Permit Number: D10-0033
Parcel: 14026041B

Address: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D10-0033
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/05/2010 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/22/2010 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
11/24/2010 JASON GREEN ENGINEERING REVIEW Approv-Cond DATE: November 24, 2010
SUBJECT: Country Club Commerce Center Development Plan Core Review- Engineering Review
TO: Patricia Gehlen, CDRC Manager
LOCATION: 5990 S Country Club Rd, T15S R14E Sec08 Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: D10-0033

SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the revised Development Plan Package, Drainage Statement (Cypress Civil Development, 10SEP10) and Stormwater Pollution Prevention Plan (Cypress Civil Development, 17SEP10). Engineering Division recommends conditional approval of the Development Plan Package at this time. This review falls under the draft policy for Development Plan Core Review, Development Standard 2-01. All comments reflect Development Plan, Grading Plan and SWPPP review. The following items need to be addressed prior to final approval through CDRC:

DEVELOPMENT PLAN:

1) Completed.
2) Completed.
3) Completed.

4) Restated: DS Sec.2-01.3.3: Revise the Development Plan Package to include the case number assigned to the project (D10-0033) on all sheets of the plan set. Sheets 1, 2, 6, 7, 8, 9, 10 and 11 do not reference the case number only Sheets 2, 3, and 12 do.

5) Acknowledged: DS Sec.2-01.3.7: However per DS 2-01 and the Development Plan submittal requirement the development plan document is to include all General Notes (Site and Grading, Paving Plan Notes) together on a separate page. The current proposal has the notes on 3 separate sheets. Prior approval from CDRC will be required due to the deviation from the standard.

6) Completed.

7) Restated: DS Sec.2-01.3.8.B: Provide the letters of approval from all entities that have a vested interest in the easements on site. Label the 10-foot trail easement that is delineated along the portion of the north side of the site.

8) Restated: DS Sec.2-01.3.8.C: Revise the development plan document to correctly dimension the right-of-way line from along the southern portion of the site. Currently the right-of-way is dimensioned to the trail easement line not the property line, revise.

9) Acknowledged.
10) Completed.
11) Completed.
12) Completed.
13) Completed.

STORMWATER POLLUTION PREVENTION PLAN:

14) The proposed SWPPP meets the minimum requirements of the AzPDES Construction General Permit (CGP). However the SWPPP and Exhibits can not be stamped approved until approval of the development plan documents.

15) Acknowledged.

DRAINAGE STATEMENT:

16) Acknowledged.


GENERAL COMMENTS:

Please provide a revised Development Plan Package that addresses the comments provided above. For any questions or to schedule meetings call me at 837-4929.


Jason Green, CFM
Senior Engineer Associate
Engineering Division
Planning & Development Services Department
12/06/2010 RONALD BROWN ZONING HC REVIEW Approved
12/08/2010 TERRY STEVENS ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: D10-0033
Country Club Commerce Center
Development Package

TRANSMITTAL: 12/08/2010

DUE DATE: 12/08/2010

COMMENTS:

1. The Zoning Review Section approves the development plan package for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements.


If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

TLS C:\planning\cdrc\developmentplan\D10-0033dpa.doc
12/10/2010 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES


December 10, 2010

Michael Schooler
GDA
250 S. Craycroft Rd # 200
Tucson, Arizona 85711

Subject: D10-0033 COUNTRY CLUB COMMERCE CENTER Development Package

Dear Michael:

The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per Engineering, please submit the following documents for sign-off.

1 Rolled blue line COMPLETE SET of the Development Package, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews.

1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan.

Additional black line copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your plans to the CDRC office for sign-off approval.

Plans will not be signed and released until the CDRC office has been notified by PC Addressing that all fees for this plan have been paid. The CDRC office will need this confirmation in writing

PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION.

Should you have any questions, please call me at 837-4893.
Sincerely,




John Williams
Planning Technician

All comments for this case are available on our website at http://www.tucsonaz.gov/dsd/

Via fax: (520) 881-4390
12/10/2010 JOE LINVILLE LANDSCAPE REVIEW Approved