Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D10-0020
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/02/2010 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/02/2010 | RONALD BROWN | ADA | REVIEW | Passed | Not a COT owned or operated property |
| 07/12/2010 | JASON GREEN | ENGINEERING | REVIEW | Approv-Cond | DATE: July 9, 2010 SUBJECT: Academy Del Sol Development Plan- 2nd Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 6740 S Santa Clara Ave, T15S R13E Sec14, Ward 1 REVIEWERS: Jason Green, CFM ACTIVITY: D10-0020 SUMMARY: Engineering Division of Planning Development Services Department has received and reviewed the proposed development plan. Engineering Division recommends conditional approval of the development plan at this time. The following item needs to be addressed prior to Final CDRC approval: DEVELOPMENT PLAN: 1) Complied. 2) Complied. 3) Complied. 4) Complied. 5) Complied. 6) Complied. 7) Complied. 8) Complied. 9) Complied. 10) Complied. 11) Complied. 12) DS Sec.2-05.2.3.I: Revise the development plan, Sheet 2, to correctly label the cross sections for the Water Surface Elevations (WSEL) as shown on the current effective FIRM Panel 04019C2238K refer to the Letter of Map Revision (LOMR) Case Number 99-09-1303P, effective date July 24, 2000 for the cross sections and water surface elevations based on NGVD29 datum. The cross sections shown on Sheet 2 appear to come from the proposed D-FIRM maps that are based on NAVD88 datum which have not been formally adopted by FEMA at this time. The WSEL sections must reflect the existing sections as shown on the referenced LOMR. 13) Acknowledged. 14) Complied. GENERAL COMMENTS: Please provide a revised development plan that addresses the comment provided above prior to Final CDRC approval. For any questions or to schedule meetings call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Planning & Development Services Department |
| 07/12/2010 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | CDRC Review Planning and Development Services Dept., Community Planning Review D10-0020, Academy del Sol, 2nd submittal Comments Due: 7/19/10 Items reviewed: Revised Development Plan Comments: The plans are approved. No resubmittal is required. Reviewed by: J. Hershenhorn, 7/8/10 F:\Shardir\UPDfiles\Development Review\CASE_REVIEW\CDRC\2010 Cases\D10-0020a.doc |
| 07/16/2010 | RONALD BROWN | ZONING HC | REVIEW | Approved | |
| 07/16/2010 | TERRY STEVENS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: D10-0020 Academy Del Sol Development Plan TRANSMITTAL: 07/16/2010 DUE DATE: 07/19/2010 COMMENTS: 1. The Zoning Review Section approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. 2. DS 2-01.3.1 The name, mailing and email addresses, and phone number of the developer of the project shall be provided. If the owner and the developer are the same list as owner/developer. 3. Lot coverage calculations must include vehicle use area for both uses. Example: Religious Use - Allowed Lot Coverage - 60% Provided Lot Coverage - Building area + all vehicle use area divided by lot square footage Educational Use - Allowed Lot Coverage - 15% Provided Lot Coverage - Building area + all vehicle use area divided by lot square footage Per LUC Sec. 3.2.2.2.B it appears that the least restrictive lot coverage will apply. Add a note stating such. Revise calculations. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 TLS C:\planning\cdrc\developmentplan\D10-0020dp-ca.doc |
| 07/19/2010 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) The landscape plans approved in 1998-1999 associated with the the Little League and soccer fields call for street borders along Basconia Avenue and Calle Medina. Identify these landscape borders on the Development Plan and show the specific improvements on the landscape plans. The plans proposed mesquite trees, Acacia redolens, an associated irrigation system, and decomposed granite between the fence and the sidewalk. 2) Revise General Note 3. LUC 3.7.2.4.A.2.d applies only to residential subdivisions of eight (8) or more lots. 3) The requirements for landscaping and screening at Calle Aragon and Santa Clara Ave. are documented in City Records on plans approved 11/81 (ref # 93-18). These requirements are the 5' high oleander screen, as depicted on the drawing, along with clear sight visibility triangles as was required at the time. (SVT's at that time approximate the current pedestrian SVT's in effect per the Development Standards.). |
| 07/20/2010 | JWILLIA4 | COT NON-DSD | TUCSON AIRPORT AUTHORITY | Approved | That said, I've been in communication with the developer and they'll be providing a copy of the recorded disclosure when its available. With this commitment the developer has satisfied TAA interests in the project and we do not object to COT CDRC development plan approval. Take care, Jordan D. Feld, CM, AICP Director of Planning Tucson Airport Authority 7005 S. Plumer Ave. Tucson, AZ 85756 |
| 07/20/2010 | JOHN WILLIAMS | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES July 20, 2010 Philip Carhuff Krebs Carhuff Architects 3149 E. Prince Road #151 Tucson, Arizona 85716 Subject: D10-0020 Academy Del Sol Development Plan Dear Philip: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per Landscaping, Zoning, and Engineering, please submit the following documents for sign-off. 1 Rolled blue line COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews. 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. Additional black line copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. The printing company will deliver the original rolled blue line to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html. BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. ** NOTICE *** The CDRC Office highly recommends that you show the revised plans to Joe Linville in Landscaping before you submit to the CDRC office for signature. Should you have any questions, please call me at 837-4917. Sincerely, John Williams Planning Technician All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (520) 577-4599 |