Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D10-0040
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/04/2011 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 05/12/2011 | FERNE RODRIGUEZ | UTILITIES | TUCSON ELECTRIC POWER | Approved | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 WR# 231788 May 11, 2011 Holland AZ Investments 1515 N Academy #400 Colorado Springs, CO 80909 To Mr Holland : SUBJECT: Raphael Medical Plaza – 2nd Resubmittal D10-0040 Tucson Electric Power Company has reviewed and approved the development plan submitted May 6, 2011. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development. The new development plan shows the new gate opening on the west side of enclosure, in front of the opening of the existing transformer as requested in the original development plan. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. The customer is responsible for the new trenching to relocate them as well as the relocation cost. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Tucson Electric Power Company Attn: Rich Harrington New Business Project Manager P. O. Box 711 (DB-101) Tucson, AZ 85702 520-918-8726 Please call the area Designer Nancy DiMaria at (520) 918-8267, should you have any questions. Sincerely, Henrietta Noriega Office Specialist Design/Build hn Enclosures cc: City of Tucson (Email only) N. DiMaria Tucson Electric Power |
| 05/12/2011 | FERNE RODRIGUEZ | PIMA COUNTY | WASTEWATER | Approved | PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT 201 NORTH STONE AVENUE TUCSON, ARIZONA 85701-1207 JACKSON JENKINS PH: (520) 740-6500 DIRECTOR FAX: (520) 620-0135 May 11, 2011 To: GENE GOLDSTEIN BRAMIC DESIGN GROUP Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ____________________________________________ From: Tom Porter, Sr. CEA (520-740-6719), Pima County Regional Wastewater Reclamation Department Subject: RAPHAEL MEDICAL PLAZA 899 N WILMOT ROAD Dev. Plan - 3rd Submittal D10-0040 The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer collection lines for the above-referenced project. The following comments are offered for your use: The Pima County Regional Wastewater Reclamation Department hereby approves the above referenced submittal of the development plan as submitted. cc: Chad Amateau, PE Checked by:_________ Kristin Greene, PE, DLU Manager DLU Project folder |
| 05/16/2011 | FRODRIG2 | ENV SVCS | REVIEW | Approved | Date Case Number Project Address May 13, 2011 D10-0040 SAN RAPHAEL MEDICAL PLAZA DEVELOPMENT PLAN Comments: The proposed SAN RAPHAEL MEDICAL PLAZA Development plan, location at 899 N. Wilmot Rd. Case No.D10-0040 meets the minimum standard requirements for Environmental Services solid waste and recycle materials collection and is approved. Environmental Services Department Development Plan Review Reviewer: Tony Teran Office Phone (520) 837-3706 E-mail: Tony.Teran @tucsonaz.gov |
| 05/31/2011 | PAUL MACHADO | ENGINEERING | REVIEW | Approv-Cond | The project has been cond-approved upon correcting the discrepancy between the thickness of the conc. on the plan view (5") of the refuse enclosure and between section 10/3 (6"). 05-31-11. PM. |
| 05/31/2011 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | AUDREY FARENGA ADDRESSING REVIEW PH #: 740-6800 FAX #: 623-5411 TO: CITY PLANNING FROM: AUDREY FARENGA, ADDRESSING REVIEW SUBJECT: D10-0040 SAN RAPHAEL MEDICAL PLAZA/REVISED DEVELOPMENT PLAN DATE: May 31, 2011 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar or bond paper of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. 2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. |
| 06/01/2011 | RONALD BROWN | H/C SITE | REVIEW | Approved | |
| 06/01/2011 | STEVE SHIELDS | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: San Raphael Medical Plaza Development Plan (2nd Review) D10-0040 TRANSMITTAL DATE: June 1, 2011 DUE DATE: June 03, 2011 DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Zoning Review Section approves the development plan for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com Sshield1 on DS1/planning/New Development Package/ D10-0040 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan. |
| 06/06/2011 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | Please include a response letter with any submittals detailing revisions accomplished to address the following comments: An unpaved planting area, which is a minimum of thirty-four (34) square feet in area and four (4) feet in width, must be provided for each canopy tree. LUC 3.7.2.3 Revise the landscape plan to indicate the minimum width and square footage of tree planters in vehicular use areas. Planters are to be measured from the inside edge of tree planters. DS 2-07.2.2.A.2.e, LUC 3.7.2.3.A.1.c Show and identify existing plants to remain in place on the landscape plan. DS 2-07.2.2.A.1.e Submit the existing landscape plans for the site. If the expansion is less than twenty-five (25) percent, the requirements of this Division apply only to the proposed expansion. Existing development on the site is still subject to the zoning regulations in effect at the time the existing development received zoning approval. Show the existing landscape improvements on the plans. LUC 3.7.1.7 Revise the landscape plan to indicate the minimum width and square footage of tree planters in vehicular use areas. Planters are to be measured from the inside edge of tree planters. DS 2-07.2.2.A.2.e, LUC 3.7.2.3.A.1.c Provide additional canopy trees for any vehicular use area expansion as applicable. LUC 3.7.2.3. |
| 06/06/2011 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES June 6, 2011 Gene Goldstein Bramic Design Group 6255 N. Camino Pimema Alta #136 Tucson, Arizona 85718 Subject: D10-0040 SAN RAPHAEL MEDICAL PLAZA Development Plan Dear Gene: Your submittal of November 17, 2010 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 3 DETAILED cover letters explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 3 Copies Revised Development Plan (Landscape, Engineering, PDSD) 3 Copies Revised Landscape Plan (Landscape, Engineering, PDSD) 2 Copies Existing Landscape Plans (Landscape, PDSD) Should you have any questions, please call me at 837-4893. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: N/A; Sent by Email |