Permit Number: DP12-0188
Parcel: 136075680

Address:
9484 E 22ND ST

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP12-0188
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/05/2012 CPIERCE1 START PLANS SUBMITTED Completed
11/05/2012 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved The proposed rezoning action at Harrison and 22nd lies outside any ADOT facilities and Regional Traffic Engineering supports its approval.

________________________________

Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments.
.
11/05/2012 RONALD BROWN ADA REVIEW Passed
11/05/2012 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Passed
11/05/2012 PGEHLEN1 OTHER AGENCIES PAG - PIMA ASSN OF GOVTS Approved No objections or adverse comments. See attached (Attachments are in SIRE).





____________________________

Eric W. Kramer, Ph.D., AICP

Senior Land-Use Modeler

PAG_logotype

177 N. Church Ave, Suite 405

Tucson, AZ 85701

(520) 792-1093 x506 (tel)

(520) 620-6981 (fax)

www.pagnet.org

<mailto:ekramer@pagnet.org> ekramer@pagnet.org

See comments in SIRE
11/05/2012 PGEHLEN1 COT NON-DSD ENVIRONMENTAL SERVICES Approved The Enclosure does not meet standards. The inside width is not wide enough for commercial waste containers and the bollard placement is incorrect.
Please refer to this manual for stds.


http://cms3.tucsonaz.gov/files/dsd/Codes-Ordinances/ds%206-01.pdf





Jeff Drumm, P.E.
Environmental Manager
City of Tucson Environmental Services
520-837-3713
11/05/2012 PGEHLEN1 COT NON-DSD ENVIRONMENTAL SERVICES Approved Solid Waste and Recycle approved.



Jeff Drumm, P.E.
Environmental Manager
City of Tucson Environmental Services
520-837-3713
11/06/2012 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702

WR#256232 November 5, 2012

Cypress Civil Development
Attn: K. Hall
2102 N. Country Club Rd.
Tucson, Arizona 85716

Dear K. Hall :

SUBJECT: Harrison & 22nd Street
DP12-0188

Tucson Electric Power Company has reviewed and approved the development plan submitted October 25, 2012 It appears that there are conflicts with the existing facilities within the boundaries of this proposed development.

" Existing facilities are across 22nd St. to the North

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans.

If easements are required, they will be secured by separate instrument. Your final plans should be sent to:
Tucson Electric Power Company
Attn: Mr. Richard Harrington
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8726

Should you have any technical questions, please call the area Designer Charles Leon at (520) 917-8707.

Sincerely,


Joann Hayes
Administrative 1
Design/Build

Enclosures
cc: DSD_CDRC@tucsonaz.gov, City of Tucson (email)
C. Leon, Tucson Electric Power
11/09/2012 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: DP12-0188
9484 E. 22nd St.
Development Package

TRANSMITTAL: 11/19/2012

DUE DATE: 11/23/2012

COMMENTS:

1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is 10/22/2013.

2. DS 2-01.3.3 Relevant case numbers (development package document DP12-0188, rezoning C9-11-06) shall be provided adjacent to the title block on each sheet.

3. DS 2-01.3.7.A.3 The existing zoning is RX-1and SR. The proposed zoning is C-1. This plan has been prepared in conjunction with a rezoning application, add the following note next to the existing zoning note: "Proposed zoning is ____." List the applicable rezoning file number and conditions of approval. Also place the C9-__-__ and the plan/plat file numbers in the lower right corner of each sheet.

Provide a written response clearly indicating how each of the rezoning conditions have been met.

4. DS 2-01.3.7.A.6.c Provide a note indicating that this project has been designed to meet the criteria of Sec. 2.8.3 Major Streets and Routes (MS&R) Setback Zone.

5. DS 2-01.3.8.C Provide the width of the right of way for Harrison Rd.

6. DS 2-01.3.7.F Trails Notes. List the following notes as appropriate.

1. If a trail or path is proposed, provide a note, as appropriate, indicating that a trail
or path will be constructed for public or private use, the general location of the trail
or path, and whom it will be constructed and maintained by. If it is intended to
connect to an offsite feature, such as an exiting trail, wash, sidewalk, road,
commercial or residential development, etc., so indicate. If the trail or path is to be
dedicated, indicate the method of dedication.

Per rezoning condition #17 the developer shall dedicate a 32' wide public easement for a trail and landscape. Provide the location of the easement and recording information on this plan.

2. If a new trail or path will be constructed, add the following note, as appropriate:
"All new onsite and offsite trails or paths constructed in conjunction with this
project will be constructed in accordance with approved plans. Construction plans
will be subject to the review and approval of the City's Parks and Recreation
Department, and, if requested, Pima County Natural Resources, Parks and
Recreation."

3. The Eastern Pima County Trails System Master Plan does not show any trails on
or adjacent to the development site.

Per rezoning condition #17a the asphalt walking path shall be a minimum of 12' in width. The plan indicates 11.4'. Revise.

