Review Date Reviewer's Name Type of Review Description Status Comments
04/11/2013 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/11/2013 RONALD BROWN ZONING HC REVIEW Approved
04/11/2013 LAITH ALSHAMI ENGINEERING REVIEW Approved Laith Alshami, Engineering and Floodplain Review, 04/08/2013,

SUBJECT: CAID Industries
DP12-0206, T15S, R14E, SECTION 08

RECEIVED: Development Package on March 13, 2013

The subject submittal has been reviewed. The Drainage Report and Development Package are recommended for approval pertaining to Engineering and Floodplain.

If you have any questions, I can be reached at 837-4933 or Laith.Alshami@tucsonaz.gov
04/11/2013 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Caid Industries - Site Expansion
Development Package (2nd Review)
DP12-0206

TRANSMITTAL DATE: March 19, 2013

DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

The following comments are based on Development Standard 2-01.0:

1. This comment was not addressed. The west end of the perpendicular vehicle parking spaces, the two angled vehicle parking spaces and the access lane connecting the proposed parking to the existing parking require some type of barrier to prevent vehicles from accessing the unpaved areas. D.S. 2-01.3.9.H Per LUC Section 3.3.6.8.A Barriers, such as post barricades or wheel stop curbing, are required in a vehicular use area to prevent vehicles from extending beyond the property lines, damaging adjacent landscaping, walls, or buildings, overhanging adjacent sidewalk areas or unpaved areas, and/or driving onto unimproved portions of the site. That said provide some type of barrier at the west end of the proposed parking.

2. Once the above comment has been addressed Zoning is willing to provide and over the counter review. Please call or email to schedule this review.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com

Sshield1 on DS1/planning/New Development Package/ DP12-0206

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package.
04/11/2013 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Denied PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

DP12-0206 CAID Industries 4/11/13

() Tentative Plat
(X) Development Plan
(X) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other - Elevations

CROSS REFERENCE: Concurrent Review - see C9-12-16

NEIGHBORHOOD PLAN: Kino Area Plan and the General Plan
GATEWAY/SCENIC ROUTE: NO
COMMENTS DUE BY: 12/10/12

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

(X) Denied. See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(X) Resubmittal Required:
() Tentative Plat
(X) Development Plan
(X) Landscape Plan
() Other

Staff offers the following comments:
1. Provide Detail showing that7-foot wall meets rezoning Condition 9. Keynote 15 (Sheet C2.0 and C2.1) should refer to Wall Detail.
2. Call out Landscaping Rezoning conditions: 8, 12, 13 on Landscape Sheet L1.0.

REVIEWER:JB 837-6966
04/11/2013 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change Include with re-submittal Re-zoning approval documentation. Indicate on the lower right hand corner of the landscape plan, date of approval, and any landscape conditions imposed. Provide written verification that all conditions of re-zoning have been met.

Provide Environmental Resource Report with next submittal for review and approval.
04/12/2013 MICHAEL WYNEKEN ZONING-DECISION LETTER REVIEW Denied This review has been completed and resubmittal is required.

Please provide the following items.

1) A disk containing all plans and all documents submitted.
2) Two (2) sets of rolled plans.
3) All items requested by the reviewers.
4) All approved items.
04/12/2013 GARY WITTWER DOT LANDSCAPE REVIEW Denied I have reviewed the above noted Development Plan and have the following comments concerning the trees to be planted in the ROW:

1. The City has an existing planting and irrigation system in this area.
2. How will these trees be irrigated long term.
3. Who will maintain them long term.

Final Status

Task End Date Reviewer's Name Type of Review Description
04/16/2013 CPIERCE1 OUT TO CUSTOMER Completed