Permit Number: D11-0009
Parcel: 130140260

Address:
4050 E 22ND ST

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D11-0009
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/05/2011 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/11/2011 RONALD BROWN H/C SITE REVIEW Approved
08/15/2011 TERRY STEVENS ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: D11-0009
Fry's Fueling Center #17
Development Package

TRANSMITTAL: 08/29/11

DUE DATE: 09/07/11

COMMENTS:

1. The Zoning Review Section approves the development plan and grading plan for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements.



If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

TLS C:\planning\cdrc\developmentplan\D11-0009dpa.doc
08/25/2011 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 08/25/2011,

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering


SUBJECT: Fry's Fueling Center #17
D11-0009, T14S, R14E, SECTION 22

RECEIVED: Development Plan Package on August 05, 2011

The subject project has been reviewed. The project can not be approved at this time. Address the following comments before review can continue. Prepare a detailed response that explains the revisions that where made and references the exact location in the plan and in the Drainage Report where the revisions were made:

Drainage Report:

1. A Floodplain Use Permit and Elevation Certificate are required for the proposed work (i.e. all proposed work including the canopy, the kiosk, the drainage facilities, the drywell, the new pavement, etc.). Submit a Floodplain Use Permit Application with the next submittal.
2. Address drainage facilities maintenance responsibility and what needs to be done. Provide drainage facilities maintenance checklist. If this issue was addressed previously in the Drainage Report, point out the pages, where it was addressed.

General/Grading Notes:

1. Provide the drainage structures maintenance responsibility note in the General/Grading Notes sheet.


If you have any questions, I can be reached at 837-4933 or Laith.Alshami@tucsonaz.gov

RESUBMITTAL REQUIRED: Revised Development Plan Package
08/26/2011 JOE LINVILLE LANDSCAPE REVIEW Approved
08/26/2011 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: D11-0009 FRY’S FUELING CENTER #17/REVISED DEVELOPMENT PLAN
DATE: August 24, 2011



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.


Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar or bond paper of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.
08/31/2011 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

August 30, 2011

Dan Filuk
KDF Architectural Group
4001 N. 3rd St. # 130
Phoenix, AZ 85012

Subject: D11-0009 FRY’S FUEL CENTER #17 Development Package

Dear Dan:

Your submittal of April 13, 2011 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and 2 sets of the DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

2 Copies Revised Development Package (Engineering, PDSD)


Should you have any questions, please call me at 837-4893.

Sincerely,




John Williams
Planning Technician

All comments for this case are available on our website at http://www.tucsonaz.gov/dsd/

Via fax: (602) 234-1413
08/31/2011 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES
*** REVISED ***

August 30, 2011

Dan Filuk
KDF Architectural Group
4001 N. 3rd St. #130
Phoenix, AZ 85012

Subject: D11-0009 FRY’S FUEL CENTER #17 Development Package

Dear Dan:

The above referenced Development Package has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made, please submit the following documents for sign-off.

1 Rolled COMPLETE SET of the Development Package. Please include applicable sheets from any other concurrent reviews.

1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan (if applicable).

Additional print copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City’s contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your plans to the CDRC office for sign-off approval.

Plans will not be signed and released until the CDRC office has been notified by PC Addressing that all fees for this plan have been paid. The CDRC office will need this confirmation in writing.

A Development Package remains valid for a period of three (3) years from the date of approval. This Development Package will expire on 08/30/2014 per LUC 5.3.8.2.B.

PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION.

Should you have any questions, please call me at 837-4893.

Sincerely,



John Williams
Planning Technician

All comments for this case are available on our website at http://www.tucsonaz.gov/dsd/

Via fax: (602) 234-1413