Permit Number: DP12-0186
Parcel: 11504520A

Review Status: Completed

Review Details: DEV PKG - REVISION

Permit Number - DP12-0186
Review Name: DEV PKG - REVISION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/02/2013 AROMERO4 START PLANS SUBMITTED Completed
08/05/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
08/05/2013 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: The HUB at Tucson
Development Package (Revision 1)
DP12-0186

TRANSMITTAL DATE: August 5, 2013

DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. D.S. 2-01.3.9.H.2 Keynote 29 calls out "RAILING PER ARCHITECTUREAL PLANS". The proposed railing encroaches in to the sight visibility triangle (SVT) shown near the southeast corner of the building. Remove the railing from the SVT or provide a detail of this railing that demonstrates how the requirements of D.S. 3-01.5.1 are met.

2. D.S. 2-01.3.9.L The proposed water easement will need to be recorded prior to issuing the Certificate of Occupancy for the building.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com

Sshield1 on DS1/planning/New Development Package/ DP12-0186

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package.
08/08/2013 MARTIN BROWN COT NON-DSD FIRE Approved
08/09/2013 LOREN MAKUS ENGINEERING REVIEW Denied Show how the railing along the southeast corner meets the SVT requirements. If parking is allowed along the perimeter streets, the SVTs may be aligned with the edge of travel lane. Otherwise show how the railing doesn't obstruct visibility.
08/12/2013 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702

WR#256127 August 12, 2013

Grenier Engineering Inc
Attn: John Grenier
5524 E 4th St
Tucson, Arizona 85711


Dear Mr. Grenier:


SUBJECT: The Hub of Tucson
DP12-0186

Tucson Electric Power Company has reviewed and approved the development plan submitted August 6, 2013. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans.

If easements are required, they will be secured by separate instrument. Your final plans should be sent to:
Tucson Electric Power Company
Attn: Mr. Richard Harrington
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8726

Should you have any technical questions, please call the area Designer Mike Kaiser at (520) 918-8244.
Sincerely,


Elizabeth Miranda
Office Support Specialist
Design/Build
Enclosures
cc: DSD_CDRC@tucsonaz.gov, City of Tucson (email)
M. Kaiser, Tucson Electric Power
08/14/2013 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
08/14/2013 TIM ROWE PIMA COUNTY WASTEWATER Approved See PCRWRD form in SIRE
08/16/2013 JOE LINVILLE LANDSCAPE REVIEW Approved
08/19/2013 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Approved
08/20/2013 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied Review has been completed and resubmittal is required.

Please resubmit the following items:

1) Two rolled sets of the plans
2) All items requested by review staff
3) All items needed for the review.
4) A disk containing all items submitted.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/16/2013 CPIERCE1 REJECT SHELF Completed