Permit Number: DP12-0069
Parcel: 13815014G

Address:
434 W LERDO RD

Review Status: Completed

Review Details: REVISION - SITE

Permit Number - DP12-0069
Review Name: REVISION - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/08/2013 TERRY STEVENS ZONING REVIEW Passed
04/17/2013 MARTIN BROWN FIRE REVIEW Approved
04/23/2013 LOREN MAKUS ENGINEERING REVIEW Approved
04/24/2013 RONALD BROWN H/C SITE REVIEW Denied 1. Please indicate on the large scale floor plan where Detail "A", Cross Section is cut.
2. At the detail entitled "Ramp Grading Detail":
a. Please provide an alphabetical identification of "D".
b. The grade elevations shown on the higher landing, 11.07 TC, conflict with the same elevations shown on the site plan of 12.00 TC. If 11.07 TC was to remain the landing slope would be non compliant a with a slope of 14%. Reference ICC A 117.1, section 405.
c. Please provide all dimensions of the ramp and sidewalk.
d. Please provide a handrail elevation compliant with ICC A117.1, Section 405.8 and 505.
END OF REVIEW
04/26/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied The revision to the first floor elevation of the new classroom building has resulted in the first floor elevation (2609.77') being less than 12" above the rim elevation of the next upstream sanitary manhole (2609.10'). Provide a backwater valve for the building sewer per Section 710.1, UPC 2006, as amended by the City of Tucson.
04/29/2013 ANDREW CONNOR LANDSCAPE REVIEW Passed
05/01/2013 ANDREW CONNOR NPPO REVIEW Passed