Permit Number: DP12-0010
Parcel: 13323193C

Address:
730 N KOLB RD

Review Status: Completed

Review Details: RESUB - SITE and/or GRADING

Permit Number - DP12-0010
Review Name: RESUB - SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/14/2012 MARTIN BROWN FIRE REVIEW Approv-Cond Two exits are required from patio area. Exiting back into building shall not be designed. No roof covering is allowed over patio area without the installation of an approved automatic fire sprinkler system. Exiting shall comply with Chapter 10 of the 2006 IFC. Fire Inspector to verify at Fire Final.
05/15/2012 ANDREW CONNOR LANDSCAPE REVIEW Approved Ensure that all zoning comments and concerns are addressed prior to Landscape approval.
05/15/2012 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Guadalarjara Grill - Outdoor Patio Expansion
Development Package (2nd Review)
DP12-0010

TRANSMITTAL DATE: May 15, 2012

DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

The following comments are based on Development Standard 2-01.0:

1. This comment was not addressed. D.S. 2-01.3.7.A.9.b Provide a Building Coverage calculation on the plan. See PAD 3, Section 1 Development Area 1.b(3) .

2. This comment was not fully addressed. Per Development Standard 2-01.3.9.H.5.a "Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used)". That said the ratios used for the vehicle parking space calculation were not provided. The vehicle parking space calculation for this project should look something like;
GATEWAY 12PLEX THEATER - 2664 SEATS / 5 = 533 REQUIRED
COFFEE HOUSE - 3,190 S, F, / 100 = 32 REQUIRED
GUADALAJARA GRILL - 6,691 S. F. / 100 = 67 REQUIRED
TOTAL REQUIRED = 632
TOTAL PROVIDED = 679
D.S. 2-01.3.9.H.5.a Provide a vehicle parking space calculations on the plan. This calculation should include the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. This calculation shall include the entire site, i.e. parcels 133-23-193B, 133-23-193C & 133-23-194A. It appears that this site was not built per approved plan and that fewer vehicle parking spaces were provided than what was shown on the plan, ensure that the vehicle parking space calculation reflects this issue. Based on the vehicle parking space calculation shown on the building plans a Board of Adjustment for Variance maybe required

3. Based on the last approved development plans, Theater = 599, Friends Café = 32 and Tony Roma's = 52, the total number of vehicle parking spaces provided is 683. Your plan shows 692. Also based on the approved plan for Tony Roma's there are 28 vehicle parking spaces shown along the west side of the site, 32 shown north of the existing building. Your plan shows 27 vehicle parking spaces shown along the west side of the site, 29 shown north of the existing building for a difference of four (4) spaces. With that said the provided number for the entire site should be 679.


4. D.S. 2-01.3.9.H.5.d The bicycle parking calculation is not correct. The calculation for the theater should match what is shown on the approved development plan, see attached. For the Guadalajara Grill the calculation is based on Short and Long Term bicycle parking. For this project the calculation should be "Short-Term Required = 3, Short-Term Provided = 4, Long-Term Required 2, Long-Term Provided 2.

5. D.S. 2-01.3.9.H.5.d Provide a detail for the proposed Long-Term bicycle parking that shows that the requirements of LUC Sections 3.3.9.2 & 3.3.9.4 are met.

6. Once the above comments are addressed Zoning is willing to provide an over-the-counter review. Call or email to schedule an appointment for this over-the-counter review.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com

Sshield1 on DS1/planning/New Development Package/ DP12-0010

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/18/2012 GERARDO BONILLA APPROVAL SHELF Completed
05/18/2012 GERARDO BONILLA OUT TO CUSTOMER Completed
05/18/2012 GERARDO BONILLA REJECT SHELF Completed