Permit Review Detail
Review Status: Completed
Review Details: SITE and/or GRADING
Permit Number - DP12-0091
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/03/2012 | RONALD BROWN | H/C SITE | REVIEW | Passed | |
| 07/09/2012 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Denied | DATE: July 17, 2012 TO: Jeff Biggs, Administrator, Tucson Water, 310 West Alameda, Tucson 85747 SUBJECT: Tucson Water 1-, 4-Dioxane Treatment Plant Engineering Review ADDRESS: 1100 W IRVINGTON RD LOCATION: T14S, R13E, Section 35 REVIEWER: Elizabeth Leibold, P.E. FLOODPLAIN INFO: FIRM Panel: 040192286L (effective date 16JUN11), SFHA zone: X ACTIVITY NUMBERS: DP12-0091, T12CM03552 SUMMARY: PDSD Engineering Division has reviewed the plan set and does not recommend approval until the following comments are addressed. This project involves an additional treatment facility to be built at an existing Tucson Water treatment site. Meetings were held to discuss project 29JUN12, 16JUL12. This project falls under exemption 26-4(2) & (3) of the Floodplain Ordinance and is exempt from Riparian Floodplain Report requirements. Proposed new building and equipment are to be elevated to a minimum of Regulatory Flood Elevations. A floodplain use permit and elevation certificates will be generated. COMMENTS: 1) Tuc Code Sec.26-11.2(b): Address the following comments: A) The package had an old design layout so sheets C-1, detail sheet(s), and Site Plan sheet need to be updated to reflect revised, pending resubmittal of revised drainage report as discussed in meeting 16JUL12. B) Show channel details on C-1 or detail sheet(s). Provide cross sections, dimensions on planviews, and details for the typical channel section, entrance and outlet areas of the channel, existing outlet structure on planview, and other details/sections sufficient for construction and inspections. C) Provide documentation from Pima County allowing the improvement if within Pima County jurisdiction for park or other requirement. D) Show parcel limits on Site Plan and Grading Plan. E) Any proposed easements that are located outside of the parcel limits, for drainage construction and maintenance, access easement, and/or landscape easement on Block 1, shall be shown and labeled with sequence number or dkt/pg. F) Resubmit 2 copies of Grading and site plans with floodplain use permit application, 2 copies of the revised drainage report and response letter. If you would like to schedule a meeting to go over the next submittal or have any questions, call me at 837-4934. Elizabeth Leibold, P.E., CPM, CFM Civil Engineer Engineering Division Planning & Development Services Department |
| 07/12/2010 | ELIZABETH LEIBOLD | PLUMBING-COMMERCIAL | REVIEW | Denied | Revise the site drawing to include the following information: a. the location and size of the water meter and backflow preventer (coordinate the locations with the plumbing plans) b. the location of the building connection to the public sewer c. the location, invert, and rim elevation of the upstream and downstream manholes and cleanouts Reference: City of Tucson Development Standard No. 2-01.0.0, Section 3.8 D and Section 103.2.3, UPC 2006. |
| 07/17/2012 | RBROWN1 | ADA | REVIEW | Approved | |
| 07/18/2012 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 07/18/2012 | JOE LINVILLE | NPPO | REVIEW | Approved | |
| 07/19/2012 | KEN BROUILLETTE | FIRE | REVIEW | Approv-Cond | All storage and use of hazardous materials will subject to the 2006 IFC and associated NFPA Standards. Permits will be required for hazardous materials storage and use. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/24/2012 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |