Permit Number: D11-0025
Parcel: 113100990

Address:
2611 N WARREN AV

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D11-0025
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/22/2011 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved >>> Tom Martinez <TMartinez@azdot.gov> 11/22/2011 9:26 AM >>>

Regional traffic Engineering has no comments on this submittal and recommends approval of the Exception. Thank you.
11/22/2011 DAVID MANN COT NON-DSD FIRE Approved
11/22/2011 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/22/2011 TOM FISHER COT NON-DSD TDOT Approved >>> Zelin Canchola 11/22/2011 10:16 AM >>>
Catalina Care Center D11-0025 - Approved by TDOT Traffic Engineering.
12/07/2011 JWILLIA4 PIMA COUNTY WASTEWATER Denied PIMA COUNTY
REGIONAL WASTEWATER RECLAMATION DEPARTMENT
201 NORTH STONE AVENUE
TUCSON, ARIZONA 85701-1207
JACKSON JENKINS PH: (520) 740-6500
DIRECTOR FAX: (520) 620-0135


December 6, 2011

To: MERIDIAN SURVEYING & DEVELOPMENT, INC

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department


____________________________________________
From: Tom Porter, Sr. CEA (520-740-6719), Pima County Regional Wastewater Reclamation Department

Subject: CATALINA CARE CENTER
Dev. Plan – 1st submittal
D11-0025

The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer collection lines for the above-referenced project. The following comments are offered for your use:

1. Sheet 1: Obtain a letter from the PCRWRD’s Development Liaison Unit, written within the past year, stating that treatment and conveyance system capacity for the project is available in the downstream public sewerage system and provide a copy of that letter to this office. The required form to request such a letter may be found at:

http://www.pima.gov/wwm/developer.htm#permits

The development plan for this project cannot be approved until a copy of this letter has been received by this office. Ref. A.

2. Sheet 1: Include the following General and Permitting Notes (Ref. A):

THIS PROJECT WILL HAVE ______ EXISTING AND______ PROPOSED WASTEWATER FIXTURE UNIT EQUIVALENTS PER TABLE 13.20.045(E)(1) IN PIMA COUNTY CODE 13.20.045(E).

And fill in the blanks with the appropriate values.

ANY RELOCATION, MODIFICATION, ETC., OF THE EXISTING UTILITIES AND/OR PUBLIC IMPROVEMENTS REQUIRED BY THIS DEVELOPMENT WILL BE AT NO EXPENSE TO THE PUBLIC.

A PROJECT CONSTRUCTION PERMIT MUST BE SECURED FROM PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT BEFORE BEGINNING ANY WORK ON THIS PROJECT.

3. Sheet 1: If no new sewer is proposed then include the following General Note(Ref. A).:

THE ON-SITE SEWERS ARE EXISTING AND PRIVATE. NO NEW SEWERS ARE PROPOSED.

4. Sheet 5: The sewer has not been shown on this plan. Refer to Pima County Development Services “Development Plan Review, Checklist Requirements” section J. WASTEWATER, for submittal requirements. The checklist is available at;

http://www.pimaxpress.com/SubDivision/Documents/DevPlanReq.pdf

This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the second(2nd) submittal. A check for the review fee of this submittal in the amount of $100.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.


cc: Chad Amateau, PE Checked by:_________
Kristin Greene, PE, DLU Manager
DLU Project folder

Ref. A. Development Plan Checklist Requirements – Chapter 18.71 of the Pima County Code - Section J
http://www.pimaxpress.com/SubDivision/Documents/2006/DP_Requirements2Aug04.pdf

Ref. C - Arizona Administrative Code, Title 18, Chapters 5 & 9 (R18-5-205)
http://www.azsos.gov/public_services/Title_18/18-05.htm
and (R-18-9-E301)
http://www.azsos.gov/public_services/Title_18/18-09.htm

Ref. D - PCRWRD Procedures, Preliminary Sewer Layout Requirements, 1984 (revised April 1988)
http://www.pima.gov/wwm/eng/stddet/pdf/procedures.pdf

Ref. E - PCRWRD Design Standards for Public Sewerage Facilities, 1983 (revised April 1988)
http://www.pima.gov/wwm/eng/stddet/pdf/design_standards.pdf

