| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/20/2010 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 09/21/2010 | RONALD BROWN | ZONING HC | REVIEW | Passed | |
| 09/21/2010 | DAVID MANN | COT NON-DSD | FIRE | Approved | |
| 09/27/2010 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Approved | >>> Douglas Kratina <DKratina@azdot.gov> 09/23/2010 12:42 PM >>> Regional Traffic Engineering has no comment on this submittal and recommends approval of this development. It will have no impact on any ADOT facilities. Thank you. Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments. . |
| 10/01/2010 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 2ND FL TUCSON, AZ 85701-1207 AUDREY FARENGA ADDRESSING REVIEW PH #: 740-6800 FAX #: 623-5411 TO: CITY PLANNING FROM: AUDREY FARENGA, ADDRESSING REVIEW SUBJECT: D10-0032 HOUGHTON ROAD AND BROADWAY BOULEVARD PARK AND RIDE/DEVELOPMENT PLAN DATE: September 30, 2010 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Shade the project location on the Vicinity Map. Include the section, township and range on all title blocks. Delete adjacent tax codes. Change Eastpoint Commercial Center MP Book 43 to Book 42 on all applicable sheets. |
| 10/04/2010 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Planning and Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Houghton Road & Broadway Blvd. Park & Ride Development Package (1st Review) D10-0032 TRANSMITTAL DATE: October 4, 2010 DUE DATE: October 15, 2010 DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development package. If, at the end of that time, the development package has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is June 30, 2011 2. This development package was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance. The following comments are based on the Development Package Submittal Requirements: 1. The drawing order does not follow the Development Package Submittal Requirements. The details should follow the grading plan and the SWPP should follow the landscape planting details. The following comments are based on the Development Standard 2-01.0: 1. D.S. 2-01.3.2.D Provide an administrative street address for the proposed Park & Ride adjacent to the title block. 2. D.S. 2-01.3.3. Provide the following relevant case numbers adjacent to the title block on each sheet, D03-002, SCZ-03-13, LS-03-53, S99-036, C10-99-55 & C9-83-09. 3. D.S. 2-01.3.7.A.3 List the rezoning conditions on sheet 2. 4. D.S. 2-01.3.7.A.4 At development designator "29" the General Note 3 next to the proposed use. 5. D.S. 2-01.3.7.A.6.b As a general note state "THIS PROJECT IS DESIGNED TO MEET THE OVERLAY ZONE(S) CRITERIA, SEC. 2.8.2, SCENIC CORRIDOR ZONE (SCZ); SEC. 2.8.3, MAJOR STREETS AND ROUTES (MS&R) SETBACK ZONE". For the SCZ provide the date of approval, what was approved, and conditions of approval. 6. D.S. 2-01.3.7.A.9.b Per Development Designator "28" & "29" lot coverage is not relevant. Provide a floor area ratio (FAR) that includes the allowed and proposed for the entire site. 7. D.S. 2-01.3.9.A As this project is comprised of three (3) parcels a lot combination is required. Provide a copy of the approved Pima County Combination Request Form with your next submittal. 8. D.S. 2-01.3.9.H.2 Show the existing sight visibility triangles (SVT's) on the plan. 9. D.S. 2-01.3.9.H.5 It appear that one-way parking area access lanes (PAALs) are proposed, clearly indicate on the plan how the one-way PAALS will be controlled, i.e. signage, pavement markings etc. 10. D.S. 2-01.3.9.H.5.a There are numerous areas on the plan where parking vehicles will over hang proposed sidewalks. Provide width dimensions for the sidewalks and if the proposed sidewalk adjacent to the vehicle parking space is less than 6.5 feet provide wheel stops to prevent parking vehicles from overhanging the sidewalk. 11. D.S. 2-01.3.9.H.5.a Provide a vehicle parking space calculation that encompasses the entire site. The calculation should include the number of required and provided. 12. D.S. 2-01.3.9.H.5.d The Class 2 bicycle parking detail shown on sheet 16 does not meet the requirements of D.S. 2-09.5.1.A, show the seventy-two (72) inch length per bicycle parking space on the detail. 