Permit Number: DP12-0202
Parcel: 136192140

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP12-0202
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/09/2013 CPIERCE1 START PLANS SUBMITTED Completed
01/14/2013 DAVID RIVERA ZONING REVIEW Approved
01/24/2013 PAUL MACHADO ENGINEERING REVIEW Approved
01/28/2013 TIM ROWE PIMA COUNTY WASTEWATER Denied MEMORANDUM
PUBLIC WORKS - DEVELOPMENT SERVICES





DATE: January 28, 2013

TO: Patricia Gehlen, Subdivision Coordinator

FROM: Robert E. Flynt, Public Works Manager
Development Review Division (Environmental Quality)

SUBJECT: Dollar General - Pantano & Escalante
DP12-0202


On behalf of the Department of Environmental Quality, the Development Plan has been reviewed for conformance with Pima County Department of Environmental Quality requirements for on-site wastewater disposal and air quality. Please note the following comments:

1. In accordance with Pima County Code (P.C.C.) 7.21.037, construction of on-site sewage disposal systems is prohibited where connection to a public sewer system is determined by PDEQ to be practical. Connection to the public sewer system shall be made for residential and commercial properties when there is a public sewer available to serve the property within 200 feet of the nearest property line, as measured along the usual or most feasible route of access. Please revise the submittal to provide / indicate connection to public sewer to the north (G-2001-125), as originally proposed, OR provide written evidence of approval from PDEQ for on-site sewage disposal pursuant to P.C.C. 7.2.1.037.E

2. If on-site sewage disposal is allowed please revise Key Note 48 to reflect the tank size required in accordance R18-9-A314.4.b.

3. If on-site sewage disposal is allowed please add a General Note as follows: The property owner(s) assume full responsibility if the on-site sewage disposal system, as designed, cannot be constructed. Furthermore, Pima County and its representatives shall be held harmless in the event the property cannot be developed as planned.

4. If on-site sewage disposal is allowed please add a Restrictive Note as follows: The proposed development will be served by an on-site sewage disposal system. Prior to construction a Notice of Intent to Discharge shall be submitted to PDEQ in order to receive a Construction Authorization.













5. While it has been acknowledged that a conceptual wastewater disposal area has been shown, if on-site sewage disposal is allowed and with your next submittal, please provide the results of soil analysis and/or percolation testing, at an adequate depth, in both the primary and reserve disposal areas for the proposed system, along with trench design calculations, to ensure the areas shown are appropriately sized based on the proposed loading and the assigned Soil Absorption Rate (SAR). Additionally, please indicate the location of the aforementioned 100% reserve disposal area and soil testing sites on the plan(s).

If you wish to discuss the above comments, please contact me at 740-6502.

The Department's Air Quality Control District requires that air quality activity permits be secured by the developer or prime contractor before constructing, operating or engaging in an activity which may cause or contribute to air pollution.
01/30/2013 ANDREW CONNOR LANDSCAPE REVIEW Approved
02/04/2013 KBROUIL1 COT NON-DSD FIRE Approved
02/05/2013 RONALD BROWN ZONING HC REVIEW Approved
02/06/2013 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: DP12-0202 DOLLAR GENERAL PANTANO/ESCALANTE/REVISED DEVELOPMENT PLAN
DATE: February 6, 2013



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.


Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar or bond paper of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.
02/06/2013 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied Approval by PC WWM is still required.

Final Status

Task End Date Reviewer's Name Type of Review Description
02/07/2013 FERNE RODRIGUEZ OUT TO CUSTOMER Completed