Ref. F - City of Tucson/Pima County Standard Details
http://www.pima.gov/wwm/eng/stddet/pdf/all_det.pdf

Ref. G - Pima County Code of Ordinances, Title 13 - Public Services, Division II - Sewers
http://library.municode.com/index.aspx?clientID=16119&stateID=3&statename=Arizona

Ref. H - City of Tucson/Pima County Standard Specifications for Public Improvements, 2003 Edition
http://dot.pima.gov/transeng/stdspecsdet/standardspecs2003.pdf

Ref. I - PCRWRD Engineering Directives
http://www.pima.gov/wwm/eng/directives/
12/08/2011 JWILLIA4 ENV SVCS REVIEW Denied Date Case Number Project Address
December 7, 2011 D11-0025 Catalina Care Center
DEVELOPMENT PLAN

Comments: Denied,
The proposed Development Plan for the Catalina Care Center, Case No.D11-0025.
Located at 2611 North Warren Avenue, Dose not meets the minimum
requirements for the Environmental Services, Solid Waste and Recycle Disposal
Standard 6-01.0

1. All containers shown on the Development Plan must be labeled for the intended us
being Solid Waste or Recycle materials

2. The detail of the container enclosures must clearly show, the minimum inside
dimension between the bollards shall be a 10’- 0”. As shown on the Solid Waste
Standards.

3. The gates for the container enclosures must be shown, installed and
mounted on a separate post at the end on the CMU screen wall as show on Solid
Waste Standards.

4. The proposed location for the Solid Waste and Recycle container enclosures shown
on the plan will not allow adequate space for services vehicles to maneuver and
services the containers. It will be necessary to relocate the container enclosures to
an alternative location on site.


Environmental Services Department
Development Plan Review
Reviewer: Tony Teran
Office Phone (520) 837-3706
E-mail: Tony.Teran @tucsonaz.gov
12/08/2011 RONALD BROWN H/C SITE REVIEW Denied SHEET
1. More than likely, Zoning will require several pedestrian accesses to all the public street right of ways. If so, all the required pedestrian accesses are to be accessible routes. Reference Zoning comments.
2. For any accessible route crossing a PAAL, please provide a marked crossing complete with detectable warning strips per ICC/ANSI 117.1, Section 405.12 and 405.14.
SHEET 2 OF 5
3. Insure that all slopes of all the accessible routes comply with ICC/ANSI 117.1, Section 403.3.
4. Insure that all slopes of the accessible parking spaces and aisles comply with ICC/ANSI 117.1, Section 502.5.
SHEET T1
5. Add a general note "D": The accessibility code used for this project is the 2006 IBC, Chapter 11 and ICC/ANSI 117.1, 2003 Edition.
SHEET A1
6. Ditto comments 1 and 2.
7, Reference the front entrance porte cochere and accessible parking to the Partial Site Plan detail on sheet A3.
8. At the SW corner of the building there appears to be a partially complete marked crossing. Please complete the detailing here and reference to a new large scale detail of this crossing showing all ramps, detectable warning strips, marked crossings and accessible routes in compliance with ICC/ANSI-117.1, Sections 405.12 and 405.13.
SHEET A3
9. Detail 3/A3:
a. Change the 4'-0" dimension to 7'-0"
b. Please add a "Van Accessible" sign.

END OF REVIEW
12/09/2011 STEVE SHIELDS ZONING REVIEW Denied TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Catalina Care Center - Expansion
Development Plan (2nd Review)
D11-0025

TRANSMITTAL DATE: December 9, 2011

DUE DATE: December 15, 2011


DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is July 28, 2012

2. Per LUC Section 2.3.5.3.S.3 Medical Service in a R-2 zone requires a Special Exception though a Zoning Examiner Full Notice Procedure, Sec. 23A-50 and 23A-53. The Special Exception must be approved prior to approval of this development plan. If the Special Exception is approved and there are any conditions the conditions must be listed on the development plan and you must show how each condition is met. Contact Michael Wyneken @837-4955 in regards to the Special Exception process.

3. This comment has not been completely addressed. Provide the Special Exception case number on the plan. D.S. 2-05.2.2.B.2 Provide the development plan number, D11-0025 and the Special Exception case number, in the lower right corner of the plan.

