Permit Review Detail
Review Status: Completed
Review Details: RESUB - SITE/GRADING ALL
Permit Number - DP12-0115
Review Name: RESUB - SITE/GRADING ALL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/11/2012 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Gene Goldstein DATE: November 05,2012 6255 N. Camino Pineria Aria FROM: Paul Machado Tucson, Arizona 85718 Engineering Division Subject: 2904 N. 1st Ave, USA PAWN Development Package, DP12-0115 (Second Review) T13S, R14E, Section 31 RESUBMITTAL REQUIRED: Development Package and Drainage Statement The Development Package (DP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Development Package: 1. Please include a response letter to the comments along with the corrected copies of the DP. 2. Per the redlines included in the previous review, the new 6' sidewalk along 1st Avenue shall be constructed adjacent (back of curb) to the existing curb per TDOT. If the curb remains as shown now, half in the R/W and half on private property, then a public pedestrian easement for the portion of the sidewalk on private will be required. Also at the scale the plan is drawn it is difficult understand what is being proposed in the area of the sidewalk. Perhaps a detail as shown on the landscape plans is warranted. 3. Per the redlines included in the previous review, site plan keynote no. 28 was supposed to be corrected. Extruded curb is not allowed in the R/W and the new curb shall be called out using COT standard detail numbers, i.e.: COT SD 209, Type I, (if applicable). 4. Include the elevation, with the field book and page, on note "A", the Basis of Elevation. If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson - Planning and Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/ 2904 N. 1st Ave DP 2 |
10/25/2012 | RONALD BROWN | H/C SITE | REVIEW | Denied | 1. Please show slope of new concrete accessible route detail 1/2 of 3 in compliance with ICC A117.1, Section 403.3. END OF REVIEW |
10/31/2012 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
11/01/2012 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
11/02/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Revise the site drawing to include the first floor elevation for the building Reference: City of Tucson Development Standard No. 2-01.0.0, Section 3.8 D and Section 103.2.3, UPC 2006. |
11/05/2012 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved |