Permit Number: D11-0027
Parcel: 12217283C

Review Status: Completed

Review Details: DEVELOPMENT PLAN

Permit Number - D11-0027
Review Name: DEVELOPMENT PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/25/2011 JWILLIA4 START PLANS SUBMITTED Completed
08/26/2011 LEERAY HANLY ADA REVIEW Approved
08/26/2011 DAVID MANN COT NON-DSD FIRE Approved
08/26/2011 LEERAY HANLY ZONING HC REVIEW Approved
09/08/2011 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved >>> "Monica M. Soto" <MSoto@azdot.gov> 09/02/2011 8:23 AM >>>
Regional Traffic Engineering has no comment on this submittal and recommends approval of the development.
It will have no impact on any existing ADOT facilities.
Thank you.


Monica M. Soto

Government Intern
Arizona Department of Transportation
Tucson District
09/09/2011 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR#241049 September 9, 2011

PRE
Attn: Stephen Sanchez
P.O. Box 36985
Tucson, Arizona 85705

Dear Mr. Sanchez:

SUBJECT: Loft Cinema New Parking Lot
D11-0027

Tucson Electric Power Company has reviewed and approved the development plan submitted August 25, 2011. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans.

If easements are required, they will be secured by separate instrument. Your final plans should be sent to:
Tucson Electric Power Company
Attn: Mr. ricahrd Harrington
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8726

Should you have any technical questions, please call the area Designer Mike Kaiser at (520) 918-8244.

Sincerely,


Elizabeth Miranda
Office Support Specialist
Design/Build
lm
Enclosures
cc: DSD_CDRC@tucsonaz.gov, City of Tucson (email)
M. Kaiser, Tucson Electric Power
09/09/2011 FRODRIG2 ENV SVCS REVIEW Approved Date Case Number Project Address
September 9, 2011 D11-0029 LOFT CINEMA NEW PARKING LOT
DEVELOPMENT PLAN

Comments:
The proposed new parking lot development plan Case No. D11-0027, for the
LOFT CINEMA. Meets the minimum requirements for Environmental Services
Solid Waste and Recycle materials, and is hereby Approved.



Environmental Services Department
Development Plan Review
Reviewer: Tony Teran
Office Phone (520) 837-3706
E-mail: Tony.Teran @tucsonaz.gov
09/13/2011 JOSE ORTIZ COT NON-DSD TRAFFIC Approved Approved

Review conducted by Zelin Canchola
09/14/2011 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Denied AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: D11-0027 THE LOFT CINEMA NEW PARKING LOT/DEVELOPMENT PLAN
DATE: September 14, 2011



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

On the Location Map change Camilla Av to Boulevard and change 3/11 to 3/111.
Spell out Boulevard of Camilla Blvd on all applicable sheets.
09/16/2011 LOREN MAKUS ENGINEERING REVIEW Denied September 12, 2011
D11-0027
Parking for The Loft Cinema

The Engineering Division doesn't recommend approval at this time. The following comments must be addressed:

Drainage report
1. The retention volume is not computed correctly. Provide the calculation using both the 5-year rainfall depth and 5-year runoff coefficients. Equation 3.3 in the Detention/Retention manual provides an estimated value for the required retention volume. The values for the runoff coefficients in the equation must be determined by the City of Tucson hydrology procedures. If you want to use the estimated results only, please provide justification for the change. DS 10-01.3.2

2. Provide information in the drainage report showing the design of the basins and demonstrate how the stated volumes are provided. DS10-01.V.6

Site Plan/Grading Plan

1. Revise the label in the water harvesting area in the center of the parking area. The note indicates that the water harvesting area is to be 6 inches deep. The top and bottom grades indicate the basin is a foot deep. The rezoning conditions require the basin to be a minimum of 12 inches deep.

2. Clearly label the header proposed for the east boundary of the parking area.

3. The water harvesting areas along the north and west project boundaries have no apparent inlet for water runoff. Provide curb openings or headers to direct water to these water harvesting areas. Pavement grades may need to be adjusted to direct runoff to the basins.

