Permit Review Detail
Review Status: Completed
Review Details: SITE and/or GRADING
Permit Number - DP12-0211
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/26/2012 | SSHIELD1 | FIRE | REVIEW | Passed | |
| 12/26/2012 | SSHIELD1 | NPPO | REVIEW | Passed | |
| 12/26/2012 | SSHIELD1 | LANDSCAPE | REVIEW | Passed | |
| 12/26/2012 | SSHIELD1 | H/C SITE | REVIEW | Passed | |
| 12/26/2012 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Planning and Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Cricket Store @ 5147 S. 12th Avenue Development Package (2nd Review) DP12-0211 TRANSMITTAL DATE: December 26, 2012 DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. The proposed façade addition appears to be located within the future right-of-way, a temporary revolkable easement (TRE) or some other document may be required if the variance is approved. Contact COT Transportation Real Estate Department to verify requirements. The following comments are based on Development Standard 2-01.0: 1. D.S. 2-01.3.9.O Per LUC Section 3.2.6.5.B & Table 3.2.6.I the required street perimeter yard setback is 21' or the height of the proposed exterior building wall, which ever is greater. That said per Table 3.2.6.I, and an average daily traffic (ADT) of 1000 or greater, and a proposed wall height of less than 21', the required street perimeter yard setback is 21' measured from the back of future curb. Proposed street perimeter yard setback is 9'-10" If the Board of Adjustment for Variance is approved provide a General Note on the plan stating the Board of Adjustment Number, Date of Approval, What was Approved and any Conditions of Approval. Zoning is willing to provide an over the counter review once the above comments are addressed. Please call or email to schedule an appointment for this review. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com Sshield1 on DS1/planning/New Development Package/ DP12-0211 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package. |
| 12/26/2012 | SSHIELD1 | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 12/26/2012 | SSHIELD1 | ENGINEERING | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/27/2012 | SHANAE POWELL | OUT TO CUSTOMER | Completed |