Permit Number: DP12-0183
Parcel: 134234110

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP12-0183
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/19/2012 CAGUILA1 START PLANS SUBMITTED Completed
10/22/2012 RONALD BROWN ADA REVIEW Passed
10/23/2012 RONALD BROWN ZONING HC REVIEW Denied 1. Provide an accessible route to the dumpster as required by development standards. Reference Zoning comments.
END OF REVIEW
10/25/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
10/29/2012 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Fences or walls constructed in a single continuous line shall extend into a street landscape border no more than the actual width of the fence or wall. Where a fence or wall incorporates offsets or similar design features, a screen may extend a maximum of three (3) feet into the street landscape border.

Hedges and other vegetative screens shall not extend more than three (3) feet into the street landscape border per LUC 3.7.3.2.C.2.

Revise the plans to address the screen wall location requirements.

2) The vehicular use areas must be provided with post barricades or wheel stop curbing designed to prevent parked vehicles from extending beyond the property lines; damaging adjacent landscaping, walls, or buildings and to prevent vehicles from driving onto unimproved portions of the site per LUC 3.3.6.8.A. Revise the plans as necessary to indicate the type of existing curb to remain where indicated surrounding the pads.

3) Revise the landscape plan to include all of the areas covered by the site and grading plans. DS 2-07.2.1

Street landscape borders (LUC 3.7.2.4) and screening elements (LUC 3.7.3.5.A) are required, as well as dust control treatment per LUC 3.7.2.7

4) Landscape elements and other items proposed in right-of-way or MS&R areas must be approved by the City Engineer or designee and comply with the City Engineer's requirements on construction, irrigation, location, and plant type. Provide verification, in writing, of any approvals obtained. Contact Gary Wittwer, DOT Landscape Architect for specific requirements. (520) 837-6618.

5) Revise the landscape plans to clearly show the public sidewalks. DS 2-07.2.1

6) Revise the water harvesting plan calculations for the plant canopy area . See DS 10-03 and the spreadsheet at http://cms3.tucsonaz.gov/devnews/news/commercial-water-harvesting.
Standard mature plant sizes can be obtained at http://www.azwater.gov/AzDWR/WaterManagement/AMAs/documents/2007_Plant_List_apha_botanical.pdf
10/30/2012 TERRY STEVENS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Terry Stevens
Lead Planner

PROJECT: DP12-0183
6310 E. Broadway Blvd.
Development Package

TRANSMITTAL DATE: 10/29/12

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. DS 2-01.3.3 This project has been assigned case number DP12-0183. Place this number near the lower right corner of all sheets.

A lot split has been submitted for this project and has been assigned case number S12-048. Place this number near the lower right corner of all sheets.

This plan cannot be approved until the lot split has been approved and recording information has been completed. The lot split can be completed over the counter by setting an appointment with me.

2. DS 2-01.3.7.A.2 The gross area indicated in general note number 1 should indicate the gross area of the site for the CVS Pharmacy only.

3. DS 2-01.3.7.H.5 Clearly indicate the height clearance of the drive though canopy. Per LUC Sec.3.3.6.5.B The minimum height clearance along access lanes and PAALS is fifteen (15) feet. The drive thru bypass lane is considered an access lane.

4. DS 2-01.3.9.R The flush sidewalk adjacent to the northern most handicap parking space along the west side of the building must be physically separated from the parking space. See LUC Sec. 3.3.6.8.A. Provide curbing in this area

5. The above comments are minor in nature and can be approved over the counter by setting an appointment with me.

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

C:\planning\cdrc\DSD\DP12-0183.doc
10/30/2012 CHRIS POIRIER PIMA COUNTY ADDRESSING Approv-Cond AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: DP12-0183 CVS PHARMACY/DEVELOPMENT PLAN
DATE: October 30, 2012



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

Note: On the Final Development Plan add the section, township and range to the title blocks.

