Permit Number: D11-0032
Parcel: 115202610

Review Status: Completed

Review Details: REVISION - DEV PLAN

Permit Number - D11-0032
Review Name: REVISION - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/15/2012 GBONILL1 START PLANS SUBMITTED Completed
05/15/2012 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
05/23/2012 RONALD BROWN HC SITE REVIEW Denied ORIGINIAL COMMENTS OF 10/25/11 NEVER ADDRESSED. SEE BELOW:

SHEET C02
1. Detail F:
a. Provide grade slopes in all accessible parking spaces and aisles as per ICC~ANSI 117.1, Sections 502.5
b. Provide "Van Accessible" parking spaces as required by Section 1106.5 and ANSI 117.1, Section 502.2.
c. Detectable Warning strips are not required at accessible parking aisles unles thay are a part of a marked crossing.
2. Detail G:
a. Change the 6'-0" dimension to 7'-0" as per COT DOT requirements.
b. Provide "Van Accessible" signage.
SHEET C2.0
3. Note 11 is applicable for ramps in the public right of way. This is not compliant for accessibility within private property boundaries. Please detail and reference ICC~ANSI 117.1, Sections 405 and 406 for sidewalk and curb ramps.
4. Please show the ramp access from all the accessible parking ailses to the accessible route.
5. Just North of the two dumpsters there is a curb ramp with a detectable warning at the end of the sidewalk accessible route that leads to no where. Please delete this ramp and provide a 6" high curb.
6. Note 11 identifies two opposing ramps with detectable warnings. Please provide a marked crossing between these two ramps.
a. If this is intended as a passenger drop off zone, please comply with Section 1106.7 and ICC~ANSI 117.1, Section 503.
7. Please add a marked crossing at the PAAL crossing located in The South West corner of the site.
8. Please provide a large scale detail of all the different types of ramps including dimensions, slopes and landings as required.
9. Detectable Warnings are not required at the sidewalk ramps shown in front of the most Northerly accessible parking spaces.
SHEET 3.0 AND 3.1
10. Insure that the slopes of all accessible routes comply with ICC~ANSI 117.1, Section 403.3
11. Please provide a written response to each comment.
END OF REVIEW

Final Status

Task End Date Reviewer's Name Type of Review Description
07/05/2012 CPIERCE1 OUT TO CUSTOMER Completed