Per rezoning condition #17a the walking path shall extend from the sidewalk Per rezoning condition #17a at Harrison Rd to the 22nd St. right of way. The plan does not show the path connecting to the sidewalk at Harrison Rd.

Per rezoning condition #16 a 6' wall is required, approximately 32' from the south and west property lines. Clearly indicate the location of this required wall on sheet 2 of 8.

7. DS 2-01.3.9.F All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. If the property is being rezoned, use those boundaries and classifications.

8. DS 2-01.3.9.H.2 Show future and existing sight visibility triangles. On a designated MS&R street, the sight visibility triangles are based on the MS&R cross-section.

9. DS 2-01.3.9.H.5.a Provide in the parking calculations the total number of parking spaces provided for the entire site.

10. DS 2-01.3.9.H.5.d Review LUC Sec. 3.3.9.3.B.1 and .4 for location of short term bicycle parking spaces. Clearly indicate the location on sheet 2 of 8.

Each tenant must provide short term and long term bicycle parking spaces. See LUC Sec. 3.3.8 for the number of required spaces. 2 short term and 2 long term for each tenant. Revise calculations.

Provide a detail of the long term bicycle parking spaces clearly indicating compliance with LUC Sec. 3.3.9.4.B.2 and .3. Indicate location on the footprint of the building and cross reference to the detail.

11. DS 2-01.3.9.J If street dedication is not required or proposed and the project site is adjacent to a Major Street or Route, draw the Major Street right-of-way lines for those streets. (Add the MS&R future sidewalk, right-of -way lines, sight visibility triangles, etc.) Provide for the right of way along Harrison Rd.

12. DS 2-01.3.9.O Provide the required building setback from the back of future curb along Harrison Rd.

13. DS 2-01.3.9.Q Provide dimensions on the footprint of the proposed building. Clearly indicate the 3 separate tenant spaces with dimensions.

Provide dimensions of the proposed patio areas and label as outdoor dining areas. Clearly indicate if these areas are covered. Note: The required pedestrian circulation path connecting to both right of ways and the building cannot pass through the outdoor dining areas.

14. DS 2-01.3.9.U Provide a written response on how all of the conditions of rezoning have been complied with.

List all of the rezoning conditions of approval on the plan.

15. DS 2-01.3.9.W If applicable, indicate the locations and types of proposed signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met.


If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

TLS C:\planning\cdrc\developmentplan\DP12-0188dp.doc
11/13/2012 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
11/15/2012 RONALD BROWN ZONING HC REVIEW Denied SHEET 2 OF 8
1. Provide dimension on Van Accessible parking space of 11'-0" not 8'-0".
2. Provide grade slopes for the accessible parking areas as per ICC A117.1, Section 502.5.
3. Provide accessible route slopes as per ICC A 117.1, Section 403.3, 5% max running and 2% max cross.
SHEET 3 OF 8
4. Show spot grades and percentages for the following:
a. Accessible parking areas max 2% in all directions
b. At all accessible routes as per section 403.3
c. At both accessible connections to both street rights of way
END OF REVIEW
11/19/2012 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Denied AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: DP12-0188 22ND & HARRISON/DEVELOPMENT PLAN
DATE: November 16, 2012



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1. Delete all street directions.
2. Is this all of Block A of Harrison Terrace 56/66? If so, delete "a portion of" on all title blocks.
11/19/2012 PGEHLEN1 COT NON-DSD TUCSON POLICE DEPARTMENT Approved I have no issues with this request.

CSO Becky Noel #37968
Tucson Police Dept
837-7428
11/20/2012 LOREN MAKUS ENGINEERING REVIEW Denied Show the dimensions for the Harrison Road right-of-way.
Provide the SVTs for the intersection of Harrison Road and 22nd Street. Also show the future SVTs for 22nd and Harrison Roads.
Provide radius dimensions for driveways. The radii must be 25 feet, per the Transportation Access Management Guidelines.
11/21/2012 JOE LINVILLE NPPO REVIEW Approv-Cond See landscape comments.
11/21/2012 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Add any related case numbers to the site, landscape and native plant preservation plans. DS 2-07.2.1.B. The previous WASH approval is vital.

2) Dimension the length and width of landscape borders on the landscape plan per DS 2-07.2.2.A.2.f. Minimum width requirements should be adhered to except as allowed per #3 below.

3) Landscape borders proposed in right-of-way or MS&R areas must be approved by the City Engineer or designee and comply with the City Engineer's requirements on construction, irrigation, location, and plant type. Provide verification, in writing, of any approvals obtained. Contact Gary Wittwer, DOT Landscape Architect for specific requirements.

4) Revise the landscape plan to include the correct calculation for of the required number of canopy trees for the vehicular use area. LUC 3.7.2.3. The correct ratio 4:1.

