| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/04/2011 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 10/07/2011 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
| 10/27/2011 | RONALD BROWN | HC SITE | REVIEW | Approved | |
| 10/28/2011 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | TO: Planning & Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Quebedeaux Auto Dealership Development Plan (2nd Review) D11-0013 TRANSMITTAL DATE: October 28, 2011 DUE DATE: November 1, 2011 DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Zoning Review Section conditionally approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements 2. Zoning acknowledges that a Development Standards Modification Request (DSMR) was approved. Provide the modifications that were granted within General Note 6. . If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com Sshield1 on DS1/planning/New Development Package/ D11-0013 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package. |
| 10/28/2011 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | PDSD LANDSCAPE 1) Provide reference to any approved code or standard modification or variance cases on all plan sheets, including the landscape plans in the lower right corner (in addition to in the general notes). 2) Provide verification, in writing, of any additional approvals obtained. Contact Gary Wittwer, DOT Landscape Architect for specific requirements and add the Standards for ROW landscaping to the plans. 3) Conditions of the DDO approval require final review of the plan by the DRB. Provide a copy of the final plan provided to the DRB. DDO-11-74. |
| 10/28/2011 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | Compliance with conditions verified. |
| 11/02/2011 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | TDOT has not object to the planting in ROW on this project. If you need more info let me know. Gary |
| 11/02/2011 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES November 2, 2011 Richard Cordova DOWL HKM 166 W. Alameda St. Tucson, Arizona 85701 Subject: D11-0013 QUEBEDEAUX AUTO DEALERSHIP Development Plan Dear Richard: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made, please submit the following documents for sign-off. 1 Rolled COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews. 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. Additional print copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City’s contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your prints to the CDRC office for sign-off approval. The printing company will deliver the original rolled prints to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. Plans will not be signed and released until the CDRC office has been notified by PC Addressing that all fees for this plan have been paid. The CDRC office will need this confirmation in writing. A Development Plan remains valid for a period of three (3) years from the date of approval. This Development Plan will expire on 11/02/14 per LUC 5.3.8.2.B. PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html. BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. Should you have any questions, please call me at 837-4893. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 882-8696 |