Permit Number: DP12-0127
Parcel: 135084630

Address:
1345 S KOLB RD

Review Status: Completed

Review Details: SITE and/or GRADING

Permit Number - DP12-0127
Review Name: SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/01/2012 RBROWN1 ADA REVIEW Passed
08/16/2012 STEVE SHIELDS ZONING REVIEW Approved
08/16/2012 SSHIELD1 PLUMBING-COMMERCIAL REVIEW Passed
08/16/2012 SSHIELD1 LANDSCAPE REVIEW Passed
08/16/2012 SSHIELD1 NPPO REVIEW Passed
08/16/2012 SSHIELD1 H/C SITE REVIEW Passed
08/22/2012 LOREN MAKUS ENGINEERING REVIEW Denied Revise the drainage statement floodplain delineation. The aerial photos of the site show a curb island and solid waste container enclosure upstream of cross-section 4. Revise the analysis to include a cross section at these obstruction and upstream of them as well. (SMDDFM Fig. 5.1)

Provide details of the fence design to demonstrate that the clear openings in the area affected by the regulatory flows. Show how the gates will respond to potential clogging by debris carried downstream from the subdivision areas. Discuss the use of break-away latches or some other means for preventing adverse effects caused by clogging.
08/29/2012 MARTIN BROWN FIRE REVIEW Approv-Cond All manual and automatic gates are required to comply with local amendments from the 2006 IFC Section 503.6. The man gates for firefighting access to exterior walls shall also be capable of being opened by fire personnel.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/05/2012 CPIERCE1 OUT TO CUSTOMER Completed