Permit Number: DP12-0137
Parcel: 11454057F

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP12-0137
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/27/2012 CAGUILA1 START PLANS SUBMITTED Completed
09/27/2012 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Walgreens @ 8980 E. Tanque Verde Road
Development Package (2nd Review)
DP12-0137

TRANSMITTAL DATE: September 28, 2012

DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

The following comments are based on Development Standard 2-01.0:

1. D.S. 2-01.3.7.A.6 If approved provide the Overlay #T12SA00290 and the Development Standard Modification Request #DS12-11 on the plan along with: date of approval, what was approved, conditions of approval.

2. D.S. 2-01.3.9.A As this proposed project is located on two (2) parcels and cannot stand alone a lot combination will be required. Provide a copy of the approved Pima County Combination Request Form with your next submittal.

3. D.S. 2-01.3.9.H.5.d Show how the requirements for LUC Section 3.3.9.2.A.7 are met for the long-term bicycle parking.

4. D.S. 2-01.3.9.L Provide the recordation information for the access easement across the parcel to the east on the plan.

5. Provide the recordation information for the proposed easement on the plan. D.S. 2-01.3.9.R A sidewalk, pedestrian circulation/accessible route, must be maintained from the existing self storage to Tanque Verde Road. If this sidewalk connection runs outside of the existing access easement a new access easement will be required.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com

Sshield1 on DS1/planning/New Development Package/ DP12-0137

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package, approved Pima County Combination Request Form. .
09/28/2012 RONALD BROWN ZONING HC REVIEW Approved
10/01/2012 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 10/09/2012,

SUBJECT: Walgreens At Tanque Verde and Catalina Hwy
DP12-0137, T15S, R13E, SECTION 02

RECEIVED: Development Package on September 26, 2012

The subject submittal has been reviewed and it can not be approved at this time. Prepare a detailed response that explains the revisions that were made and references the exact location in the drainage report and on the Development Package where the revisions were made:

Drainage Report:

1. The bridge shall be designed in accordance with the requirements of Section 9.5.3 of the City of Tucson Drainage Manual which requires a freeboard between the 100-year water surface elevation and the bridge low chord. The minimum freeboard shall equal 0.88(V2/2g) plus one foot. Verify that the required freeboard has been calculated and provided.
2. It appears that the southern basin bleed pipe discharge point is very close to the adjacent parcel and it might adversely impact it. Verify that the discharge concentrated flow will not cause any erosion in the property to the south.

General/Grading Notes:

1. According to Section 14.3.2 of the City of Tucson Drainage Manual, the inspection of drainage facilities needs to be conducted "at least once each year". Revise the relevant grading note to specify that inspection will be required also after every major storm. This will ensure that maintenance will be performed at the appropriate times.

Site/Grading Plan:

1. Revise the proposed bridge detail in accordance with the possible design revision requested above in the Drainage Report Comments.
2. It appears that the southern basin bleed pipe discharge point is very close to the adjacent parcel and it might adversely impact it. Verify that the concentrated discharge will not cause any erosion in the property to the south.
3. It appears that some detail callouts are not correct (e.g. E/10 and H/10 on Sheet 8/34). Revise as necessary.
4. The Perpetual Easement and Development Agreements are acceptable but they need to be recorded. Submit recorded copies of the agreements.

Mitigation Report:


1. Clarify how the information provided on Sheets 30 through 34 satisfies the requirements of D.S. 9-06.2.5.B, especially items b, c, h and i. The mitigation report shall be titled as such and it be in compliance with D.S. 9-06. and the W.A.S.H. Ordinance.


If you have any questions, I can be reached at 837-4933 or Laith.Alshami@tucsonaz.gov

RESUBMITTAL REQUIRED: Revised Development Plan Package, Drainage Report and Mitigation Report
10/05/2012 PGEHLEN1 WWM REVIEW Approved PIMA COUNTY
REGIONAL WASTEWATER RECLAMATION DEPARTMENT
201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 740-6500
DIRECTOR FAX: (520) 620-0135


October 4, 2012

To: MR. PAUL IEZZI
RICK ENGINEERING

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department


____________________________________________
From: Tom Porter, Sr. CEA (520-740-6719), Pima County Regional Wastewater Reclamation Department

Subject: WALGREENS
Development Plan - 2nd submittal
DP12-0137

The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer collection lines for the above-referenced project. The following comments are offered for your use:
The Pima County Regional Wastewater Reclamation Department hereby approves the above referenced submittal of the development plan.
10/09/2012 JOSE ORTIZ COT NON-DSD TRAFFIC Approved DP12-0137 Walgreens
Reviewd by Zelin Canchola

Resubmittal denied.

Based on methodologies described in section 5.3 (Turning Lanes) of the Transportation Access
Management Guidelines for the City of Tucson, Arizona, a separate right turn lane is warranted at
the eastern driveway.
10/10/2012 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond The Protected Riparian Area shall be protected through a conservation or public easement or other legal restriction upon further development. DS 9-06.2.6

Provide the recording information for the PRA on the Site Plan.
10/11/2012 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied This review has been completed. Resubmittal required.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/17/2012 FERNE RODRIGUEZ OUT TO CUSTOMER Completed