Permit Number: DP12-0181
Parcel: 10408095C

Address:
700 W WETMORE RD

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP12-0181
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/05/2013 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/10/2013 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Precision Toyota of Tucson
Development Package (2nd Review)
DP12-0118

TRANSMITTAL DATE: April 11, 2013

DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

This plan is reviewed for full code compliance for the entire site for all phased due to a building expansion of greater than 25%.

The following comments are based on Development Standard 2-01.0:

1. Letters from all agencies that have rights to the easements to be abandoned stating that they will be willing to abandon the existing easements once the required work is completed must be provided to PDSD. Once provided Zoning will conditionally approve this development package. D.S. 2-01.3.8.B All easements shown to be abandoned on this development package will need to be abandoned prior to approval of the development package.

2. Zoning acknowledges that a copy of a completed "CONVENAT REGARDING DEVELOPMENT AND USE OF REAL PROPERTY" was submitted with this plan. However no recordation information was provided. D.S. 2-01.3.9.A As the proposed site covers three (3) parcels a lot combination will be required prior to approval of the development package. Provide a copy of the approved Pima County Combination with your next submittal.

3. This comment has not been addressed correctly. Per LUC Section 6.3.10.11 the proposed use of this site is Vehicle Rental and Sales not General Merchandise Sales. That said the following comment still applies. D.S. 2-01.3.9.H.5.c The loading space calculation is not correct. Per LUC Section 3.4.5 Retail Trade Use Group no loading spaces are required.

4. This comment has not been full addressed. Per LUC Section 3.3.9.2.B.6 the minimum distance between racks is 4'-0", not center to center, see LUC Section 3.3.9.5.B Examples of Bicycle Parking Layouts for clarification. Per D.S. 2-01.3.9.H.5.d Sheet 17 Detail 9 demonstrate on the detail how the requirements of LUC Section 3.3.9.2.B.6, .7 & .8 are met.

5. It does not appear that the proposed crosswalk provides an accessible route and the striped crosswalk does not align with the accessible ramp shown on the plan. D.S. 2-01.3.9.R Phase I Show the required pedestrian circulation/accessible route required between all buildings on site, i.e. between building E1 and proposed Service #1.

6. Once the above comments are addressed Zoning is willing to provide an over-the-counter review. Please call or email to schedule this review.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

Sshield1 on DS1/planning/New Development Package/ DP12-0181

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package.
04/22/2013 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all Engineering comments and concerns are addressed prior Landscape approval.
04/24/2013 RONALD BROWN ZONING HC REVIEW Denied RESUBMITTAL COMMENST IN ALL CAPS
SHEET 2 of 17
1. Provide an accessible route to the entrance of the new car display building.
AN ACCESSIBLE ROUTE HAS NOT BEEN PROVIDED TO THE IDENTIFIED FRONT ENTRANCE OF THE NEW CAR DISPLAY BUILDING.
a. Insure that the two accessible parking spaces are adjoined to the accessible route.
THE ACCESSIBLE PARKING AISLE IS NOT CONNECTED OR ADJOINED TO THE ACCESSIBLE ROUTE THAT HAS NOT BEEN PROVIDED.
SHEET 17 of 17
2. At detail 5, detectable warning strips are not required at this situation.
NON RESPONSIDE
ADDITIONAL COMMENTS:
3. Having the front entrance to the new car display building
opening with in the PAAL makes it difficult to comply with landings requirements (2006 IBC, Sections 1008.1.4 and 1008.1.5) and accessible clearances as per ICC A117.1, Section 404.2.3.1 without reducing the required width of the PAAL. Please reconcile.
END OF REVIEW
04/25/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
04/29/2013 LOREN MAKUS ENGINEERING REVIEW Approved
04/30/2013 ZELIN CANCHOLA COT NON-DSD TRAFFIC Denied From TDOT Traffic Engineering
Zelin Canchola

RE DP12-0181 Toyota

Date: April 30,2013

Driveway entry Width City of Tucson Code Chapter 25 Max driveway width in a business district shall be maximum 35 feet., Max at the property line is 30 feet with a 25 foot curb return radius.
05/07/2013 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied This review has been completed and a resubmittal is required. Please resubmit the following:

1) Four rolled sets of the plans,
2) All items requested by review staff
3) All items needed to approve the plans.
05/07/2013 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied WR#261808 May 7, 2013
Revised Comments



M3 Engineering
2051 W Sunset Rd. 101
Tucson, Arizona 85704

Dear M3 Engineering :

SUBJECT: Precision Toyota of Tucson
DP12-0181

Tucson Electric Power Company (TEP) has reviewed the development plan submitted April 5, 2013. TEP is unable to approve the plan at this time. There are existing electrical facilities within the boundaries of the project. In order for TEP to approve the plan the facilities must be depicted correctly on the plan.

TEP has underground and overhead facilities located on this development. Not all TEP facilities have been shown correctly. Transformer AUT-47 does not match the depiction on the development plans (sheet 2 of 17). The plans do not indicate where the existing underground feeds are located. Please see highlighted portion of TEP facilities map.

All costs associated with the relocation of the facilities in conflict will be billable to the customer.

Please resubmit two revised bluelines to the City of Tucson for TEP's review. Should you have any technical questions, please call the area Designer Susie McCann at (520) 917-8741.
Sincerely,


Elizabeth Miranda
Office Support Specialist
Design/Build


cc: City of Tucson (email)
S. McCann, Tucson Electric Power

Final Status

Task End Date Reviewer's Name Type of Review Description
07/30/2013 AROMERO4 OUT TO CUSTOMER Completed
07/30/2013 CPIERCE1 REJECT SHELF Completed