Permit Number: D11-0013
Parcel: 12510025E

Review Status: Completed

Review Details: REVISION - DEV PLAN

Permit Number - D11-0013
Review Name: REVISION - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/12/2012 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/02/2012 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Quebedeaux Auto Dealership
Development Plan (Revision)
D11-0013

TRANSMITTAL DATE: August 3, 2012

DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The phasing calculations are not correct. Phase 1 should include all existing building square footages in the applicable calculations. The lot area that is currently being used should be included in the applicable calculations. Phase 2 should include all existing building square footages in the applicable calculations. The lot area that is currently being used should be included in the applicable calculations.

2. D.S. 2-01.3.9.H.5 Demonstrate on the plan how vehicles access is prevented for the Phase 3 area located in the southwest quadrant of the plan. There does not appear to be any barriers located south and west of the existing Detail Building (7).

3. D.S. 2-01.3.9.H.5.d The bicycle parking calculations are not correct. Per LUC Section 3.3.8.2.B, RETAIL TRADE USE GROUP, Construction Material Sales, Furniture, Carpet, or Appliance Store; Heavy Equipment Sales; and Vehicle Rental and Sales - Short-term required 2, Long-term 1 space per 12,000 sq. ft. GFA. Minimum requirement is 2 spaces. The Long-term bicycle parking calculation is based on gross floor area of all buildings on site.

4. D.S. 2-01.3.9.T The proposed dumpster enclosure called out under keynote 10 will need to be included in the phase 2 as the existing is scheduled to be relocated in phase 2.

5. D.S. 2-01.3.9.X The screen wall, landscape buffer and sidewalk required by re-zoning conditions 11, 16 and 23 will need to be in place by April 14, 2013 see re-zoning condition 8.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com

Sshield1 on DS1/planning/New Development Package/ D11-0013
08/08/2012 JOE LINVILLE LANDSCAPE REVIEW Denied The proposed phasing of the landscape and screening improvements may not be possible for areas reliant on the substitutions and modifications and related conditions approved per DDO-11-74. LUC 5.3.5.

Contact Russlyn Wells for additional information on obtaining an updated approval. 520-837-4948
08/09/2012 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied The review has been completed. Please make requested revisions and resubmit as required.

Final Status

Task End Date Reviewer's Name Type of Review Description
08/09/2012 CINDY AGUILAR OUT TO CUSTOMER Completed