5) Show and label all proposed screen walls on the development and landscape plans. DS 2-07.2.2. Provide details as necessary.

6) Revise the landscape and native plant preservation plans to show the limits of grading. DS 2-15.3.4.A

7) Revise the landscape plans to include the required WASH mitigation per the Harrison Terrace subdivision. The requirements are documented on the landscape plans and possibly also on the plans associated with the previously approved World Savings Bank. DS 9-06.2.5

8) Revise the plans as necessary to comply with any conditions of rezoning.
11/23/2012 TIM ROWE PIMA COUNTY WASTEWATER Denied PIMA COUNTY
REGIONAL WASTEWATER RECLAMATION DEPARTMENT
201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 740-6500
DIRECTOR FAX: (520) 620-0135


November 21, 2012

To: KEVIN HALL, P.E.
CYPRESS CIVIL DEVELOPMENT LLC

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department


____________________________________________
From: Tom Porter, Sr. CEA (520-740-6719), Pima County Regional Wastewater Reclamation Department

Subject: SWC 22ND STREET AND HARISON DEVELOPMENT
Development Plan - 1st submittal
DP12-0188

The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer collection lines for the above-referenced project. The following comments are offered for your use:
1. Obtain a letter from the PCRWRD's Development Liaison Unit, written within the past year, stating that treatment and conveyance system capacity for the project is available in the downstream public sewerage system and provide a copy of that letter to this office. The required form to request such a letter may be found at:

http://www.pima.gov/wwm/developer.htm#permits

The development plan for this project cannot be approved until a copy of this letter has been received by this office.

2. Include the following General and Permitting Notes:

THE ON-SITE SANITARY SEWERS WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS, AND IN ACCORDANCE WITH AN APPROVED OPERATION AND MAINTENANCE PLAN, IF REQUIRED. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT.

A PROJECT CONSTRUCTION PERMIT MUST BE SECURED FROM PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT BEFORE BEGINNING ANY WORK ON THIS PROJECT.

3. Sheet 2: Revise the proposed connection to the existing public sewer. Show a direction connection to the public line approximately five feet south of MH # 4164-07 at a right angle to the line. The proposed private 4" BCS should also cross the property line at a right angle.

This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the second(2nd) submittal. A check for the review fee of this submittal in the amount of $100.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.


Ref. A. Development Plan Checklist Requirements - Chapter 18.71 of the Pima County Code - Section J
http://www.pimaxpress.com/SubDivision/Documents/2006/DP_Requirements2Aug04.pdf

Ref. C - Arizona Administrative Code, Title 18, Chapters 5 & 9 (R18-5-205)
http://www.azsos.gov/public_services/Title_18/18-05.htm
and (R-18-9-E301)
http://www.azsos.gov/public_services/Title_18/18-09.htm

Ref. D - PCRWRD Procedures, Preliminary Sewer Layout Requirements, 1984 (revised April 1988)
http://www.pima.gov/wwm/eng/stddet/pdf/procedures.pdf

Ref. E - PCRWRD Design Standards for Public Sewerage Facilities, 1983 (revised April 1988)
http://www.pima.gov/wwm/eng/stddet/pdf/design_standards.pdf

Ref. F - City of Tucson/Pima County Standard Details
http://www.pima.gov/wwm/eng/stddet/pdf/all_det.pdf

Ref. G - Pima County Code of Ordinances, Title 13 - Public Services, Division II - Sewers
http://library.municode.com/index.aspx?clientID=16119&stateID=3&statename=Arizona

Ref. H - City of Tucson/Pima County Standard Specifications for Public Improvements, 2003 Edition
http://dot.pima.gov/transeng/stdspecsdet/standardspecs2003.pdf

Ref. I - PCRWRD Engineering Directives
http://www.pima.gov/wwm/eng/directives/
11/23/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Revise the site drawing to include the location and size of the backflow preventer for the water service. Reference: City of Tucson Development Standard No. 2-01.0.0, Section 3.8 D and Section 103.2.3, UPC 2006.
2. The rim elevation of the next upstream sanitary manhole (2772.31') is less than 12" below the first floor elevation (2772.50'). Provide a backwater valve per Section 710.1, UPC 2006, as amended by the City of Tucson.
11/26/2012 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied This review has been completed. Resubmittal is required.
11/26/2012 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
11/26/2012 CSCHULT1 COT NON-DSD FIRE Denied On site plan Pg.2 Please put the following:
Please indicate existing fire hydrant location(s), with dimensions to buildings and/or property lines. Refer to City of Tucson amendments to the 2006 International Fire Code (section 508) for spacing and location requirements
11/26/2012 ED ABRIGO PIMA COUNTY ASSESSOR Passed
11/26/2012 PGEHLEN1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Passed
11/26/2012 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
11/29/2012 CPIERCE1 OUT TO CUSTOMER Completed
11/29/2012 CPIERCE1 REJECT SHELF Completed