Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: DP12-0088
Parcel: 113100010

Address:
1545 E COPPER ST

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP12-0088
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/01/2012 GBONILL1 START PLANS SUBMITTED Completed
08/02/2012 JASON GREEN ENGINEERING REVIEW Approved
08/03/2012 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: DP12-0088
Salpointe High School - Softball Field and Sidewalk improvements
Development Package

TRANSMITTAL DATE: August 3, 2012

DUE DATE: July 6, 2012

COMMENTS: Zoning has denied the plan on this review because it is clear that the sidewalk issue has not been completely resolved and may require additional dialogue between the consultant and John Beall and other PDSD staff. See comments below, address and revise the plans as requested. Zoning will review the changes when resubmitted for stamps to assure that the changes requested have been made.

1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is June 6, 2013.

2. The material listed for the pedestrian path on sheet 6 of the DP is not an approved material for accessible routes. Per discussion with John Beall and as indicated to the consultant DG is not an approved material for accessible routes. The pedestrian path must be constructed of concrete cement or similar material with smoothness, hardness and durability. Several emails between PDSD staff and the consultant have been exchanged with regards to what would be acceptable for an accessible route.

It is acknowledged that a concrete sidewalk was added to the plan but only to the new facilities of the softball field. The new DG path to the baseball field is still proposed and is indicated as a pedestrian path. A 4' wide concrete sidewalk adjacent to the path that leads to the baseball field facilities must be added.

Previous Comment no. 4: DS 2-01.3.8.R - DG is not an approved material for pedestrian sidewalks. Per the PAD, page 65 pedestrian facilities are to be accessible. DG is not approved as a material that provides for accessible routes. The PAD is silent on material to be used for pedestrian facilities and therefore defaults back to the Land Use code or Development Standards. DS 2-08 requires that all sidewalks must be constructed of concrete or similar materials in hardness and durability. Revise the type of material to be used for the new pedestrian facilities proposed on this plan.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

DGR C:\planning\cdrc\developmentplan\DP12-088dp3.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan
08/08/2012 RONALD BROWN ZONING HC REVIEW Approved
08/09/2012 MPADILL1 URBAN PLANNING REVIEW Approved PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

DP12-0088 Salpointe Catholic High School (Softball Field)

() Tentative Plat
(X) Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other - Elevations

CROSS REFERENCE: Salpointe Catholic High School PAD -17

NEIGHBORHOOD PLAN: Salpointe Catholic High School PAD -17

GATEWAY/SCENIC ROUTE: NO

COMMENTS DUE BY: August 29, 2012

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies with Plan Policies
() See Additional Comments Attached
(X) No Additional Comments - Complies With Planning Comments Submitted on: 07/09/12
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other


REVIEWER:msp 791-5505 DATE: 08/09/12
08/09/2012 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied Review has been completed. Resubmitted required documents when changes have been made to plans.

Final Status

Task End Date Reviewer's Name Type of Review Description
08/09/2012 CPIERCE1 OUT TO CUSTOMER Completed