Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: DP12-0209
Parcel: 99999999S

Address:
124 S CHERRY AV

Review Status: Completed

Review Details: SITE and/or GRADING

Permit Number - DP12-0209
Review Name: SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/15/2012 JASON GREEN ENGINEERING REVIEW Denied DATE: November 20, 2012
SUBJECT: South Cherry Residential Development Plan Package- Engineering Review
TO: Metro TED Attn: Lisa Bowers
LOCATION: 124 S Cherry St; T14S R14E Sec18; Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: DP12-0209


SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the proposed Development Plan Package. Engineering Division does not recommend approval of the Development Plan Package at this time. This review falls under Development Standard 2-01. All comments reflect Site Plan review. The following items need to be addressed:


SITE PLAN: It is recommended that Development Standard 2-01 "Development Package" be reviewed prior to resubmittal. DS Sec.2-02 and 2-05 no longer exists and all reviews fall under DS Sec.2-01 for Development Package. The standard has changes that must be incorporated into the plan sheets for review and approval.

1) DS Sec.2-01.3.2.D: Revise the development plan document to include the legal administrative address for the subject property.

2) DS Sec.2-01.3.3: The relevant Development Plan Package number (DP12-0209) may be added to the lower right hand corner of the plan on all sheets.

3) DS Sec.2-01.3.7: Either revise Keynote # 14 to include the following or provide separate note on Sheet 1 of the development plan document stating; "All retaining walls, proposed fencing and other walls will require a separate permit for review and approval by all necessary Planning Development Services Departments."

4) DS Sec.2-01.3.9.H.2: Revise the development plan document to correctly dimension the near side sight visibility for the PAAL to Local Street per DS Sec.3-01.5.3. The near side dimension for a PAAL intersecting a Local Street is 20'x185,' revise.

5) DS Sec.2-01.3.9.H.5.a: Revise the development plan documents to provide the minimum dimensions and radii for the proposed back-up spur per LUC 3.3.6.D.

6) DS Sec.2-01.3.9.H.5.a: Revise the development plan documents to provide the minimum radii dimensions for all proposed curbing within the vehicular use area.

7) DS Sec.2-01.3.9.M: Provide a copy of the Geotechnical Report that is referenced in the Earthwork and Materials Testing Note #1 on Sheet 3 of 6.

8) DS Sec.2-01.3.9.R: Revise Keynote #10 on the development plan document to reference the Sheet for the proposed concrete sidewalk detail C.

9) DS Sec.2-01.3.9.R: Revise the development plan document to verify that pedestrian circulation connects all buildings to all other areas of development, specifically to the proposed refuse enclosures per DS Sec.2-08.3.1.

10) DS Sec.2-01.3.9.T: Revise the development plan document to provide a construction detail for the refuse enclosures. The detail must match DS Sec.6-01 and Figure 3a (or b) for the required enclosure walls with gates, concrete thickness and compressive strength, concrete approach apron dimensions, 14'x40' clear approach for each container, etc.

11) DS Sec.2-01.3.9.T: Per DS Sec.6-01.6.2.B the minimum alley width for refuse maneuverability is 20-feet. Any deviation from the Development Standard and/or Figure 3a (or b) will require prior approval from Environmental Services along with a Development Standard Modification Request (DSMR) application and approval.


GENERAL COMMENTS:

Please provide a revised Development Plan Package and referenced Geotechnical Report that addresses the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

Further comments may be generated upon re-submittal of the Development Plan Package. For any questions or to schedule meetings call me at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
Planning & Development Services Department
11/15/2012 RBROWN1 ADA REVIEW Passed
11/20/2012 RONALD BROWN H/C SITE REVIEW Approved
11/21/2012 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Street landscape borders shall be located entirely on site, except that, if approved by the City Engineer or designee, up to five (5) feet of the required ten (10) foot width be placed within the adjacent right-of-way area. Obtain permission for use of ROW

2. All plant material used for required landscaping shall be selected from the Drought Tolerant Plant List in Development Standard 9-06. Chitalpa x pink dawn is not on the list. Choose appropriate tree variety for vehicle use area canopy requirement.