4. Since water harvesting is being used to meet the retention requirements, show how the retention volume is attained within the proposed water harvesting areas. Consider using micro-berms across the water harvesting area along the north boundary to increase the effective volume.
09/23/2011 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Denied PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D11-0027 Loft - Cinema NewParkingLot

() Tentative Plat
(X) Development Plan
(X) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
(X) Other - Elevations

CROSS REFERENCE: C9-10-02

NEIGHBORHOOD PLAN: Grant-Alvernon Area Plan

GATEWAY/SCENIC ROUTE: NO

COMMENTS DUE BY: September 26, 2011

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an FLD, No Comment
() Proposal Complies with Rezoning Conditions
() RCP Proposal Complies With Plan Policies
(X) Resubmittal Required - See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:

(X) Resubmittal Required:
() Tentative Plat
(X) Development Plan
(x) Landscape Plan
() Other

REVIEWER: msp 791-5505 DATE: 9/21/2011

Community Planning Section
D11-0027, Loft -Cinema-New Parking Lot
September 21, 2011

This development plan is subject to rezoning case C9-10-02, as approved by Mayor and Council under Ordinance 10838. Staff offers the following comments:

1. Please revise development plan, sheet 1 to include rezoning case C9-10-02. Include all of the rezoning conditions (verbatim), as approved by Mayor and Council on September 14, 2010, under Ordinance 10838.
09/23/2011 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: D11-0027
Loft Cinema New Parking Lot
Development Package

TRANSMITTAL: 09/23/2011

DUE DATE: 09/23/2011

COMMENTS:

1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is 08/24/2012.

2. DS 2-01.2.5 A three (3) inch by five (5) inch space shall be reserved in the lower right quadrant of each sheet for an approval stamp.

3. DS 2-01.3.2.D Place outside of the title block the administrative address of this project.

4. DS 2-01.3.3 Remove permit number T11CMXXXXX and place development plan number D11-0027 near the lower right corner of all sheets.

5. DS 2-01.3.7.A.1 Revise general note #1 to read as follows: Existing zoning is R-3, Proposed zoning is P.

6. DS 2-01.3.7.A.4 Revise general note #2 in regards to the proposed use as follows: Parking "40", subject to: Sec. 3.5.4.12

7. DS 2-01.3.9.H.5.a The total of 82 parking spaces will require 3 handicap parking spaces. See IBC 1106.1 and Ron Brown's comments.

Provide wheel stop curbs in the vehicle parking spaces along the north side of the project. Required to prevent overhanging into the required landscape border.

On detail 5 on sheet 5 of 9, provide a dimension from the front of the parking space to the front of the wheel stop, minimum 2'-6".

8. DS 2-01.3.9.H.5.d Bicycle parking is not required for this project but if being provided they must meet the criteria of LUC Sec. 3.3.9 for design as well as pedestrian circulation to the bicycle parking spaces. If not provided remove from calculations.

9. DS 2-01.3.9.H.5.c Loading zones are not required for this project, remove general note #6. (wrong code section anyway)

10. DS 2-01.3.9.Q The pedestrian circulation path indicated from the handicap parking spaces cannot be located within a PAAL reducing the width to less than the required 24'.

The pedestrian circulation path must be physically separated from the vehicle use area. See DS 2-08.4.1.

The pedestrian circulation path (sidewalk ) is to be constructed of concrete. See DS 2-08.5.1.C.

Clearly indicate the accessible route from the handicap parking spaces to the building. A separate sheet may be required.

FYI: If the required 3 handicap parking spaces were located adjacent to the existing building or in close proximity and provided with an accessible pedestrian circulation path to the building the long pedestrian circulation path indicated would not be required. If this is selected provide a plan clearly indicating the location of the handicap parking spaces with access to the building

11. List the condition of rezoning on the plan and provide a separate letter clearly indicating how each of the conditions have been met.

12. Remove general note numbers 12 and 14 as they do not apply.


If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961




TLS C:\planning\cdrc\developmentplan\D11-0027dp.doc





09/23/2011

Development Services Department
Zoning Review Section

Terry Stevens
Lead Planner

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the grading plan was in compliance with the approved development plan. Please submit two copies of the approved and stamped development, landscape, and NPPO plans with the next grading plan submittal.

3. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved site/development plan. Additional comments may be forthcoming.
09/26/2011 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond 1) Revise the plans to clarify complaince with the standards for required screen walls along the north and east property boundaries. Define any line work signifying new cmu walls, clearly show all new or revised walls on the property, clarify that walls run the full length of the property boundaries adjacent to residentially zoned property.
09/26/2011 JANE DUARTE COT NON-DSD PARKS & RECREATION Approved
09/27/2011 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Denied
09/27/2011 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
09/27/2011 PGEHLEN1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Passed
09/27/2011 ED ABRIGO PIMA COUNTY ASSESSOR Passed
09/27/2011 PGEHLEN1 COT NON-DSD REAL ESTATE Passed
09/27/2011 TIM ROWE PIMA COUNTY WASTEWATER Passed See waiver in sire.