Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP12-0141
Parcel: 99999999A

Review Status: Completed

Review Details: REVISION - TENT PLAT & CORE RESUB

Permit Number - DP12-0141
Review Name: REVISION - TENT PLAT & CORE RESUB
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/14/2013 SPOWELL1 START PLANS SUBMITTED Completed
10/16/2013 RONALD BROWN H/C SITE REVIEW Approved
10/16/2013 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: The Hacienda at Wrightstown
Development Package/Rezoning (1st Revision)
DP12-0141 & C9-12-10

TRANSMITTAL DATE: October 16, 2013

DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

The following comments are based on Development Standard 2-01.0:

1. D.S. 2-01.3.8.B Your revision letter talks about the electrical easement to be abandoned, and it is also shown on detail "L" sheet C4. If this easement exists show it on the plan and indicate it is to be abandoned per sequence #______________.

2. D.S. 2-01.3.9.A The lot line line weights within the revised area do not match the other lot lines on sheets C1, C2, C3 & C5.

3. D.S. 2-01.3.9.C Sheet C1 southeast corner still shows "COMMON AREA "A"" located along the south border.

4. D.S. 2-01.3.9.O Detail "L" sheet C4 shows "15' OHE LINE BLDG. SETBACK", per your revision letter should this not be deleted?

5. Sheet C2 near the southeast corner of the site Keynote 6, block wall, is pointing at what appears to a setback line. Clarify.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

Sshield1 on DS1/planning/New Development Package/ DP12-0141

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package.
10/21/2013 LOREN MAKUS ENGINEERING REVIEW Denied DP12-0141
Tentative Plat and Grading
Haciendas at Wrightstown

1. Clarify the lot lines in the revised parts of the plans. The line weights should match the line weights on the rest of the drawing.
2. Clarify the common area location. The revision letter indicates that the southern portion of the common area is to be eliminated. Please remove the label in that area.
3. Per the revision letter, clarify the utility easements as they will be permanently recorded.
10/22/2013 KEN BROUILLETTE FIRE REVIEW Approv-Cond Fireflow required will be 1,000 GPM at 20psi residual pressure. Fire hydrants shall be located that no point of a structure is further than 400 feet from a hydrant measured from an approved route around the building. Fire Hydrant locations will be determined at time of submittal to Tucson Water for improvements.
10/25/2013 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond Revise the plans as necessary to comply with rezoning conditions related to required walls at the south, east, and west boundaries. Provide details relative to any proposed design treatments. C9-12-11
10/25/2013 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
10/30/2013 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied This review has been completed and resubmittal is required. Resubmit the following items:

1) Three rolled sets of the plans
2) All items requested by review staff
3) All items needed to approve this plan.
10/30/2013 PGEHLEN1 UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: HACIENDAS AT WRIGHTSTOWN - Lots 1-12
DP12-0141

Tucson Electric Power Company has reviewed and approves the revised Tentative Plat submitted on 10-14-13.

If you have any questions, please contact me at 917-8744.

Thank you,

Mary Burke
Right of Way Agent
Tucson Electric Power Co.
Mail Stop HQW603
PO Box 711, Tucson, AZ 85702
Office - 520-917-8744
Cell - 520-401-9895
mburke@tep.com<mailto:mburke@tep.com>

Final Status

Task End Date Reviewer's Name Type of Review Description
10/31/2013 CPIERCE1 REJECT SHELF Completed