4. D.S. 2-05.2.2.B.3 Revise General Note A.4 to read "MEDICAL SERVICE - EXTENDED HEALTH CARE "19", SUBJECT TO: SEC. 3.5.4.8.B, SEC. 3.5.4.9.A, .B.1, .C, AND .D, AND APPROVAL THROUGH A ZONING EXAMINER FULL NOTICE PROCEDURE, SEC. 23A-50 AND 23A-53." NURSING HOME" is not a use listed in the LUC.

5. This comment has not been addressed. D.S. 2-05.2.4.A As the proposed site encompasses four (4) parcels a lot combination is required. Provide a copy of the approved Pima County Assessor's Combination Request form with your next submittal. Once approved remove all interior lot lines from the site plan.

6. This comment was not fully addressed. Along the north side of the proposed addition there are areas where building pop outs reduce the width of the sidewalk. Provide width dimension at these areas. D.S. 2-05.2.4.K Provide width dimensions for all sidewalks, existing and proposed, on the site plan.

7. This comment was not fully addressed. Provide a sidewalk on site to Copper Street. D.S. 2-05.2.4.K Per D.S. 2-08.4.1.A At least one (1) sidewalk will be provided to a project from each street on which the project has frontage. That said provide a sidewalk to both Copper and Cherry.

8. D.S. 2-05.2.4.Q Remove all references to Class 1 and Class 2 bicycle parking from the plans as Development Standard 2-09.0 is not applicable. See LUC Section 3.3.9 for bicycle parking design criteria. The dimension shown on the plan are not correct.

9. D.S. 2-05.2.4.Q The proposed "INVERTED "U"" called out for Class 1 - long term bicycle parking does not meet the requirements of LUC Section 3.3.9.4.

10. D.S. 2-05.2.4.U Indicate graphically, where possible, and by notes, in all other instances, compliance with conditions of the Special Exception. Additional comments may be forth coming based on the conditions.

11. Per LUC Section 2.3.5.3.A.3 the requirements of LUC Section 3.5.4.9.A.2 apply to this project. As this property does not meet this Section a Board of Adjustment for Variance is required.

12. There is reference to a Board of Adjustment for Variance in your response comments. If a Board of Adjustment for Variance has been applied for and approved provide the Board of Adjustment for Variance number, date of approval, what was approved and any conditions of approval on the plan. Also provide a copy of the Board of Adjustment for Variance letter with your next submittal. Additional comments may be forth coming based on the Board of Adjustment for Variance.

13. If applicable ensure all changes are made to the grading and landscape plans.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com

Sshield1 on DS1/planning/Development Plan/ D11-0025

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan
12/12/2011 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond 1) Submit any applicable common wall agreements. Note recording data on the development plan.

2) Revise the plans to include the tree symbols used in the eastern portion of the site.
12/14/2011 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 12/14/2011,


TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Catalina Care Center
D11-0025, T13S, R14E, SECTION 31

RECEIVED: Development Plan and Landscape Plan on November 16, 2011

The subject submittal has been reviewed and it can not be approved at this time. Address the following comments before review can continue. Prepare a detailed response that explains the revisions that were made and references the exact location in the drainage Statement and on the Development Plan where the revisions were made:

Drainage Statement:

1. Submit a drainage statement which addresses onsite and offsite runoff impact on the proposed improvements. The statement shall address the flood hazard area to the south and it impact on this development. It shall also address the site proposed drainage after the installation of the proposed building, how the court yard, which appears to be enclosed, is proposed to drain, especially in case of a major storm, the proposed facilities design calculations (e.g. sidewalk scuppers), etc. This requirement will be a condition of the special exception.

