Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP12-0101
Parcel: 13106029C

Review Status: Completed

Review Details: RESUB - SITE and/or GRADING

Permit Number - DP12-0101
Review Name: RESUB - SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/06/2012 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: McDonald's - 2525 S. Craycroft Road
Development Package (2nd Review)
DP12-0101

TRANSMITTAL DATE: December 6, 2012

DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

Provide a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed with your next submittal.

Address the following comments on you next submittal and submit a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

As these plan s have not been approved remove all revision clouds from the plan.


The following comments are based on Development Standard 2-01.0:

1. This comment was not fully addressed. Provide the Section, township, and range; section corners. D.S. 2-01.3.4 The location map shown on sheet CV does not meet the requirements of D.S. 2-01.3.4. Review D.S. 2-01.3.4 and provide a location map on the cover sheet for the development package.

2. This comment was not addressed. D.S. 2-01.3.8.B Provide the recordation information for the "ELECTRICAL EASEMENT" shown in the northeast corner of the plan.

3. This comment was not addressed. D.S. 2-01.3.9.F All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined.

4. The sight visibility triangles are not correct contact the PDSD Engineering reviewer for correct SVT's. D.S. 2-01.3.9.H.5.2 Show existing and if applicable future sight visibility triangles. On a designated MS&R street, the sight visibility triangles are based on the MS&R cross-section.

5. This comment was not addressed. D.S. 2-01.3.9.H.5 As a parking lot restripe is proposed provide access lane and parking area access lane width dimensions for all proposed and existing access lane and parking area access lanes this includes the northern most drive thru lane.


6. This comment was not addressed. D.S. 2-01.3.9.H.5.a Per LUC Table 3.3.6.4.A.II 60 degree parking the required "C" Space depth is 19.8', the plan shows 18'-0".

7. This comment was not addressed. D.S. 2-01.3.9.H.5.a There is a vehicle parking space shown at the northwest corner of the site that appears to encroach into an existing site wall. Demonstrate on the plan how removal/relocating of the wall will be addressed.

8. This comment was not addressed. D.S. 2-01.3.9.H.5.a The provided vehicle parking space calculation is not correct. Sheet CV shows a total floor area of 4,623 sq. ft. That said the required number of vehicle parking spaces is 46. Based on the provided vehicle parking calculation 41 spaces provided requires a Board of Adjustment for Variance.

9. This comment was not addressed. D.S. 2-01.3.9.H.5.d Per LUC 3.3.8.2.B COMMERCIAL SERVICES USE GROUP, Communications, the required Short-term Bicycle parking is 2, and the required Long-term Bicycle parking is based on 1 space per 12,000 sq. ft. GFA. Minimum requirement is 2 spaces. That said the minimum required for Short & Long term bicycle parking is two (2) spaces each. Provide a bicycle parking space calculation that provides the number required and provided for both Short & Long term bicycle parking.

10. This comment was not addressed. D.S. 2-01.3.9.Q Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building

11. This comment was not addressed. D.S. 2-01.3.9.W All proposed signage shown on sheets SD.1 & SD,2 will require separate permits. Provided a note on the plan stating that "ALL PROPOSED SIGNAGE REQUIRES A SEPARATE PERMIT."

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com

Sshield1 on DS1/planning/New Development Package/ DP12-0101

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package, Comment response letter.
12/19/2012 RONALD BROWN HC SITE REVIEW Denied RESUBMITTAL COMMENTS IN ALL CAPS

1. OK

2. Detectable warning strips are not required at accessible parking aisles. These areas are safe zones.
DETECTABLE WARNING STRIPS WERE NOT REMOVED ON SHEET SP-1

3. OK

4. OK

5. OK

6. OK

7. OK

ADDITIONAL COMMENT
8. At detail 8/SD2:
a. Signage is to be as per COT DOT standards. Bottom of main sign to be 7'-0" min. The fine pentalty is shown on main sign and is not a separate added sign.
END OF COMMENTS
12/20/2012 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change Identify all screening elements and walls on the site plan DS 2-07.2.2.

Ensure that all Engineering and Zoning comments and concerns are addressed prior Landscape approval stamp.
12/27/2012 PAUL MACHADO ENGINEERING REVIEW Denied To: URS Corporation DATE: December 27, 2012
1255 Broad St., Ste. 201 FROM: Paul Machado
Clifton, NJ, 07013 Engineering Division

Subject: McDonalds, 2525 S. Craycroft Rd.
Development Package, DP12-0101 (Second Review)
T14S, R14E, Section 24

RESUBMITTAL REQUIRED: Development Package and Drainage Statement

The Development Package (DP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Development Package:

NOTE: A response letter nor the "redlines" were included with the re-submittal. It also appears that not all comments were addressed. See comments 23 and 24. Additional comments may be forth coming depending on the revisions to the plan.

