additional landscaping and screening is required to be installed on Speedway Blvd.

3. Street landscape borders shall be located entirely on site, except that, if approved by the City Engineer or designee, up to five (5) feet of the required ten (10) foot width be placed within the adjacent right-of-way area or within the Major Streets and Routes (MS&R) right-of-way area on MS&R streets.

4. A 30"continuous screen along street frontages for vehicle use area must be provided per LUC Table 3.7.2-I.

5. Include the following on the landscape plan.

" Location, size, and name of existing vegetation to remain in place.

" Both the proper and common name of each type of plant material.

6. Additional comments may apply
02/19/2013 ANDREW CONNOR NPPO REVIEW Approved
02/21/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
02/25/2013 PAUL MACHADO ENGINEERING REVIEW Denied To: AGCA, Inc. Attn: Anthony Capps DATE: Feb. 26, 2013
1373 W. Hopbush Way Tucson, Arizona 85704

Subject: Parking Lot at 3461 E. Speedway Blvd.
Development Package, DP12-0227 (First Review)
T14S, R14E, Section 04

RESUBMITTAL REQUIRED: Development Package/Site Plan (Plans may be walked through).

The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. General Notes. The following general notes are required. Additional notes specific to each plan are required where applicable. D.S. 2-01.3.7.
C. Streets and Roads Notes.
2. List the following note on all development package documents: "No structure or vegetation shall be located or maintained so as to interfere with the sight visibility triangles in accordance with Development Standard 3-01.0."
3. Existing Site Conditions. The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within fifty (50) feet of the site. D.S. 2-01.3.8.
C. The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks.
4. See additional "redline" comments for needed corrections. Also return the "redlines" with next submittal. The plans do not need to be submitted for engineering comments, I will review the plans at the counter if requested.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson - Planning and Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office, (520) 879-8010 fax, C:/3461 E. Speedway Blvd. DP-SP

Final Status

Task End Date Reviewer's Name Type of Review Description
03/01/2013 CPIERCE1 OUT TO CUSTOMER Completed