Development Plan:

1. This project has been submitted for a "Special Exception". The Development Plan can not be approved until the Special Exception process has been completed and the special exception has been granted and the special conditions have been complied with.
2. It is not clear why the submittal sheets have been numbered inconsistently (some sheets have only numbers, some have letters and numbers).Revise the sheet numbering to be more consistent.
3. It appears that if the submittal is prepared to comply with the requirements of Development Standard 2-05.0., the number of sheets will be reduced and the information will be presented in a more simplified way.
4. Complete the D11-0025 subdivision case number, on every sheet, as required by D.S. 2-05.2.2.B.2
5. All lettering and dimensions shall be the equivalent of twelve (0.12") point or greater in size (D.S. 2-05.2.1.C).
6. The contour intervals should be placed on each sheet, preferably in the upper right corner of the plan (D.S. 2-05.2.1.H).
7. Show, on the first sheet, the tie between one of the parcel corners to the basis of bearing (D.S. 2-05.2.3.A).
8. Provide the right of way width, recordation data, type and paving width, the dimensions of curbs, curb cuts and sidewalks, for all adjacent streets, as required by D.S. 2-05.2.3.C.
9. Provide, based on the findings of the drainage statement, floodplain information, including the location of the 100-year flood limits for all flows of 100-cfs or more with 100-year water surface elevations as required by D.S. 2-05.2.3.I.
10. Show, based on the recommendations of the drainage statement, the proposed drainage solutions, such as origin, direction, and destination of flow (including roof drainage) and method of collecting and containing flow (D.S. 2-05.2.4.H.2).
11. Provide the locations and types of drainage structures, as required by D.S. 2-05.2.4.H.3.
12. Based on the findings of the drainage statement, draw locations and indicate types of off-site runoff acceptance points and/or on-site discharge points (D.S. 2-05.2.4.H.7).
13. Show all applicable building setback lines, including setbacks from ponding water in the water harvesting areas. Setback recommendation shall be included in the geotechnical report (D.S. 2-05.2.4.I).
14. Provide the missing offsite sidewalks along Warren Avenue including any required wheelchair ramps with truncated domes (D.S. 2-05.2.4.L). This requirement will be a condition of the special exception.
15. Provide the location and size of all sidewalk scuppers including the ones associated with roof drainage (D.S. 2-05.2.4.H.3). Show all buildings roof drainage direction. This information shall be based on the drainage statement recommendation.
16. In order to ensure that the waterharvesting basins will not keep ponding water for more than 12 hours after a storm, the geotechnical report shall include a percolation test for all basins that are deeper than 6 inches. If percolation rates are poor, the basins shall be designed with 6 inch depths or less, or they shall be provided with other acceptable methods that can eliminate prolonged ponding times.
17. The sight visibility triangles appear to be drawn incorrectly. Refer to D.S.3-01.5. for sight visibility information and dimensions.
18. It appears that the location of the trash enclosure is inaccessible. Relocate the refuse enclosure to make it accessible (D.S. 2-05.2.4.T).
19. Indicate graphically, where possible, and by notes, in all other instances compliance with the special exception conditions (D.S. 2-05.2.4.U).
20. Keynote #9, on Sheet 2 of 5 of the Grading and Paving Plan, is described as "sidewalk scupper", but it shown as a curb opening near the Mitchell Street entrance. Revise as necessary.
21. It is not clear which Sheet 4 that is referenced in the Paving Notes on Sheet 2 of 5 of the Grading and Paving Plan. Revise as necessary.
22. Revise the Development Plan in accordance with the drainage report revisions.

Grading Plan and SWPPP:

Grading and SWPPP Plan submittal is premature at this point. Existing and proposed grades and preliminary grading information shall be shown on the Development Plan. Please be advised that if the proposed disturbed area is less than one acre, a SWPPP will not be required.


RESUBMITTAL REQUIRED: Revised Development Plan, Landscape Plan and Drainage Statement
12/15/2011 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D11-0025 CATALINA CARE CENTER

() Tentative Plat
(X) Development Plan
(X) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other - Elevations

CROSS REFERENCE: Special Exception SE-11-42 & Board of Adjustment

NEIGHBORHOOD PLAN: Cragin-Keeling Area Plan and the General Plan

GATEWAY/SCENIC ROUTE: NO

COMMENTS DUE BY: December 15, 2011

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Rezoning Conditions
() RCP Proposal Complies with Plan Policies
(X) See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(X) Resubmittal Required:
() Tentative Plat
(X) Development Plan
(X) Landscape Plan
() Other

REVIEWER:msp 837-6971 DATE: 12/15/2011
Department of Planning and Development Services
Community Planning Comments
D11-0025 - Catalina Care Center
December 15, 2011

The site is subject to Special Exception case SE-11-42. Staff offers the following comments:

1. Please revise development plan D11-0025, and list verbatim all conditions of Special Exception case SE-11-42, as approved by Mayor and Council on ____________.

