Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: D11-0037
Parcel: 136100930

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D11-0037
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/10/2011 JWILLIA4 START PLANS SUBMITTED Completed
11/15/2011 LOREN MAKUS ENGINEERING REVIEW Approved November 15, 2011

The Engineering Division recommends approval of the Development Plan.

Loren Makus, EIT
Senior Engineering Associate
11/16/2011 RONALD BROWN H/C SITE REVIEW Approved
11/16/2011 JWILLIA4 PIMA COUNTY WASTEWATER Denied PIMA COUNTY
REGIONAL WASTEWATER RECLAMATION DEPARTMENT
201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 740-6500
DIRECTOR FAX: (520) 620-0135


November 16, 2011

To: DAN SKEEHAN, P.E.
KIMLEY-HORN AND ASSOCIATES, INC

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department


____________________________________________
From: Tom Porter, Sr. CEA (520-740-6719), Pima County Regional Wastewater Reclamation Department

Subject: WALMART TUCSON (GOLF LINKS), AZ STORE #5799-00
Dev. Plan – 2nd submittal
D11-0037

The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer collection lines for the above-referenced project. The following comments are offered for your use:

1. Sheet 11: Call out the reference number for the sewer line to be built by others which you are proposing to connect to. Ref. A

2. Sheet 11: The public sewer easement shown on plan must be recorded before development plan approval Ref. A. 2nd Request.

This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the third(3rd) submittal. A check for the review fee of this submittal in the amount of $39.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.


cc: Chad Amateau, PE Checked by:_________
Kristin Greene, PE, DLU Manager
DLU Project folder

Ref. A. Development Plan Checklist Requirements – Chapter 18.71 of the Pima County Code - Section J
http://www.pimaxpress.com/SubDivision/Documents/2006/DP_Requirements2Aug04.pdf

Ref. C - Arizona Administrative Code, Title 18, Chapters 5 & 9 (R18-5-205)
http://www.azsos.gov/public_services/Title_18/18-05.htm
and (R-18-9-E301)
http://www.azsos.gov/public_services/Title_18/18-09.htm

Ref. D - PCRWRD Procedures, Preliminary Sewer Layout Requirements, 1984 (revised April 1988)
http://www.pima.gov/wwm/eng/stddet/pdf/procedures.pdf

Ref. E - PCRWRD Design Standards for Public Sewerage Facilities, 1983 (revised April 1988)
http://www.pima.gov/wwm/eng/stddet/pdf/design_standards.pdf

Ref. F - City of Tucson/Pima County Standard Details
http://www.pima.gov/wwm/eng/stddet/pdf/all_det.pdf

Ref. G - Pima County Code of Ordinances, Title 13 - Public Services, Division II - Sewers
http://library.municode.com/index.aspx?clientID=16119&stateID=3&statename=Arizona

Ref. H - City of Tucson/Pima County Standard Specifications for Public Improvements, 2003 Edition
http://dot.pima.gov/transeng/stdspecsdet/standardspecs2003.pdf

Ref. I - PCRWRD Engineering Directives
http://www.pima.gov/wwm/eng/directives/
11/17/2011 JOSE ORTIZ COT NON-DSD TRAFFIC Approved Resubmittal - Approved by Traffic Engineering TDOT
11/21/2011 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: D11-0037
Walmart - Store No. 5799-00
Development Plan

TRANSMITTAL DATE: November 21, 2011

DUE DATE: November 29, 2011

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The Zoning Review Section approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements.

2. Revise the following two (2) items:

A. On sheet C4.3, Paving Notes, note 11, add the separation distance or refer to ADA detail on sheet C10.8.

B. The short term bicycle detail on C10.8 does not match the plan view drawing. The plan view drawing appears to have separate Short term "LOOP" or inverted "U" type facilities and the detail drawing depicts a facility with connected racks. Revise the detail drawing to match the plan view drawing.

3. Zoning also approves the grading plan as it relates to the Zoning review purview of the grading plan. If the grading requires additional changes due to additional review comments, zoning requests that the grading plan be submitted for zoning review to ensure compliance with the approved development plan.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

DGR C:\planning\cdrc\developmentplan\D11-0037dp2.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan
11/29/2011 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond 1) Revise Grading and Drainage Note 19 on sheet C5.3 to refer to a City of Tucson approved detail or provide a new detail for review.

2) The previous response letter indicates that a detail for a drainage wall opening was provided on sheet C10.1. None was detected. Revise as necessary.
11/30/2011 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

November 30, 2011

Dan Skeehan
Wal-Mart Stores, Inc.
2210 E. Fort Lowell Rd. #200
Tucson, Arizona 85719

Subject: D11-0037 WAL-MART STORE #5799 Development Plan

Dear Dan:

Your submittal of October 13, 2011 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 4 DETAILED cover letters explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

4 Copies Revised Development Plan (Wastewater, Zoning, Landscape, PDSD)

3 Copies Revised Landscape Plan (Zoning, Landscape, PDSD)

1 Check Made out to “Pima County Treasurer” for $39.00 (Wastewater)


Should you have any questions, please call me at 837-4893.


Sincerely,




John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via Email: dan.skeehan@kimley-horn.com