Permit Review Detail
Review Status: Completed
Review Details: SITE and/or GRADING
Permit Number - DP12-0102
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/16/2012 | RBROWN1 | ADA | REVIEW | Passed | |
| 07/24/2012 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
| 07/27/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Revise the site drawing to include the following information: a. the location and size of the water meter and backflow preventer b. the location of the main water lines and fire hydrants c. the location of the gas meter (if one exists or is planned) d. the location and size of the public sanitary sewer e. the location of the building connection to the public sewer f. the location, invert, and rim elevation of the upstream and downstream manholes and cleanouts Reference: City of Tucson Development Standard No. 2-01.0.0, Section 3.8 D and Section 103.2.3, UPC 2006. |
| 07/30/2012 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 07/31/2012 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 08/02/2012 | RONALD BROWN | H/C SITE | REVIEW | Denied | 1. The slope from the top of the new sidewalk to Craycroft Road is greater than 5% and must meet the requirements of a ramp and comply with ICC A117.1, Section 405 complete with handrails. a. Provide a handrail elevation in accordance with ICC A117.1, sections 405.9 and 505.10.1. 2. Provide detectable warning strips at both ends of the marked crossing as required by ICC A117.1, section 406.12, 13 and 14. 3. Delete the non-compliant (in the asphaltic paving) and provide a concrete ramp in the concrete walkway that complies with ICCA 117.1, section 406. complete with a detectable warning strip. 4. Neither accessible parking asile ramps are compliant. Provide ramps that comply with ICCA 117.1, section 406. 5. Provide large scale details of all the different types of ramps showing all accessible requirements such as: dimensions, elevations, slopes, detectable warning strips as required and handrails as required. Reference ICC A117.1, sectios 405 and 406. 6. Provide large scale details of the accessible parking layouts showing all accessible requirements such as: dimensions, elevations, grade slopes, markings, signage, ramps, "Van Accessible" spaces and etc. a. Provide a large scale sign detail including "Van Accessible" identification as per COT DOT requirements. 7. Zoning will require pedestrian pathways to both 5th Street and Baker Street right of ways. Reference Zoning comments. These must be accessible. a. Provide all marked crossings as required. b. Provide all ramps and handrails as required. c. All new accessible routes slopes are to comply with ICC A117.1, Section 403.3; 5% max running slope, 2% max cross slope. END OF REVIEW |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/13/2012 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |