Permit Review Detail
Review Status: Completed
Review Details: SITE and/or GRADING
Permit Number - DP12-0126
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/03/2012 | RBROWN1 | ADA | REVIEW | Passed | |
| 08/09/2012 | RONALD BROWN | H/C SITE | REVIEW | Denied | 1. As per table 1106.1, a total of 5 accessible parking spaces are required for a total available of 116. You have four accessible spaces shown in your site plan. a. Please add another accessible parking space meeting all the requirements of the 2006 IBC, Section 1106 and ICC A117.1, Section 502. 2. Of those 4 spaces shown, only two have accessible aisles as required by ICC A 117.1, Section 502.4. Please redesign those two non-compliant accessible parking spaces and provide accessible parking aisles. 3. For all accessibnle parking spaces insure code compliance as to slopes, sizes, aisles, signage, markings and access to the accessible routes. Contact COT Department of Transportation for signage and marking requiremenmts. END OF REVIEW |
| 08/20/2012 | JASON GREEN | ENGINEERING | REVIEW | Approved | DP Package approved as an "As-built" plan for existing conditions onsite. Per the Zoning Determination Letter and request from Glenn Moyer the applicant provided a plan that shows existing conditions inorder to facilitate future development of the property. JG |
| 08/23/2012 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 08/23/2012 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 08/27/2012 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 08/28/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Revise the site drawing to legibly include the following information: a. the location and size of the water meters and backflow preventers b. the location of the main water lines and fire hydrants c. the locations of the gas meters d. the location and size of the public sanitary sewer e. the locations of the building connections to the public sewer f. the location, invert, and rim elevation of the upstream and downstream manholes g. the first floor elevation for the buildings Reference: City of Tucson Development Standard No. 2-01.0.0, Section 3.8 D and Section 103.2.3, UPC 2006. |
| 08/29/2012 | MARTIN BROWN | FIRE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/08/2012 | CPIERCE1 | OUT TO CUSTOMER | Completed |