Permit Review Detail
Review Status: Completed
Review Details: REVISION - DEV PLAN
Permit Number - D10-0034
Review Name: REVISION - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/11/2011 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 05/18/2011 | DAVID MANN | COT NON-DSD | FIRE | Approved | |
| 05/19/2011 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | The cross sections and dimensions on sheet 26 must be revisd to include the new east west vehicular use area and the new 5th avenue alignment. |
| 05/19/2011 | JOHN BEALL | COT NON-DSD | COMMUNITY PLANNING | Approv-Cond | PLANNING AND DEVELOPMENT SERVICES DEPARTMENT COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D10-0034 The District: Development Package 5/19/11 () Tentative Plat (X) Development Plan (X) Landscape Plan () Revised Plan/Plat () Board of Adjustment (X) Other - Elevations CROSS REFERENCE: NEIGHBORHOOD PLAN: University Area Plan, West University Area Plan GATEWAY/SCENIC ROUTE: None COMMENTS DUE BY: 05/25/2011 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Rezoning (Special Exception) Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached (X) Conditionally Approved - 1) 1) Revise Section D-D on Sheet 26 of 29, to reflect new setback dimension and landscaping; and Section B-B to reflect parking. REVIEWER: JBeall 791-5505 DATE: 5/19/2011 |
| 05/19/2011 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 05/20/2011 | JWILLIA4 | PIMA COUNTY | WASTEWATER | Denied | PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT 201 NORTH STONE AVENUE TUCSON, ARIZONA 85701-1207 JACKSON JENKINS PH: (520) 740-6500 DIRECTOR FAX: (520) 620-0135 May 18, 2011 To: Tri Miller, PE Rick Engineering Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department __________________________ Prepared by: Chad Amateau, PE PCRWRD Checked by: _____ Subject: The District 550 North 5th Avenue Dev. Plan - 4th Submittal D10-0034 The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer collection lines for the above-referenced project. The following comments are offered for your use: 1. Revise plan to provide diagonal striping at all parking spaces contained within the public sewer easement. Label on the plan and provide a keynote that reads the following, " A sign shall be placed in front of the striped parking that reads. PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT MANHOLE IS LOCATED WITHIN A PUBLIC SEWER EASEMENT VEHICLES MAY BE TOWED This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the second(2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If the number of sheets changes, please adjust the review fee accordingly. cc: CC Patel, Development Services Tom Porter, CEA., PCRWRD Kristin Greene, PE, DLU Manager DLU Project folder |
| 05/20/2011 | JWILLIA4 | PIMA COUNTY | WASTEWATER | Denied | PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT 201 NORTH STONE AVENUE TUCSON, ARIZONA 85701-1207 JACKSON JENKINS PH: (520) 740-6500 DIRECTOR FAX: (520) 620-0135 June 7, 2011 To: Tri Miller, PE Rick Engineering Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department __________________________ Prepared by: Tom Porter, CEA., PCRWRD Subject: The District 550 North 5th Avenue Dev. Plan – 5th Submittal D10-0034 The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer collection lines for the above-referenced project. The following comments are offered for your use: The Pima County Regional Wastewater Reclamation Department hereby approves the above referenced submittal of the development plan as submitted. cc: CC Patel, Development Services Chad Amateau, PE PCRWRD Kristin Greene, PE, DLU Manager DLU Project folder |
| 05/24/2011 | RONALD BROWN | ZONING HC | REVIEW | Approved | |
| 05/24/2011 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approv-Cond | May 24, 2011 ACTIVITY NUMBER: D10-0034 PROJECT NAME: 5th Ave Student Housing PROJECT ADDRESS: 550 N 4th Avenue PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer Resubmittal Required: Traffic Engineering recommends a conditional approval of the Development Plan. After reviewing the revised development plan it is TDOT-Traffic's preference that the remaining portion of 5th Avenue public right of way (6th Street to 5th Street) be acquired by the developer or vacated to the developer by the City of Tucson. In an effort to avoid slowing down the approval process of the development plan TDOT-Traffic will entertain the idea of a real estate transaction handled through a separate instrument. The real estate transaction for 5th Avenue shall be finalized prior to the issuance of the first certificate of occupancy. In the event that the sell of the noted right of way exceeds $50,000 then TDOT-Traffic will lift the requirements for the right of way acquisition. If you have any questions, I can be reached at 837-6730 or Jose.Ortiz@tucsonaz.gov |
| 05/24/2011 | LAITH ALSHAMI | ENGINEERING | REVIEW | Denied | Laith Alshami, Engineering and Floodplain Review, 05/24/2011, TO: Patricia Gehlen FROM: Laith Alshami, P.E. CDRC Engineering SUBJECT: The District D10-0034, T14S, R13E, SECTION 12 RECEIVED: Development Plan Package on May 11, 2011 The subject project has been reviewed. The Development Package shall be approved once the following comments have been addressed properly: Cover Sheet: 1. The grading area has changed, but the cut and fill quantities were not revised. Verify that the quantities remained the same. Base Layer: 2. The angled parking space direction along the two-way P.A.A.L. might cause a conflict with vehicles crossing the oncoming traffic lane to park, and backing out into the oncoming traffic lane. It seems that the direction of the parking spaces should math the traffic direction. 3. It is not clear what is intended by the note "ROW Abandonment by Final Plat", shown on the west side of Fifth Avenue. Grading Plan: 4. Show all curb return radii. 5. Show the proposed screen wall, shown on the left side of Cross Section Detail C/12, completely inside the property line including the footing. If you have any questions, I can be reached at 837-4933 or Laith.Alshami@tucsonaz.gov |
| 05/25/2011 | JWILLIA4 | ENV SVCS | REVIEW | Approved | May 25, 2011 D10-0034 The District, Block 1 Development Plan Comments: The proposed Development Plan for the, The District Block 1, Development Case No.D10-0034, is acceptable to Environmental Services, Solid Waste Disposal and Recycle Materials Standard 6-01, and is Approved. Environmental Services Department Development Plan Review Reviewer: Tony Teran Office Phone (520) 837-3706 E-mail: Tony.Teran @tucsonaz.gov |
| 06/02/2011 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES May 26, 2011 Tri Miller Rick Engineering Co., Inc. 3945 E. Fort Lowell Rd. # 111 Tucson, Arizona 85712 Subject: D10-0034 THE DISTRICT Development Package Dear Tri: Your submittal of September 22, 2010 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and 6 sets of the DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 6 Copies Revised Development Package (Planning, Zoning, Wastewater, Traffic, Engineering, PDSD) Should you have any questions, please call me at 837-4893. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.tucsonaz.gov/dsd/ Via fax: (520) 322-6956 |
| 06/02/2011 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES *** REVISED *** June 2, 2011 Tri Miller Rick Engineering Co., Inc. 3945 E. Fort Lowell Rd. # 111 Tucson, Arizona 85712 Subject: D10-0034 THE DISTRICT Development Package Dear Tri: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made, please submit the following documents for sign-off. 1 Rolled blue line COMPLETE SET of the Development Package, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews. 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. Additional black line copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your plans to the CDRC office for sign-off approval. Plans will not be signed and released until the CDRC office has been notified by PC Addressing that all fees for this plan have been paid. The CDRC office will need this confirmation in writing PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. Should you have any questions, please call me at 837-4893. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.tucsonaz.gov/dsd/ Via fax: (520) 322-6956 |