Permit Number: DP12-0132
Parcel: 11504485A

Address:
1031 N PARK AV

Review Status: Completed

Review Details: DEV PKG - REVISION

Permit Number - DP12-0132
Review Name: DEV PKG - REVISION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/05/2014 PGEHLEN1 START PLANS SUBMITTED Completed
08/05/2014 GARY WITTWER COT NON-DSD TDOT Approved
08/06/2014 ELEIBOL1 ENGINEERING REVIEW Reqs Change REVIEWER: Elizabeth Leibold P.E., Engineering and Floodplain As-built Review
SUBJECT: Park Avenue Housing Campus Acquisitions
LOCATION: T14S, R14E, SECTION 07
ACTIVITY: DP12-0132-R2

The revised Development Package submittal, including Final Revised Grading Plan, has been expedited and reviewed. PDSD Engineering does not recommend approval until as-builts reflect all completed improvements and safe alley access has been provided and accepted by TDOT. Address the following comments for Final CofO.
FINAL REVISED GRADING PLAN - AS-BUILT COMMENTS:
1) Tech Man Sec.2-01.13: The as-built / "Final Revised Grading Plan" submittal of 6AUG14 is missing the following information:
a) The substantial completion letter(s) prepared by EOR. To complete the package for the grading permit project closure documentation, provide: (one copy and one original) letters of completion (one for drainage improvements, and another letter for substantial completion of overall project).
b) Grading permit project closure as-built documentation shall include: any missing easement documents, missing sequence numbers for the easements labeled on plans sheet 8, including access easement near alley area as approved on PIA revision and based on accepted easements and license agreements.
2) Tech Man Sec.2-01.12.7: As-builts do not reflect what was constructed. Sheet 15 indicates that the alley width was to be reconstructed along south entrance area to provide a 20-ft skewed opening however field visits indicate that the construction is incomplete. T12PI00009 does not show that the inspection was approved, however there was correspondence indicating that TDOT may have approved alley width and configuration although construction has not been completed for the south alley entrance area (west curb). EOR shall explain discrepancy, show completed as-built curb alignment after reconstruction.

After the remaining improvements have been constructed and all remaining documents have been resubmitted and reviewed, a copy of the as-builts will be provided to PDSD Engineering Inspector for final grading inspections. If you have questions, call me at 837-4934 or email me at elizabeth.leibold@tucsonaz.gov

Elizabeth Leibold, P.E., CPM, CFM
Civil Engineer
Engineering Division
Planning & Development Services Department
City of Tucson
08/06/2014 KBROUIL1 COT NON-DSD FIRE Approved
08/06/2014 LEERAY HANLY ZONING HC REVIEW Completed
08/06/2014 ANDREW CONNOR LANDSCAPE REVIEW Approved
11/10/2014 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change per comments
11/10/2014 PGEHLEN1 COT NON-DSD TRAFFIC Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
11/10/2014 PGEHLEN1 APPROVAL SHELF Completed
11/10/2014 PGEHLEN1 OUT TO CUSTOMER Completed
11/10/2014 PGEHLEN1 REJECT SHELF Completed