2. Please revise development plan D11-0025, to show location of refuge containers at a minimum distance of fifty (50) feet from any adjacent residential use property. Distance is measured from property line. An optional location for the refuse containers, to the one proposed is in the northwest area of the site, along the west perimeter, between the parking stalls oriented toward Cherry Avenue and the parking stalls oriented toward Mitchell Street.

3. Prior to development plan approval, provide attached 11 X 17 sheet(s), which are not part of the development plan pagination. Attached sheet(s) shall provide dimensioned building elevations, drawn to scale and in color. Sheet(s) to include color pallet to identify proposed colors by brand name and color code identification number.

4. Prior to development plan approval, sheet 5 of 5 shall remain black and white, however revise the sheet to identify all proposed colors to be used. Identify location of color(s) and by brand name and color identification code.

5. Prior development plan approval, revise landscape sheet L-1 to identify on the "Plan Schedule," the type of tree being proposed along the eastern perimeter, along Warren Avenue.
12/16/2011 PGEHLEN1 OTHER AGENCIES PIMA ASSN OF GOVTS Passed
12/16/2011 JANE DUARTE COT NON-DSD PARKS & RECREATION Approved
12/16/2011 ED ABRIGO PIMA COUNTY ASSESSOR Passed
12/16/2011 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved
12/16/2011 PGEHLEN1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Passed
12/16/2011 PGEHLEN1 COT NON-DSD TUCSON POLICE DEPARTMENT Passed
12/16/2011 ROBERT YOUNG PIMA COUNTY PIMA CTY - DEV REVIEW Passed
12/19/2011 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 2ND FL
TUCSON, AZ 85701-1207

AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: D11-0025 CATALINA CARE CENTER/DEVELOPMENT PLAN
DATE: December 19, 2011



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1. Correct the legal description. Should lot 9 be changed to a portion of lot 1?
12/21/2011 JWILLIA4 UTILITIES TUCSON ELECTRIC POWER Denied 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR#243810 December 21, 2011



Searer, Robbins and Stephens, Inc.
Attn: Jeff Stephens
5045 N 12th Street, Suite 111
Phoenix, Arizona 85014

Dear Mr. Stephens:

SUBJECT: Catalina Care Center
D11-0025

Tucson Electric Power Company (TEP) has reviewed the plan submitted November 16, 2011. TEP is unable to approve the plan at this time. There are existing electrical facilities within the boundaries of this project. In order for TEP to approve the plan the facilities and easements must be depicted on the plans.

*OH facilities and UG transformer appear to be in conflict.*

Enclosed is a copy of a TEP facility map showing the approximate location of the existing facilities. All costs associated with the relocation of the facilities in conflict will be billable to the developer.

Please resubmit two revised bluelines to City of Tucson for TEP’s review. You may contact the area Designer, Jennifer Crawford at 917-8708 should you have any questions.

Sincerely,



Elizabeth Miranda
Office Specialist

lm
Enclosure
cc: DSD_CDRC@Tucsonaz.gov, City of Tucson
J. Crawford, Tucson Electric Power
12/22/2011 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

December 22, 2011

David Robbins, NCARB
Searer, Robbins & Stephens, Inc.
5045 N. 12th Street # 111
Phoenix, Arizona 85014

Subject: D11-0025 CATALINA CARE CENTER Development Plan

Dear David:

Your submittal of July 29, 2011 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 9 DETAILED cover letters explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

9 Copies Revised Development Plan (Wastewater, Env Svcs, H/C Site, Zoning, Landscape, Engineering, Planning, Addressing, PDSD)

5 Copies Revised Landscape Plan (Landscape, Zoning, Engineering, Planning, PDSD)

2 Copies Revised Drainage Statement (Engineering, PDSD)

2 Copies Color Building Elevations (Planning, PDSD)

2 Copies Common Wall Agreement Documentation* (Landscape, PDSD)

1 Check Made out to “Pima County Treasurer” for $100.00 (Wastewater)
* If applicable

Should you have any questions, please call me at (520) 837-4893.

Sincerely,


John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/