Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP12-0075
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/14/2012 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 06/18/2012 | MARTIN BROWN | COT NON-DSD | FIRE | Approved | |
| 06/21/2012 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: June 21, 2012 SUBJECT: 1 E Broadway Development Plan Package- 2nd Engineering Review TO: Caylor Construction Company; Attn: Rob Caylor LOCATION: 1 E Broadway Blvd, T14S R13E 12/13 Ward 6 REVIEWERS: Jason Green, CFM ACTIVITY: DP12-0075 SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the proposed Development Plan Package, Drainage Statement (Cypress Civil Development, 18MAY12) and Traffic Impact Statement (Cypress Civil Development, 07MAY12). Engineering Division does not recommend approval of the Development Plan Package at this time. This review falls under Development Standard 2-01. All comments reflect Site Plan and Grading Plan. The following items need to be addressed: SITE PLAN: Remove all clouds from the development plan document. The final copies of the development package should be clean and without any revision clouds. At this point the revision clouds are not needed as this plan has not been approved and the site has not been developed. 1) Completed. 2) Completed. 3) Restated: DS Sec.2-01.3.9.H.2: It is acknowledged that a Development Standard Modification Request (DS12-05) has been submitted, and approved by PDSD, to use the smaller dimensions for the proposed SVT's as shown on the development plan document. However the development plan document must still include a note listing the DSMR Case #, date of approval and any associated conditions if applicable. 4) Acknowledged. GENERAL COMMENTS: Please provide a revised Development Plan Package that addresses the comment provided above. For expedite purposes the development plan package can be reviewed over the counter (PDSD Engineering Division comment only) for stamp approval once all items have been addressed. Please call to schedule an appointment when ready. For any questions or to schedule meetings call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Planning & Development Services Department |
| 06/25/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 06/26/2012 | TERRY STEVENS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: DP12-0075 1 E. Broadway Blvd. Development Package TRANSMITTAL: 06/27/2012 DUE DATE: 06/28/2012 COMMENTS: 1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development package. If, at the end of that time, the development package has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development package is 05/21/2013. 2. This project will require a special application submittal and approval for the Infill Incentive District - Core. As a general note provide the case number, date of approval, what was approved and any conditions of approval on the plan. Contact Adam Smith with PDSD. Add the Special Application number (T12SAXXXXX) to all sheets near the lower right corner. 3. This project will require a submittal and approval for a temporary revocable easement (TRE) for the sunshade (keynote #7) and the canopy (keynote #8) which are encroaching into the right of way and the short term bicycle parking in the right of way. Provide documentation of approval. Contact Jim Rossi with City of Tucson Real Estate Division. 4. DS Sec.2-01.3.9.H.2: It is acknowledged that a Development Standard Modification Request (DS12-05) has been submitted, and approved by PDSD, to use the smaller dimensions for the proposed SVT's as shown on the development plan document. However the development plan document must still include a note listing the DSMR Case #, date of approval and any associated conditions if applicable. 4. DS 2-01.3.7.A.9.b The Family Dwelling Use with a "X" development designator requires a maximum lot coverage of 80%. Provide allowed and proposed lot coverage calculations. This comment shall remain until the lot coverage, parking requirements, etc. haved been waived by the IID submittal. 5. Remove all clouding and references to revision delta 1. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 TLS C:\planning\cdrc\developmentpackage\DP12-0075dp.doc |
| 06/27/2012 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 06/28/2012 | PGEHLEN1 | ENV SVCS | REVIEW | Denied | pending approval of the MDR for the dumpsters. |
| 06/28/2012 | PGEHLEN1 | ENV SVCS | REVIEW | Denied | "ESD approves the proposed plans." per MDR T12SA00233/ MDR 12-02. |
| 07/10/2012 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES July 10, 2012 Rob Caylor Caylor Construction Company 6422 E. Speedway Blvd. #130 Tucson, Arizona 85710 Subject: DP12-0075 1 E BROADWAY Development Plan Dear Rob: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made please submit the following documents for sign-off. 1 Rolled COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews. 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. Additional print copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your prints to the CDRC office for sign-off approval. The printing company will deliver the original rolled prints to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. Plans will not be signed and released until the CDRC office has been notified by PC Addressing that all fees for this plan have been paid. The CDRC office will need this confirmation in writing. A Development Plan remains valid for a period of three (3) years from the date of approval. This Development Plan will expire on 07/10/15 per LUC 5.3.8.2.B. PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html. BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. Should you have any questions, please call me at 837-4893. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via Email: ROB@CAYLOR.NET |
| 07/10/2012 | GARY WITTWER | COT NON-DSD | TDOT | Approved | I do not have any comments. Looks good to go. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/30/2012 | PGEHLEN1 | APPROVAL SHELF | Completed |
| 07/30/2012 | PGEHLEN1 | OUT TO CUSTOMER | Completed |
| 07/30/2012 | PGEHLEN1 | REJECT SHELF | Completed |