1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar or bond paper of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.
10/31/2012 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
11/01/2012 PAUL MACHADO ENGINEERING REVIEW Denied To: Rick Engineering Company DATE: November 1, 2012
6150 N. 16th Street FROM: Paul Machado
Phoenix, Az., 85016 Engineering Division

Subject: CVS pharmacy, 6310 E. Broadway Blvd.
Development Package, DP12-0183 (First Review)
T14S, R15E, Section 18

RESUBMITTAL REQUIRED: Development Package and Drainage Report

The Development Package (DP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Development Package:

1. Please include a response letter to the comments along with the corrected copies of the DP.
2. General Notes. The following general notes are required. Additional notes specific to each plan are required where applicable. D.S. 2-01.3.7.
B. Drainage Notes. List the following note as appropriate.
3. List the following note on all development package documents
a. "Drainage will remain in its natural state and will not be altered, disturbed, or obstructed other than as shown on this (site or development) plan."
F. Trails Notes. List the following notes as appropriate.
3. The Eastern Pima County Trails System Master Plan does not show any trails on or adjacent to the development site.
E. Indicate the ground elevation on the site based on City of Tucson Datum (indicate City of Tucson field book number and page).
F. Existing storm drainage facilities on and adjacent to the site will be shown.
3. Information on Proposed Development. The following information on the proposed project shall be shown on the drawing or added as notes. D.S. 2-01.3.9.
6. If the project is phased, the phase under consideration shall be designed so those later phases are assured legal access. If such access is provided through the phase under consideration, public streets are required, or access easements must be delineated and dedicated for such use. If private easements are utilized, protective covenants establishing the right of access and incorporation of future phases into this project are required.
N. In conjunction with a drainage report or statement, as applicable, prepared in accordance with the City Engineer's instructions and procedures, the following information will be indicated on the development package documents. For additional information regarding drainage standards, see the City of Tucson Standards Manual for Drainage Design and Floodplain Management.
4. Indicate all proposed ground elevations at different points on each lot to provide reference to future grading and site drainage including future pad elevations.
7. Draw locations and indicate types of off-site runoff acceptance points and/or onsite
runoff discharge points.
O. All applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown.
22. Include a compact disk (CD) containing the latest/revised submittal of the dev. plan, reports and documents associated with this project with the latest submittal.
23. It is suggested that after my comments have been addressed, that you make an appointment with me to discuss any of my comments that you may have questions on. If I missed any information or made a mistake we can go over those items at the meeting. Do not hesitate to call if there are any questions or disagreements on my comments as you address them.

Drainage Report:
1. Please include a response letter to the comments along with the corrected copies of the DR.
2. Per the DR, "each type of drainage structure" is a new curb opening. However, per the SMDDFM the "10 year" event shall be conveyed through sidewalk scuppers. If TDOT requires sidewalk scuppers or any other drainage passes over any sidewalks, then the DR will have to be revised to include those calculations.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson - Planning and Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/6310 E. Broadway Blvd DEVPKG
11/01/2012 MARTIN BROWN FIRE REVIEW Approved
11/05/2012 PGEHLEN1 PIMA COUNTY WASTEWATER Approved 201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 740-6500
DIRECTOR FAX: (520) 620-0135


November 2, 2012


To: DAN MANN
RICK ENGINEERING CO.

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department


____________________________________________
From: Tom Porter, Sr. CEA (520-740-6719), Pima County Regional Wastewater Reclamation Department

Subject: CVS Pharmacy
Development Plan - 1st submittal
DP12-0183

The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer collection lines for the above-referenced project. The following comments are offered for your use:
The Pima County Regional Wastewater Reclamation Department hereby approves the above referenced submittal of the development plan.
11/05/2012 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied Review completed. Revisions required.

Final Status

Task End Date Reviewer's Name Type of Review Description
11/05/2012 PGEHLEN1 APPROVAL SHELF Completed
11/05/2012 PGEHLEN1 OUT TO CUSTOMER Completed
11/05/2012 PGEHLEN1 REJECT SHELF Completed