Permit Review Detail
Review Status: Completed
Review Details: RESUB - SITE and/or GRADING
Permit Number - DP12-0146
Review Name: RESUB - SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/20/2012 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Street landscape borders shall be a minimum of ten (10) feet wide as measured from the street property line. On streets designated as Major Streets and Routes (MS&R), the street landscape border is measured from the MS&R right-of-way line as determined by Sec. 2.8.3.4. 2. Required street landscape borders shall be located entirely on site. Only if design restraints dictate, up to five (5) feet of the required ten (10) foot width be placed within the adjacent right-of-way. Additional landscaping may be placed within the adjacent right-of-way area or within the Major Streets and Routes (MS&R) right-of-way area only if approved by the City Engineer or designee. Revise plan as necessary to locate required landscaping on site or obtain permission for use of ROW. 3. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan. 4. Additional comments may apply. |
| 11/26/2012 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 12/03/2012 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approv-Cond | Laith Alshami, Engineering and Floodplain Review, 12/03/2012, SUBJECT: CenturyLink Data Center addition DP12-0146, T14S, R13E, SECTION 01 RECEIVED: Development Package on November 13, 2012 The subject submittal has been reviewed and it can not be approved at this time. The Drainage Statement is acceptable. The Development Package is recommended for conditional approval subject to correcting the following information: Site Plan: 1. The sight visibility triangles (SVT's) appear to be incorrect. The dimensions for a local street to a local street are 180' for the near side and 110' for the far side. The dimensions for a driveway to a local street are 185' for near side and 110 for far side. Revise the dimensions and correct the drawing if needed (D.S. 20-1.3.9.H.2). RESUBMITTAL REQUIRED: Revised Development Plan Package |
| 12/06/2012 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Approved | |
| 12/06/2012 | RONALD BROWN | HC SITE | REVIEW | Approved | |
| 12/11/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/13/2012 | CPIERCE1 | REJECT SHELF | Completed |