Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP12-0005
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/25/2012 | CAGUILA1 | START | PLANS SUBMITTED | Completed | |
| 07/30/2012 | PGEHLEN1 | ENV SVCS | REVIEW | Approved | This project is approved for solid waste and recycle service. Jeff Drumm, P.E. Environmental Manager City of Tucson Environmental Services 520-837-3713 |
| 08/15/2012 | TERRY STEVENS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: DP12-0005 A-Family Discount Storage Development Package TRANSMITTAL: 08/22/12 DUE DATE: 08/22/12 COMMENTS: 1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is 01/10/2013. 2. DS 2-01.3.3 The rezoning case number indicated in the lower right corner of all sheets (C9-10-01) is the wrong case number, the correct rezoning case number is C9-09-04. Revise all sheets. This project is required to submit for and obtain approval of a special application for a wash overlay. Once completed, place the case number near the lower right corner of all sheets and provide a note indicating case umber, date of approval, what the special application was for and any conditions of approval. 3. DS 2-01.3.9.I Clearly indicate the area of right of way dedication required by the conditions of rezoning. On sheet 2 of 14. Clearly indicate the property lines with distances and bearings as they will be after the dedication. On sheet 2 of 14. Provide recording sequence number for the dedication of right of way. On sheet 2 of 14 4. DS 22-01.3.9.L Clearly indicate the recording information of the required easement per rezoning condition #5. 5. DS 2-01.3.9.U Provide a separate letter clearly indicating how each of the conditions of rezoning have been met. Condition of rezoning #17 requires an 8' wall along the south and east borders of the property. The elevations provided on sheet 14 of 14 indicate a 6'-8" wall. Clarify. The elevations provided do not appear to indicate the structures which are being used as part of the walls. Clarify. Clearly indicate the location and height of all walls and fences on the development plan. Revise keynote #20 on sheet 2 of 14 to reflect the required 8' wall. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 TLS C:\planning\cdrc\developmentplan\DP12-0005-2dp.doc |
| 08/17/2012 | KBROUIL1 | COT NON-DSD | FIRE | Approved | |
| 08/17/2012 | RONALD BROWN | ZONING HC | REVIEW | Denied | SHEETS 2, 3 AND 4: In reference to the accessible ramp shown on the site plans and detail 7/4: 1. The sidewalk is flush at the accessible parking aisle for access to the accessible route. The ramp in question is at the end of this flush sidewalk and has a slope of 2% according to the slope grades shown and is therefore not a ramp and does not have to met any accessible codes. Please delete all references to accessible ramps. |
| 08/23/2012 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 2ND FL TUCSON, AZ 85701-1207 AUDREY FARENGA ADDRESSING REVIEW PH #: 740-6800 FAX #: 623-5411 TO: CITY PLANNING FROM: AUDREY FARENGA, ADDRESSING REVIEW SUBJECT: DP12-0005 A-FAMILY DISCOUNT STORAGE/REVISED DEVELOPMENT PLAN DATE: August 23, 2012 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. 1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar or bond paper of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. |
| 08/24/2012 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Note the height and materials of any proposed walls (or fences) on the development plan. Ensure that information on the landscape plan matches. DS 2-05.2.4.X 2) Dedicate a 50' wide trail access easement along the Rodeo Wash per rezoning condition. 3) Revise the DP, LP, and the details on sheet 14 to coordinate. 4) Sheet 6 appears to include notes and inquiries regarding the conditions of rezoning. Address as necessary. 5) Revise the Native Plant Inventory to include all of the plants shown on the aerial photo. LUC 3.8. 6)Revise the plan (sheet 1) to reference the WASH overlay zone and add a note stating that the plat is designed to meet the overlay zone criteria and note the case file number, date of approval, and any conditions of approval. DS 2-03.2.2.B.7 7) The project is subject to the provisions of the Watercourse, Amenities, Safety, and Habitat Ordinance, TCC 29-16. A separate Overlay application and review is required. |
| 08/28/2012 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Patricia Gehlen DATE: August 28, 2012 CDRC/Zoning Manager SUBJECT: A-Family Discount, 2000 E. Drexel Rd Development Package D12-0005 (First Review) T15S, R14E, Section 08 RESUBMITTAL REQUIRED: Development Package. The Development Package (DP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Development Package: 1. Please include a response letter to the comments along with the corrected copies of the DP. 2. There appears to be some discrepancy with the R/W width, SVT's, sidewalk etc. for Drexel Road between the City of Tucson internal depts. (PDSD and Transportation) and you the consultant. Per our correspondence thru email, a meeting to discuss the R/W and Rodeo Wash issues was tentatively set for August 30, 2012. I am confidant that we will be able to solve these issues in order to obtain the Dev.Pkg. approval upon the next submittal. Drainage Report: 1. Please include a response letter to the comments along with the corrected copies of the DR. 2. A portion of the pervious comments will be discussed in the meeting mentioned above. If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson - Planning and Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/2000 E. Drexel Rd cdrc_Dev_Pkg 2 |
| 08/28/2012 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | This review has been completed. Resubmittal is required. |
| 08/28/2012 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | Jeff Stanley, Per our meeting the following subjects were discussed and will need to be addressed prior to the re-submittal: 1. The alignment and geography for Drexrel Rd. (per TDOT). 2. Verify the existance of an easement for maint. purposes for the Rodeo Wash or create a flowage easement. A maint. agreement must be included also. Thanks, Paul M. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/31/2013 | CPIERCE1 | OUT TO CUSTOMER | Completed |