Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - REVISION
Permit Number - DP12-0181
Review Name: DEV PKG - REVISION
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/08/2016 | AROMERO4 | START | PLANS SUBMITTED | Completed | |
| 03/22/2016 | MARTIN BROWN | COT NON-DSD | FIRE | Approved | |
| 04/01/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 04/04/2016 | SSHIELD1 | ZONING HC | REVIEW | Approved | |
| 04/04/2016 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 04/05/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. The rim elevation of the next upstream sanitary manhole (MH# 9752-01, 2309.81') is higher than the first floor elevation of the existing detail building (FFE 2308.0').Backwater valve protection will be required for any future plumbing modifications in this building per Section 710.1, UPC 2006, as amended by the City of Tucson. 2. It is not clear how the proposed car wash building (FFE 2305.5') will be connected to the sewer system. If the finished floor elevation is less than 12" above the rim elevation of the next upstream manhole, provide a backwater valve per Section 710.1, UPC 2006, as amended by the City of Tucson. |
| 04/06/2016 | JOE LINVILLE | LANDSCAPE | REVIEW | Reqs Change | 1) AM 2-06.4.9.G If the project is to be phased, provide calculations, setbacks, etc., to indicate that each phase complies with all requirements as a separate entity. Show phase lines on the drawing. The Landscape Plans and the Site/Phasing Plan are required to reflect the same boundaries to clarify compliance with requirements. 2) UDC 7.6.4.B.1.a.(3) An unpaved planting area, which must be a minimum of 34 square feet in area and four feet in width, must be provided for each canopy tree. |
| 04/12/2016 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Four rolled sets of the plans 2) All items requested by review staff 3) All items needed to approve these plans |
| 04/29/2016 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approv-Cond | See letter and map documents in PRO/SIRE. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/06/2016 | ARUIZ1 | OUT TO CUSTOMER | Completed |