Permit Number: DP12-0123
Parcel: 141011530

Address:
5278 S CIVANO BL

Review Status: Completed

Review Details: RESUB - SITE and/or GRADING

Permit Number - DP12-0123
Review Name: RESUB - SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/25/2012 RONALD BROWN ADA REVIEW Passed
08/06/2012 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
DP12-0123 (T12CM03813)
5278 S Civano Blvd
Conversion of first floor of SFR to Food Service, and
second and third floors to be single-family residence.


TRANSMITTAL: August 6, 2012


COMMENTS: This project is review per Development Standards Number 2-01 for a Development Package. Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


1) This site is located in the Neighborhood Center District of Civano I (F-3.3.1). The Zone is PAD 12. The use is Food Service, under the Commercial Services Use Group (F-3.3.1.a) and is subject to Section 3.5.4.6.D in the Land Use Code.

2) This project is with PAD 12. Provide a reduced-scale map of the PAD District on the plan. Indicate the location of the site being developed on the map (DS 2-01.3.6).

3) Cleary depict all existing a proposed utilities on the site plan (DS 2-01.3.7.D).

4) Show on-sit pedestrian circulation as required by the LUC (3.2.8.4.B) and design criteria in Development Standard 2-08.0 and the Uniform Building Code (DS 2-01.3.9.R). Within the pedestrian circulation path, an accessible route is required (DS 2-08.3.1). Note that the plot plan for the SFR show steps that do not appear on this DP.

5) The minimum bicycle parking required is two (2) short term (FKA Class 2) Food Service (LUC Section 3.3.8) with a forty percent (40%) increase in Civano Neighborhood I (Civano 1 F- 3.4) for a total of three (3) short-term bicycle parking spaces required (SD2-01.3.9.H.5.d). Revise the parking calculations. Provide the parking calculation sheet in the same size as the site plan (24 by 36 inches).

6) Provide a copy of the floor plan for the restaurant and the residence (2-01.3.7.8.a). Are the patios to be used as outdoor dinning?

Note: Additional comments may be necessary relative to information provided on future submittals.
08/06/2012 ANDREW CONNOR LANDSCAPE REVIEW Approved
08/07/2012 ANDREW CONNOR NPPO REVIEW Approved
08/08/2012 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Approv-Cond PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

DP12-0123 Harriet's Café 8/8/12

() Final Plat
(X) Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other -

CROSS REFERENCE:

NEIGHBORHOOD PLAN: Civano PAD

GATEWAY/SCENIC ROUTE: No

COMMENTS DUE BY: 8/22/12

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

Approved-Conditionally per Zoning Review and Approval.

(X) No Resubmittal Required:
() Final Plat
() Development Plan
() Landscape Plan
() Other -


REVIEWER:JB 837-6966 DATE: 08/8/12
08/14/2012 KEN BROUILLETTE FIRE REVIEW Approved
08/17/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Revise the site drawing to include the following information:
a. the location of the gas meter (if one exists or is planned)
b. the invert and rim elevation of the upstream and downstream manholes
c. the first floor elevation for the building
Reference: City of Tucson Development Standard No. 2-01.0.0, Section 3.8 D and Section 103.2.3, UPC 2006.
08/17/2012 RONALD BROWN HC SITE REVIEW Denied 1. Need to show accessibility from the side walk through the front door entrance.
a. Additional accessibility requirements will need to be shown when building permit is accquired for the restaurant.
END OF REVIEW