13. D.S. 2-01.3.9.R There is an angled "ADA CROSS WALK STRIPING AREA", shown north of the seven (7) handicapped parking spaces located near the center of the project, due to safety issues this striped cross walk needs to run perpendicular to the PAAL. 14. If applicable ensure all changes are made to the grading and landscape plans. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com Sshield1 on DS1/planning/New Development Package/ D10-0032 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan. CDRC TRANSMITTAL TO: Planning and Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Houghton Road & Broadway Blvd. Park & Ride Development Package (1st Review) T10BU01438 TRANSMITTAL DATE: October 4, 2010 DUE DATE: October 15, 2010 GRADING PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning cannot approve the grading plan until the development package has been approved. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 10/08/2010 | FRODRIG2 | ENV SVCS | REVIEW | Denied | October 8, 2010 Due Date Case Number Project Address October 15, 2010 D10-0032 Houghton Road and Broadway Boulevard PARK AND RIDE DEVELOPMENT PLAN Comments: Denied, The proposed Development Plan for the Houghton Road and Broadway Boulevard, Case No.D10-0032. Dose not meets the minimum requirements for Environmental Services, Solid Waste Disposal Standard 6-01. The Plan must show provisions for both Solid Waste and Recycle collection. 1. All containers shown on Development Plans must be labeled for the intended use being Solid Waste or Recycle materials . 2. If the waste generated is proposed to be collect by the City of Tucson, Environmental Services Department.The type of containers proposed will need to be reviewed by ESD. Environmental Services Department Development Plan Review Reviewer: Tony Teran Office Phone (520) 837-3706 E-mail: Tony.Teran @tucsonaz.gov |
| 10/13/2010 | RONALD BROWN | ADA | REVIEW | Denied | 1. Please provide large scale sectional site plans as per Utility Plans, sheets 6 and 7 and include all construction reference notes. 2. On sheet 3, the note 3 reference to PC COT Std Dtl 207 is applicable only to accessible construction in the right of way. Please refer all ramps within the property boundaries to ADAAG, Section 4.7 and 4.8. a. Detectable warning strips for curb ramps may be 2' deep. 3. Insure all accessible routes comply with slope requirements of Section 4.3.2. Please show slope indicators of actual slopes on the site plan. 4. Please provide large scale details of all different types of ramps including detectable warning strips and reference to these details from the large scale site plans requested in comment 1 above. 5. The generic accessible parking plan detail shown on sheet 15 does not provide compliant access to the accessible route. a. Generic plans are not acceptable. Please provide a large scale detail of all the different types of accessible parking layouts as shown on sheet 3. b. Show all dimensions, aisles and widths, ramps or flush access to the accessible route, detectable warning strips, signage, "Van Accessible" parking, slopes and all other required accessible conditions as per ADAAG requirements foe accessible parking. 6. For the two grouped accessible spaces, how does one access the accessible route? 7. Ditto comment 6 for the 5 accessible parking spaces. 8. As per section 4.7.5, flared sides of curb ramps are only required where pedestrians may cross the ramp. Otherwise, return curbs may be used as per figure 12 (b). 9. Please provide a large scale detail of all the different types of sidewalk and curb ramp layouts as shown on sheet 3. a. Show all dimensions, widths, detectable warning strips, slopes and all other required accessible conditions as per ADAAG requirements for curb/sidewalk ramps Section 4.7 and 4.8. 10. Please provide a parking space analysis and show compliance with 4.1.2 (5). END OF COMMENTS |
| 10/14/2010 | FERNE RODRIGUEZ | COT NON-DSD | TUCSON POLICE DEPARTMENT | Denied | >>> Rebecca Noel 10/12/2010 5:04 PM >>> I have one concern about this project. Stated on attachment A page 3 of 3 #10 it reads that lights shall be as close to the ground as possible. How close is this? If the lights are placed too low they are susceptible to vandalism. They need to be placed at least 12 feet up to try and help prevent this. |
