Permit Number: DP12-0061
Parcel: 99999999A

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP12-0061
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/14/2012 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
06/29/2012 TERRY STEVENS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Terry Stevens
Lead Planner

PROJECT: DP12-0061
9193 E. Old Spanish Trail
Development Package

TRANSMITTAL DATE: 07/05/12

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This project cannot be approved until the final plat, S12-017, has been completed and approved.

2. DS2-01.3.9.O Provide a dimension from the proposed carport covers to the back of future curb along Old Spanish Trail. The indicated distance of 20.5' does not meet the required distance of 21' from the back of future curb.

3. The above comments are minor in nature and can be reviewed over the counter by setting an appointment with me.


If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

C:\planning\cdrc\DSD\DP12-0061-2.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
07/06/2012 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
07/09/2012 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 2ND FL
TUCSON, AZ 85701-1207

AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: DP12-0061 THE PLACE AT PRESIDIO TRAIL/REVISED DEVELOPMENT PLAN
DATE: July 3, 2012



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

1. On all title blocks include the apartment and building numbers.
07/11/2012 RONALD BROWN HC SITE REVIEW Denied 1. As depicted in fugure 307.4, reduced vertical clearance does not restrict access just to the back side of a stair but as shown it also includes possible access from the side of the stairs. The situation is prevelant in several stair designed layouts. Please provide the barriers as required in all of these situations.
2. At detail H/16:
a. Please provide for "Van Accessible" parking spaces as required by the 2006 IBC, Section 1106.7 and ICC A117.1, Section 502.2. Provide the proper wide as required.
END OF REVIEW
07/13/2012 JOE LINVILLE NPPO REVIEW Approved
07/13/2012 LOREN MAKUS ENGINEERING REVIEW Approv-Cond July 13, 2012
DP12-0061
The Place at Presidio Trails
Development Package review

The Engineering Section recommends approval of this development package with the following conditions:

1. The Plat S12-017 must be approved by Mayor and Council and recorded.
2. A WASH overlay review must be approved.

Loren Makus, EIT
Senior Engineering Associate
07/13/2012 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond Subject to approval of WASH application associated with construction of the sewer line.
07/16/2012 TIM ROWE PIMA COUNTY WASTEWATER Approved PIMA COUNTY
REGIONAL WASTEWATER RECLAMATION DEPARTMENT
201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 740-6500
DIRECTOR FAX: (520) 620-0135


June 19, 2012

To: TRI MILLER
RICK ENGINEERING

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department


____________________________________________
From: Tom Porter, Sr. CEA (520-740-6719), Pima County Regional Wastewater Reclamation Department

Subject: THE PLACE AT PRESIDIO TRAILS
Development Plan - 2nd submittal
DP12-0061

The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer collection lines for the above-referenced project. The following comments are offered for your use:

The Pima County Regional Wastewater Reclamation Department hereby approves the above referenced submittal of the development plan.

cc: Chad Amateau, PE Checked by:_________
Kristin Greene, PE, DLU Manager
DLU Project folder
07/17/2012 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

July 17, 2012

Chuck Martin
Rick Engineering Company
3945 E. Fort Lowell Road # 111
Tucson, Arizona 85711

Subject: DP12-0061 THE PLACE AT PRESIDIO TRAILS Development Package

Dear Chuck:

Your submittal for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and 2 sets of the DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE ROLLED

2 Rolled Copies of Revised Development Package (PDSD2)

1 CD of all Plans and Documents (PDSD)

Should you have any questions, please call me at 837-4893.

Sincerely,




John Williams
Planning Technician

All comments for this case are available on our website at http://www.tucsonaz.gov/dsd/

Via email: CMARTIN@RICKENGINEERING.COM

Final Status

Task End Date Reviewer's Name Type of Review Description
07/26/2012 CINDY AGUILAR OUT TO CUSTOMER Completed