Permit Number: DP12-0137
Parcel: 11454057F

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP12-0137
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/29/2012 CPIERCE1 START PLANS SUBMITTED Completed
10/29/2012 ELEIBOL1 ENGINEERING REVIEW Approv-Cond PDSD Engineering conditional approval pending T12SA00290 SCZ Overlay approval.
10/30/2012 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond The Protected Riparian Area shall be protected through a conservation or public easement or other legal restriction upon further development. DS 9-06.2.6

Provide the recording information for the PRA on the Site Plan, in lieu of stating "by seperate instrument" .
10/30/2012 STEVE SHIELDS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Walgreens @ 8980 E. Tanque Verde Road
Development Package (3rd Review)
DP12-0137

TRANSMITTAL DATE: October 30, 2012

DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

The following comments are based on Development Standard 2-01.0:

1. The Zoning Review Section conditionally approves the development subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development package to verify that those changes do not affect any zoning requirements.

1. D.S. 2-01.3.7.A.6 If approved provide the Overlay #T12SA00290 and the Development Standard Modification Request #DS12-11 on the plan along with: date of approval, what was approved, conditions of approval.

2. D.S. 2-01.3.9.A As this proposed project is located on two (2) parcels and cannot stand alone a lot combination will be required. Provide a copy of the approved Pima County Combination Request Form with your next submittal.

3. D.S. 2-01.3.9.L Provide the recordation information for the access easement across the parcel to the east on the plan.

4. Provide the recordation information for the proposed easement on the plan. D.S. 2-01.3.9.R A sidewalk, pedestrian circulation/accessible route, must be maintained from the existing self storage to Tanque Verde Road. If this sidewalk connection runs outside of the existing access easement a new access easement will be required.

5. Once the building plans have been submitted for review a hold can be put on the Certificate of Occupancy to issue grading.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com

Sshield1 on DS1/planning/New Development Package/ DP12-0137

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package, approved Pima County Combination Request Form. .
10/31/2012 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond Plans have been approved conditionally. Please provide revised sheets to address the conditions prior to final approval of the plans.

Final Status

Task End Date Reviewer's Name Type of Review Description
11/29/2012 PGEHLEN1 APPROVAL SHELF Completed
11/29/2012 PGEHLEN1 OUT TO CUSTOMER Completed
11/29/2012 PGEHLEN1 REJECT SHELF Completed