| 10/15/2010 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Submit 100% landscape plans. 2) Add the current and previous CDRC case numbers (rezoning, DP, Variance etc.)to the landscape plans. 3) Clarify how the site meets the conditions of rezoning or those of other cases. 4) The previous NPP and landscape mitigation plans may be applicable to this site and may affect the plant selection. Review the applicable approved plans and revise as necessary. |
| 10/18/2010 | TIM ROWE | PIMA COUNTY | WASTEWATER | Denied | PIMA COUNTY REGIONAL WASTEWATER RECLAMATION DEPARTMENT 201 NORTH STONE AVENUE TUCSON, ARIZONA 85701-1207 MICHAEL GRITZUK, P.E. PH: (520) 740-6500 DIRECTOR FAX: (520) 620-0135 October 18, 2010 To: Joesph Vaskovic Parsons Brinckerhoff Thru: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department ____________________________________________ From: Chad Amateau, PE , Civil Engineer, (520-740-6547), Pima County Regional Wastewater Reclamation Department Subject: Houghton Road and Broadway Boulevard Park & Ride Dev. Plan – 1st Submittal D10-0032 The Pima County Regional Wastewater Reclamation Department (PCRWRD) has received the plans for this project and per Arizona Revised Statues 32-125. (Seals for registrants) and Arizona Administrative Code R4-30-304. (Use of Seals) we are unable to conduct a plan review. Please resubmit plans signed and sealed by a professional registrant in the State of Arizona. Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $250.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If the number of sheets changes, please adjust the review fee accordingly. This comment letter has been reviewed and accepted for substantial conformance to Pima County Code Title 13 by: ___________________________ Chad Amateau, P.E., Civil Engineer PCRWRD, Planning Services Section, Development Liaison Unit cc: Tom Porter, Sr CEA Kristin Greene, PE, DLU Manager DLU Project folder |
| 10/18/2010 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | 4350 E. Irvington Road, Tucson, AZ 85714 Post Office Box 711, Tucson, AZ 85702 WR#229902 October 18, 2010 Dear Tom Fisher: SUBJECT: Houghton Rd / Broadway Blvd. Park & Ride D10-0032 Tucson Electric Power Company has reviewed and approved the development plan submitted October 1, 2010. All relocation costs or removal of existing TEP facilities will be billable to the customer. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Tucson Electric Power Company Attn: Richard Harrington New Business Project Manager P. O. Box 711 (DB-101) Tucson, AZ 85702 520-917-8726 Please call the area Designer Nancy DiMaria at (520) 918-8267, should you have any questions. Sincerely, Henrietta Noriega Office Specialist Design/Build hn Enclosures City of Tucson (Email only) cc:N. DiMaria |
| 10/18/2010 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | |
| 10/18/2010 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | October 18, 2010 D10-0032 1. Provide discharge quantities on the site plan and grading plans for all significant concentration points. 2. Remove the note indicating that the project is in a floodplain and floodplain use permits and/or elevation certificates will be required. |
| 10/19/2010 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES October 19, 2010 Joseph A. Vaskovic Parsons Brinckerhoff Quade & Douglas, Inc. 177 N. Church Avenue Tucson, Arizona 85701 Subject: D10-0032 HOUGHTON RD AND BROADWAY BLVD PARK AND RIDE Development Package Dear Joseph: Your submittal of September 15, 2010 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 8 DETAILED cover letters explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 8 Copies Revised Development Package (Zoning, Env Svcs, ADA, Tucson Police, Landscape, Wastewater, Engineering, PDSD) 2 Copies Copy of Approved Pima County Combo Request Form (Zoning, PDSD) 1 Check Made out to "Pima County Treasurer" for $250.00 (Wastewater) Should you have any questions, please call me at 837-4917. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 882-8830 |