Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP12-0186
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/27/2013 | PGEHLEN1 | START | PLANS SUBMITTED | Completed | |
| 02/28/2013 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 03/01/2013 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approved | |
| 03/01/2013 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 03/01/2013 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Planning and Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: The HUB at Tucson Development Package (3rd Review) DP12-0186 TRANSMITTAL DATE: March 1, 2013 DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Zoning Review Section conditionally approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. 2. D.S. 2-01.3.8.B Provide the recordation information for all existing easement shown to be abandoned on the plan. A hold will be put on the building certificate of occupancy, T13CM00547, until the recordation information is provided. 3. There appears to be architectural features proposed within the right-of-way (ROW). These features will need to be approved by the Department of Transportation and any required permits, licenses or easements will need to be obtained. A hold will be put on the building certificate of occupancy, T13CM00547, until the documentation approving the architectural features in the ROW is provided. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com Sshield1 on DS1/planning/New Development Package/ DP12-0186 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/06/2013 | CPIERCE1 | APPROVAL SHELF | Completed |
| 06/06/2013 | CPIERCE1 | OUT TO CUSTOMER | Completed |