3. An unpaved planting area, which is a minimum of thirty-four (34) square feet in area and four (4) feet in width, must be provided for each canopy tree within vehicle use area LUC 3.7.2.3.A.1.d. Dimension interior landscape buffer adjacent to parking area.

4. Provide the height and location of screening elements on the landscape plan DS 2-07.2.2.3.a & b.

5. The site and landscape plans must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan.

6. Additional comments may apply.
11/26/2012 ANDREW CONNOR NPPO REVIEW Approved
11/27/2012 TERRY STEVENS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Terry Stevens
Lead Planner

PROJECT: DP12-0209
124 S. Cherry Av
Development Package

TRANSMITTAL DATE: 11/27/12

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. DS 2-01.3.3 This project has been assigned case number DP12-0209. Place this case number near the lower right corner of all sheets.

2. DS 2-01.3.9.H.5 Per LUC Sec.3.3.66.D.3 A minimum distance of three (3) feet shall be provided between the back of spur and any wall, screen or other obstruction over six (6) inches in height. Provide the minimum 3' dimension at the back of the backup spur.

3. DS 2-01.3.9.H.5.a Per LUC Sec. 3.3.4.2 for Group Dwelling in the Residential Use Group the minimum number of required vehicle parking spaces is 0.5 space per resident plus 2 spaces for the resident family. Revise parking calculation.

4. DS 2-01.3.9.H.5.d In the bicycle parking calculations for the long term bicycle parking, indicate that the long term bicycle parking spaces will be located with each residential unit, See LUC Sec. 3.3.9.4.B.1.

Per LUC Sec. 3.3.9.3.B.4 Where buildings have more than one public entrance short-term bicycle parking shall be distributed so that at least one (1) short-term bicycle parking space is within fifty (50) feet of each public entrance. Per the location of the sidewalk at the northeast corner of the building, this entrance is considered a public entrance.

Per LUC Sec. 3.3.9.2.B.8 a 5' access aisle is required for the short term bicycle parking spaces. Per detail F on page 3 of 6 the access aisle cannot be located in the handicap parking space. Revise.

On detail F on page 3 of 6 clearly indicate the type of surfacing material for the short term bicycle parking spaces. See LUC Sec. 3.3.9.2.A.4.

5. DS 2-01.3.9.O Per LUC Sec. 3.2.6.5.A Within established areas (which this project is considered), the front street perimeter yard is twenty (20) feet or one and one-half (1 1/2) the height of the proposed wall (H), measured from the street property line, whichever is greater. Provide the wall height measured from the adjacent grade of all elevations in order to determine the correct setback. The building height of 32 feet would require a street perimeter setback of 48' not the indicated 20'. A Design Development Option would be required to be submitted for and approved in order to reduce the required setback. Note the indicated foot print of the building does not meet the minimum 20' setback. Provide a dimension from the wall closest to the street property line.

If a DDO is applied for and approved place the case number near the lower right corner of all sheets. Provide a general note indicating the case number, date of approval, what the DDO is for and any conditions of approval.

An application for the DDO is available on line or can be obtained over the counter at PDSD.

6. DS 2-01.3.9.Q Provide dimensions of the proposed building on the foot print shown on sheet 2 of 6.

7. DS 2-01.3.9.R Clearly indicate that the pedestrian circulation path indicated at the northeast corner of the building is connecting to a public access. Per DS 2-08.3.1 clearly indicate that there is an accessible route through the building connecting to the rest of the pedestrian circulation path.


If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

C:\planning\cdrc\DSD\DP12-0209.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
11/27/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
11/29/2012 KEN BROUILLETTE FIRE REVIEW Approv-Cond Building will be required to have an approved fire sprinkler and fire alarm system installed.

Final Status

Task End Date Reviewer's Name Type of Review Description
11/29/2012 FERNE RODRIGUEZ OUT TO CUSTOMER Completed