Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D11-0035
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/08/2011 | CPIERCE1 | START | PLANS SUBMITTED | Completed | |
| 12/09/2011 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 12/12/2011 | JASON GREEN | ENGINEERING | REVIEW | Approv-Cond | DATE: December 12, 2011 SUBJECT: The Retreat Development Plan Package- 3rd Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 920 E 22nd Street, T14S R14E Sec19 Ward 5 REVIEWERS: Jason Green, CFM ACTIVITY: D11-0035 SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the proposed Development Plan Package, Drainage Report (Rick Engineering Co, 11OCT11), Geotechnical Engineering Report (Terracon 02SEP11), Stormwater Pollution Prevention Plan (Rick Engineering Co, 07OCT11). Engineering Division recommends conditional approval of the Development Plan Package at this time. The following items need to be addressed prior to final CDRC approval: DRAINAGE REPORT: 1) Completed. 2) Completed. DEVELOPMENT PLAN: 3) Completed. 4) Completed. 5) Acknowledged. 6) Completed. 7) Completed. 8) Completed. 9) Completed. 10) Completed. 11) Completed. 12) Acknowledged. 13) Completed. 14) Completed. 15) Completed. 16) D Completed. 17) Omitted. 18) Completed. 19) Completed. 20) Restated: DS Sec.2-01.3.9.N.1: Revise the development plan document for all access areas of the proposed basin access ramps to clearly show that the removable bollards (SD #107) adjacent to the refuse enclosure access area are constructed between the depressed curb and sidewalk area. The post barricades can not be located on the other side of the sidewalk for pedestrian safety and to provide a vehicular separation between the parking space and pedestrian access route. 21) Acknowledged. 22) Completed. 23) Completed. 24) Completed. 25) Completed. 26) Completed. 27) Completed. 28) Restated: DS Sec.2-01.3.9.N.3: Revise Sheet 19 and the call out associated with the proposed ADOT detail. Per Sheet 19 the call out references Zero (0) feet for the headwall length. Clarify the dimension on the call out prior to final approval. 29) Completed. 30) Completed. 31) Completed. 32) Completed. 33) Completed. 34) Completed s. 35) Completed. GEOTECHNICAL REPORT: 36) Completed. GENERAL COMMENTS: Please provide a revised Development Plan Package that addresses the 2 comments provided above for final CDRC approval. For any questions or to schedule meetings call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Planning & Development Services Department |
| 12/15/2011 | RONALD BROWN | H/C SITE | REVIEW | Approved | |
| 12/19/2011 | JWILLIA4 | UTILITIES | TUCSON ELECTRIC POWER | Approv-Cond | SUBJECT: THE RETREAT D11-0035 Tucson Electric Power Co. (TEP) conditionally approves the Development Package submitted for review December 8, 2011. TEP requests that the easement highlighted on the attachment be corrected. Note No. 33, on Sheet 6 incorrectly identifies a TEP easement. The correct Docket is 5931 at Page 959. A copy of the Alta survey has been requested from Rick Engineering and is still required for TEP's review prior to releasing any easements. Easements will not be released until existing facilities have been removed. Any existing underground and overhead facilities that must be removed or relocated due to the project will be billable to the developer. The area Designer is Mike Kaiser - he may be reached at 520-918-8244. If you have any questions, please contact me at 917-8744. Thank you, Mary Burke Associate Right of Way Agent Tucson Electric Power Company 88 E. Broadway Blvd. 85701 Mail Stop HQW603 Tucson, AZ 85702 520-917-8744 Office 520-401-9895 Cell mburke@tep.com |
| 12/19/2011 | JWILLIA4 | ENV SVCS | REVIEW | Approved | Date Case Number Project Address December 19, 2011 D11-0035 THE RETREAT DEVELOPMENT PLAN Comments: The proposed DEVELOPMENT PLAN for Case No. D11-0035, THE RETREAT Is acceptable and approved for Environmental Services Solid Waste Service and Recycle Disposal Standard 6-01. Environmental Services Department Development Plan Review Reviewer: Tony Teran Office Phone (520) 837-3706 E-mail: Tony.Teran @tucsonaz.gov |
| 12/20/2011 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES December 20, 2011 Tri Miller Rick Engineering Company, Inc. 3945 E. Fort Lowell Rd. #111 Tucson, Arizona 85712 Subject: D11-0035 THE RETREAT Development Package Dear Tri: The above referenced Development Package has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made, please submit the following documents for sign-off. 1 Rolled COMPLETE SET of the Development Package. Please include applicable sheets from any other concurrent reviews. 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan (if applicable). Additional print copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City’s contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your plans to the CDRC office for sign-off approval. Plans will not be signed and released until the CDRC office has been notified by PC Addressing that all fees for this plan have been paid. The CDRC office will need this confirmation in writing. A Development Package remains valid for a period of three (3) years from the date of approval. This Development Package will expire on 12/20/2014 per LUC 5.3.8.2.B. PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. Should you have any questions, please call me at (520) 837-4893. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.tucsonaz.gov/dsd/ Via fax: (520) 322-6956 |