Permit Review Detail
Review Status: Completed
Review Details: DEVELOPMENT PLAN
Permit Number - D10-0047
Review Name: DEVELOPMENT PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/03/2011 | DAVID MANN | COT NON-DSD | FIRE | Approved | |
| 01/03/2011 | RONALD BROWN | ADA | REVIEW | Passed | |
| 01/04/2011 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Approved | |
| 01/05/2011 | RONALD BROWN | ZONING HC | REVIEW | Approved | |
| 01/05/2011 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Brio Tuscan Grill @ Tucson Mall Development Plan (1st Review) D10-0047 TRANSMITTAL DATE: January 5, 2011 DUE DATE: January 13, 2011 DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is May 26, 2011. 2. This development plan was reviewed for full code compliance for the area of revision only. 3. D.S. 2-05.2.2.B.2 Provide the development plan number D10-0047 in the lower right corner of the plan. 4. D.S. 2-05.2.4.K Provide a width dimension for the proposed sidewalk located long the south side of the proposed building. Two (2) different dimensions are required as the sidewalk width varies. 5. D.S. 2-05.2.4.K As width dimensions were not provided for the southern sidewalk the following comment is based on information provided by Lisa Bowers, Metro Permit; the western portion of the southern sidewalk is 4.0' wide and the eastern portion of the southern sidewalk is 3.66'. Per D.S. 2-08.5.1.A All sidewalks will be a minimum four (4) feet wide. That said a approved Development Standards Modification Request (DSMR) is required to reduce the width of the sidewalk. The DSMR must be approved prior to approval of the development plan. If approved provide the following DSMR information on the development plan; DSMR Number, Date of Approval & what was approved. 6. D.S. 2-05.2.4.P Provide a dimension for the proposed wheel stops shown for the vehicle parking spaces shown along the southern side of the proposed building. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com Sshield1 on DS1/planning/New Development Package/ D10-0047 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan. |
| 01/06/2011 | FRODRIG2 | ENV SVCS | REVIEW | Approved | Date Case Number Project Address January 6, 2011 D10-0047 BRIO Tucson Grille DEVELOPMENT PLAN Comments: The proposed Development Plan for the BRIO Tucson Grille, Case No.D10-0047. Meets the minimum requirements for the Environmental Services, Solid Waste Disposal and Recycle Materials Standard 6-01, and is Approved. Environmental Services Department Development Plan Review Reviewer: Tony Teran Office Phone (520) 837-3706 E-mail: Tony.Teran @tucsonaz.gov |
| 01/06/2011 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES January 6, 2011 Jack Buchanan The WLB Group, Inc. 4444 East Broadway Blvd Tucson, Arizona 85711 Subject: D10-0047 Brio Tuscan Grille Development Plan Dear Jacke: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per the on-line comments, please submit the following documents for sign-off. 1 Rolled blue line COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews. 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. Additional black line copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. The printing company will deliver the original rolled blue line to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html. BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 881-7492 dpapproved |
| 12/29/2010 | JWILLIA4 | START | PLANS SUBMITTED | Completed |