1. Please include a response letter to the comments along with the corrected copies of the DP.
2. I have called your office twice in order to facilitate the approval of this project. However I have not received a reply phone call. Please call me if you need any clarification on any of my comments.
3. All lettering and text (upper or lower case), and numbering, shall be a minimum of 3/32 inches in height to assure the plan will be legible during review and when digitized and/or reduced for archiving. D.S. 2-01.2.3.
4. A legend that shows and describes all symbols used on the drawing is to be provided, preferably on the first sheet. D.S. 2-01.2.9. Some of the material indications are not shown on the Legend. Double check the list for what's shown on the plans.
5. The project-location map shall cover approximately one (1) square mile, be drawn at a minimum scale of 3" = 1 mile, and provide the following information. D.S. 2-01.3.4.
A. Show the subject property approximately centered within the one (1) square mile area.
B. Identify major streets and regional watercourses within the square mile area and all streets that abut the subject property.
C. Section, township, and range; section corners; north arrow; and the scale will be labeled.
6. Existing Site Conditions. The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within fifty (50) feet of the site. On sites bounded by a street with a width of fifty (50) feet or greater, the existing conditions across the street will be provided. D.S. 2-01.3.8.
B. All easements shall be drawn on the plan. The recordation information, location, width, and purpose of all easements on site will be stated. Blanket easements should be listed in the notes, together with recordation data and their proposed status. Should an easement not be in use and be proposed for vacation or have been abandoned, so indicate. However, should the easement be in conflict with any proposed building location, vacation of the easement shall occur prior to approval of plan unless written permission from easement holder(s) is provided.
C. The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks.
E. Indicate the ground elevation on the site based on City of Tucson Datum (indicate City of Tucson field book number and page). Elevations along with the Book and Pages can be found at: http://maps.tucsonaz.gov/pdsd/index.html
G. Other significant conditions on the site, such as major rock outcrops, structures, fences, walls, curbs etc., shall be shown. These elements should be indicated in a different line weight than the proposed improvements and labeled "to be removed" or "to be retained." It is not clear what parts of the site will be removed or retained. Use additional "schedule numbers" to achieve this. It is not clear what curbs stay or go.
7. Information on Proposed Development. The following information on the proposed project shall be shown on the drawing or added as notes. D.S. 2-01.3.9.
H. Proposed traffic circulation:
2. Show future and existing sight visibility triangles. On a designated MS&R street, the sight visibility triangles are based on the MS&R cross-section. For a 150' R/W the face of curb (FOC) location is 12' from the R/W line.
3. Indicate fire circulation, including accessibility and vehicle maneuverability. Perhaps the refuse enclosure would be better skewed so the service vehicle has a straighter approach and back-up. Revise as required.
J. If street dedication is not required or proposed and the project site is adjacent to a Major Street or Route, draw the Major Street right-of-way lines for those streets. (Add the MS&R future sidewalk, right-of -way lines, sight visibility triangles, etc.)
N. In conjunction with a drainage report or statement, as applicable, prepared in accordance with the City Engineer's instructions and procedures, the following information will be indicated on the development package documents. For additional information regarding drainage standards, see the City of Tucson Standards Manual for Drainage Design and Floodplain Management.
7. Draw locations and indicate types of off-site runoff acceptance points and/or onsite
run-off discharge points.
O. All applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown.
22. Include a compact disk (CD) containing the latest/revised submittal of the dev. plan, reports and documents associated with this project with the latest re-submittal.
23. Additional "redline" comments are shown on the plan itself. Correct the plans as indicated on the hard copy set and return them with the corrected set.
24. It is suggested that while my comments are being addressed or have been addressed, that you make an appointment/call/email me to discuss any of my comments that you may have questions on. If I missed any information or made a mistake, we can go over those items at the meeting, over the phone or through email. Do not hesitate to call if there are any questions or disagreements on my comments as you address them.


Drainage Statement:
1. Please include a response letter to the comments along with the corrected copies of the DS.
2. Per previous comment, a DS is required on the re-submittal.
3. A Drainage Statement is a brief description of drainage conditions applicable for a site which are not affected by 100 year flows of 100 cfs, of more……per S.M.D.D.F.M., chap. II, 2.1.2. The DS must be submitted along with the site plan and accepted with the approval of the grading plan.
4. The content and format of the Drainage Statement should follow S.M.D.D.F.M., chap. II, 2.2.
5. Show the project address or administration address on the cover sheet of the DS.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson - Planning and Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/2525 S. Craycroft Rd._DP_3

Final Status

Task End Date Reviewer's Name Type of Review Description
07/18/2013 CPIERCE1 OUT TO CUSTOMER Completed
07/18/2013 CPIERCE1 REJECT SHELF Completed